diff --git a/measures/emissions_reporting/measure.rb b/measures/emissions_reporting/measure.rb
index 86d24107e..e46ead8fa 100644
--- a/measures/emissions_reporting/measure.rb
+++ b/measures/emissions_reporting/measure.rb
@@ -204,7 +204,12 @@ def resources(model)
def enduses
enduses = [
+ 'Cooling',
'Heating',
+ # 'Fans',
+ # 'Pumps',
+ # 'HeatRejection',
+ # 'HeatRecovery',
'InteriorLights',
'ExteriorLights',
'InteriorEquipment',
@@ -217,12 +222,12 @@ def enduses
def hvac_uses
hvac_uses = [
- 'Heating',
'Cooling',
+ 'Heating',
'Fans',
'Pumps',
'HeatRejection',
- 'Humidification',
+ # 'Humidification',
'HeatRecovery'
]
return hvac_uses
@@ -301,27 +306,23 @@ def energyPlusOutputRequests(runner, user_arguments)
# add enduse meters
enduses.each do |enduse|
# lights, refrigeration only use electricity
- next if (enduse.include?("Lights") || enduse.include?("Refrigeration")) && resource != "Electricity"
+ next if (enduse.include?('Lights') || enduse.include?('Refrigeration')) && resource != 'Electricity'
result << OpenStudio::IdfObject.load("Output:Meter,#{enduse}:#{resource},#{frequency};").get
end
- # custom meters for hvac
+ # custom meters for HVAC
total_hvac_string = "Meter:Custom,TotalHVAC:#{resource},#{resource},"
-
- hvac_uses.each_with_index do |use,i|
- if hvac_uses.size == i+1
+
+ hvac_uses.each_with_index do |use, i|
+ if hvac_uses.size == i + 1
total_hvac_string << ",#{use}:#{resource};"
else
total_hvac_string << ",#{use}:#{resource},"
end
end
- cooling_string = "Meter:Custom,CoolingHVAC:#{resource},#{resource},,Cooling:#{resource},,HeatRejection:#{resource};"
-
result << OpenStudio::IdfObject.load(total_hvac_string).get
- result << OpenStudio::IdfObject.load(cooling_string).get
result << OpenStudio::IdfObject.load("Output:Meter,TotalHVAC:#{resource},#{frequency};").get
- result << OpenStudio::IdfObject.load("Output:Meter,CoolingHVAC:#{resource},#{frequency};").get
end
@@ -466,22 +467,19 @@ def run(runner, user_arguments)
return false
end
- # hourly_electricity_kwh = []
- hourly_electricity_mwh = []
- # electricity_values.each { |val| hourly_electricity_kwh << val * j_to_kwh }
- electricity_values.each { |val| hourly_electricity_mwh << val * j_to_mwh }
+ hourly_electricity_mwh = electricity_values.map{ |val| val * j_to_mwh }
# get end-use electricity values
electricity_enduse_results = {}
- enduses.push(["TotalHVAC","CoolingHVAC"]).flatten.each do |enduse|
+ enduses.push(['TotalHVAC']).flatten.each do |enduse|
electricity_enduse_results["#{enduse}_mwh"] = []
electricity_enduse_query = "SELECT VariableValue FROM ReportMeterData WHERE ReportMeterDataDictionaryIndex IN (SELECT ReportMeterDataDictionaryIndex from ReportMeterDataDictionary WHERE VariableType='Sum' AND upper(VariableName)='#{enduse.upcase}:ELECTRICITY' AND ReportingFrequency='Hourly' AND VariableUnits='J') AND TimeIndex IN (SELECT TimeIndex FROM Time WHERE EnvironmentPeriodIndex='#{env_period_ix}')"
- electricity_enduse_values = sqlFile.execAndReturnVectorOfDouble(electricity_enduse_query).get
+ electricity_enduse_values = sqlFile.execAndReturnVectorOfDouble(electricity_enduse_query).get.to_a
if electricity_enduse_values.empty?
runner.registerWarning("Unable to get hourly timeseries #{enduse} electricity use from the model. Cannot calculate results")
electricity_enduse_results["#{enduse}_mwh"] << 0
end
- electricity_enduse_values.each { |val| electricity_enduse_results["#{enduse}_mwh"] << val * j_to_mwh}
+ electricity_enduse_values.each { |val| electricity_enduse_results["#{enduse}_mwh"] << val * j_to_mwh }
end
# get run period natural gas values
@@ -522,8 +520,8 @@ def run(runner, user_arguments)
runner.registerValue('annual_propane_ghg_emissions_kg', annual_propane_emissions_co2e_kg)
# fuel end-use emissions
- enduses.push("TotalHVAC").each do |enduse|
- next if (enduse.include?("Lights") || enduse.include?("Refrigeration"))
+ enduses.push(['TotalHVAC']).flatten.each do |enduse|
+ next if (enduse.include?('Lights') || enduse.include?('Refrigeration'))
# get run period natural gas end-use values
gas_enduse_query = "SELECT VariableValue FROM ReportMeterData WHERE ReportMeterDataDictionaryIndex IN (SELECT ReportMeterDataDictionaryIndex from ReportMeterDataDictionary WHERE VariableType='Sum' AND upper(VariableName)='#{enduse.upcase}:#{gas.upcase}' AND ReportingFrequency='Run Period' AND VariableUnits='J') AND TimeIndex IN (SELECT TimeIndex FROM Time WHERE EnvironmentPeriodIndex='#{env_period_ix}')"
diff --git a/measures/emissions_reporting/measure.xml b/measures/emissions_reporting/measure.xml
index a66d6c937..bed61289d 100644
--- a/measures/emissions_reporting/measure.xml
+++ b/measures/emissions_reporting/measure.xml
@@ -3,8 +3,8 @@
3.1
emissions_reporting
acdba906-e08f-4c88-9aef-2f0b0cfbb9d1
- 54d34e1c-f449-4e57-83ec-e2e5bbff062a
- 2024-06-20T18:59:02Z
+ 9e9bc9bb-88ce-420e-864f-77cbdaf1d4b6
+ 2024-10-14T14:42:11Z
C46EF23F
EmissionsReporting
Emissions Reporting
@@ -489,7 +489,7 @@
measure.rb
rb
script
- D1F6C156
+ F4929A45
cambium/AER_95DecarbBy2035_1/AZNMc.csv
@@ -735,481 +735,481 @@
cambium/AER_HighRECost_1/AZNMc.csv
csv
resource
- D4C95721
+ E9926239
cambium/AER_HighRECost_1/CAMXc.csv
csv
resource
- 3EF7F26E
+ A1505F59
cambium/AER_HighRECost_1/ERCTc.csv
csv
resource
- 4D30BA21
+ 65D6D053
cambium/AER_HighRECost_1/FRCCc.csv
csv
resource
- 42A29C80
+ 0934DC30
cambium/AER_HighRECost_1/MROEc.csv
csv
resource
- 46D68A6B
+ BBA03091
cambium/AER_HighRECost_1/MROWc.csv
csv
resource
- A05A5981
+ 1DCBACCC
cambium/AER_HighRECost_1/NEWEc.csv
csv
resource
- C33EC2DC
+ C91F8972
cambium/AER_HighRECost_1/NWPPc.csv
csv
resource
- 0D213EB3
+ D9C6FE22
cambium/AER_HighRECost_1/NYSTc.csv
csv
resource
- 413CF585
+ CF1BD173
cambium/AER_HighRECost_1/RFCEc.csv
csv
resource
- BAFD4D8B
+ B243D258
cambium/AER_HighRECost_1/RFCMc.csv
csv
resource
- 3E616C06
+ 5B4C620C
cambium/AER_HighRECost_1/RFCWc.csv
csv
resource
- 2C9DDAC8
+ 8DBA5522
cambium/AER_HighRECost_1/RMPAc.csv
csv
resource
- 9529DCD4
+ E24308F7
cambium/AER_HighRECost_1/SPNOc.csv
csv
resource
- 6DBE337A
+ AD37E3CB
cambium/AER_HighRECost_1/SPSOc.csv
csv
resource
- 2C0F00D1
+ A9E2636C
cambium/AER_HighRECost_1/SRMVc.csv
csv
resource
- 896EC08A
+ C951D885
cambium/AER_HighRECost_1/SRMWc.csv
csv
resource
- 7D3E80BE
+ 6A855AAD
cambium/AER_HighRECost_1/SRSOc.csv
csv
resource
- A0D2CA5D
+ C1E4DD05
cambium/AER_HighRECost_1/SRTVc.csv
csv
resource
- D678ACFB
+ 95F24165
cambium/AER_HighRECost_1/SRVCc.csv
csv
resource
- 5D5FC6D9
+ F195E3E7
cambium/AER_LowRECost_1/AZNMc.csv
csv
resource
- 3A37AD29
+ 8C32359A
cambium/AER_LowRECost_1/CAMXc.csv
csv
resource
- 687DC844
+ 35A223FD
cambium/AER_LowRECost_1/ERCTc.csv
csv
resource
- 32706FAB
+ 0A1036FC
cambium/AER_LowRECost_1/FRCCc.csv
csv
resource
- 8732F796
+ C1EC7C27
cambium/AER_LowRECost_1/MROEc.csv
csv
resource
- CFAFA1EA
+ 724B55A8
cambium/AER_LowRECost_1/MROWc.csv
csv
resource
- BEBCDC4D
+ 7E74E897
cambium/AER_LowRECost_1/NEWEc.csv
csv
resource
- 23E83CD2
+ 986EF6CE
cambium/AER_LowRECost_1/NWPPc.csv
csv
resource
- 3BED6599
+ 518E8C74
cambium/AER_LowRECost_1/NYSTc.csv
csv
resource
- E514BD97
+ 3CF6C443
cambium/AER_LowRECost_1/RFCEc.csv
csv
resource
- FF8B42A1
+ 8B6402DB
cambium/AER_LowRECost_1/RFCMc.csv
csv
resource
- 70A98454
+ 55307BA8
cambium/AER_LowRECost_1/RFCWc.csv
csv
resource
- AF00FC95
+ ED0EB98C
cambium/AER_LowRECost_1/RMPAc.csv
csv
resource
- 20847AA3
+ 0CC0C83A
cambium/AER_LowRECost_1/SPNOc.csv
csv
resource
- 8E254DFA
+ 7C6F6516
cambium/AER_LowRECost_1/SPSOc.csv
csv
resource
- 8B6FF834
+ EAEF6312
cambium/AER_LowRECost_1/SRMVc.csv
csv
resource
- 62EBA138
+ 5C814639
cambium/AER_LowRECost_1/SRMWc.csv
csv
resource
- E4D79F33
+ A537A0AC
cambium/AER_LowRECost_1/SRSOc.csv
csv
resource
- 02A3237F
+ FCE1A3EE
cambium/AER_LowRECost_1/SRTVc.csv
csv
resource
- A8468F66
+ 6F4D82CD
cambium/AER_LowRECost_1/SRVCc.csv
csv
resource
- 85888A65
+ 0E18B327
cambium/AER_MidCase_1/AZNMc.csv
csv
resource
- 551BC76F
+ 9C27DC9D
cambium/AER_MidCase_1/CAMXc.csv
csv
resource
- 24C70790
+ BD267434
cambium/AER_MidCase_1/ERCTc.csv
csv
resource
- E2D6716E
+ 2D08E3E9
cambium/AER_MidCase_1/FRCCc.csv
csv
resource
- F0FB9355
+ ADFE16CA
cambium/AER_MidCase_1/MROEc.csv
csv
resource
- FBF27D1D
+ 9F798025
cambium/AER_MidCase_1/MROWc.csv
csv
resource
- 7FBE7A36
+ 78522923
cambium/AER_MidCase_1/NEWEc.csv
csv
resource
- 4752F7B0
+ C8C8D55D
cambium/AER_MidCase_1/NWPPc.csv
csv
resource
- B802B114
+ F50615DC
cambium/AER_MidCase_1/NYSTc.csv
csv
resource
- 003B9D3A
+ 4C1FAFB3
cambium/AER_MidCase_1/RFCEc.csv
csv
resource
- 47B85E9B
+ C776466D
cambium/AER_MidCase_1/RFCMc.csv
csv
resource
- AE21184F
+ 6B08767D
cambium/AER_MidCase_1/RFCWc.csv
csv
resource
- B687918F
+ E3B19516
cambium/AER_MidCase_1/RMPAc.csv
csv
resource
- D99FCF9C
+ 7F8BA753
cambium/AER_MidCase_1/SPNOc.csv
csv
resource
- B3C3064E
+ 5F3A85C0
cambium/AER_MidCase_1/SPSOc.csv
csv
resource
- 96A5FF75
+ F42E4898
cambium/AER_MidCase_1/SRMVc.csv
csv
resource
- F7F551F5
+ 9DBDE969
cambium/AER_MidCase_1/SRMWc.csv
csv
resource
- 204620BE
+ BC5E29C5
cambium/AER_MidCase_1/SRSOc.csv
csv
resource
- 84FE0DCA
+ BEE9C83A
cambium/AER_MidCase_1/SRTVc.csv
csv
resource
- CDBE030C
+ F4A7B254
cambium/AER_MidCase_1/SRVCc.csv
csv
resource
- 3090BA0A
+ A3BE659D
cambium/LRMER_95DecarbBy2035_15/AZNMc.csv
csv
resource
- EA65DBB5
+ 4ADBE6A8
cambium/LRMER_95DecarbBy2035_15/CAMXc.csv
csv
resource
- 2AE28113
+ 761778F3
cambium/LRMER_95DecarbBy2035_15/ERCTc.csv
csv
resource
- 3075D4C3
+ D7CBF78B
cambium/LRMER_95DecarbBy2035_15/FRCCc.csv
csv
resource
- FD988D29
+ 13D1AEDF
cambium/LRMER_95DecarbBy2035_15/MROEc.csv
csv
resource
- FEFD506F
+ 4AA536BA
cambium/LRMER_95DecarbBy2035_15/MROWc.csv
csv
resource
- AB6FF811
+ 8CC2E3B5
cambium/LRMER_95DecarbBy2035_15/NEWEc.csv
csv
resource
- C22492A9
+ 0F047A2D
cambium/LRMER_95DecarbBy2035_15/NWPPc.csv
csv
resource
- 1F9BF620
+ A90A63AC
cambium/LRMER_95DecarbBy2035_15/NYSTc.csv
csv
resource
- 4BCDCE09
+ 13A192ED
cambium/LRMER_95DecarbBy2035_15/RFCEc.csv
csv
resource
- 743D11B0
+ 27C3694B
cambium/LRMER_95DecarbBy2035_15/RFCMc.csv
csv
resource
- 18736F4A
+ 9D300015
cambium/LRMER_95DecarbBy2035_15/RFCWc.csv
csv
resource
- 77FC3CA5
+ D3F68BBF
cambium/LRMER_95DecarbBy2035_15/RMPAc.csv
csv
resource
- B407F67E
+ 196789FB
cambium/LRMER_95DecarbBy2035_15/SPNOc.csv
csv
resource
- 8FABB683
+ A1DF9AEF
cambium/LRMER_95DecarbBy2035_15/SPSOc.csv
csv
resource
- C137177B
+ A4DCDB8B
cambium/LRMER_95DecarbBy2035_15/SRMVc.csv
csv
resource
- 1EB3EC6D
+ 51F330FF
cambium/LRMER_95DecarbBy2035_15/SRMWc.csv
csv
resource
- 1D7A027F
+ 5C672EAB
cambium/LRMER_95DecarbBy2035_15/SRSOc.csv
csv
resource
- 8EE207CD
+ 321D34CA
cambium/LRMER_95DecarbBy2035_15/SRTVc.csv
csv
resource
- 050CDC05
+ BB02BE24
cambium/LRMER_95DecarbBy2035_15/SRVCc.csv
csv
resource
- C55028AD
+ FD8BB131
cambium/LRMER_95DecarbBy2035_15_2025start/AZNMc.csv
@@ -1455,721 +1455,721 @@
cambium/LRMER_95DecarbBy2035_30/AZNMc.csv
csv
resource
- 617EA867
+ 1B3B933D
cambium/LRMER_95DecarbBy2035_30/CAMXc.csv
csv
resource
- BB2E5BE3
+ 4310FD11
cambium/LRMER_95DecarbBy2035_30/ERCTc.csv
csv
resource
- 1B8D7884
+ CEB3D7C7
cambium/LRMER_95DecarbBy2035_30/FRCCc.csv
csv
resource
- EEAAE3B8
+ 733CE95A
cambium/LRMER_95DecarbBy2035_30/MROEc.csv
csv
resource
- D973B5D5
+ 08317C10
cambium/LRMER_95DecarbBy2035_30/MROWc.csv
csv
resource
- 6AB8A0AC
+ 7F49E93D
cambium/LRMER_95DecarbBy2035_30/NEWEc.csv
csv
resource
- 893B631D
+ A6049F33
cambium/LRMER_95DecarbBy2035_30/NWPPc.csv
csv
resource
- EA68D95C
+ 94FBEE7F
cambium/LRMER_95DecarbBy2035_30/NYSTc.csv
csv
resource
- D83AAB4A
+ 4DF6C1EC
cambium/LRMER_95DecarbBy2035_30/RFCEc.csv
csv
resource
- A48BD49D
+ B6B460C9
cambium/LRMER_95DecarbBy2035_30/RFCMc.csv
csv
resource
- 291DEBC3
+ 459808BE
cambium/LRMER_95DecarbBy2035_30/RFCWc.csv
csv
resource
- D6A5EB54
+ C7D06A51
cambium/LRMER_95DecarbBy2035_30/RMPAc.csv
csv
resource
- C38D57E0
+ 9F1DA8F4
cambium/LRMER_95DecarbBy2035_30/SPNOc.csv
csv
resource
- 8B09BA73
+ B0C194AB
cambium/LRMER_95DecarbBy2035_30/SPSOc.csv
csv
resource
- EB5AB5DC
+ 60C5212E
cambium/LRMER_95DecarbBy2035_30/SRMVc.csv
csv
resource
- B50906A0
+ F8582563
cambium/LRMER_95DecarbBy2035_30/SRMWc.csv
csv
resource
- BDC86E04
+ B43B1BF3
cambium/LRMER_95DecarbBy2035_30/SRSOc.csv
csv
resource
- 78C6E192
+ 916B188B
cambium/LRMER_95DecarbBy2035_30/SRTVc.csv
csv
resource
- 1D152C4D
+ 375F0ABF
cambium/LRMER_95DecarbBy2035_30/SRVCc.csv
csv
resource
- 6D351ACE
+ B0B482D8
cambium/LRMER_95DecarbBy2050_15/AZNMc.csv
csv
resource
- 02A825D3
+ 6FE6D867
cambium/LRMER_95DecarbBy2050_15/CAMXc.csv
csv
resource
- 8E174CCE
+ 28444B22
cambium/LRMER_95DecarbBy2050_15/ERCTc.csv
csv
resource
- 910F15FC
+ FA07D7E4
cambium/LRMER_95DecarbBy2050_15/FRCCc.csv
csv
resource
- E975C927
+ 2451512E
cambium/LRMER_95DecarbBy2050_15/MROEc.csv
csv
resource
- 10339876
+ AF60B1DD
cambium/LRMER_95DecarbBy2050_15/MROWc.csv
csv
resource
- AB998BBF
+ EEE3AE44
cambium/LRMER_95DecarbBy2050_15/NEWEc.csv
csv
resource
- C32B1367
+ 7629EB28
cambium/LRMER_95DecarbBy2050_15/NWPPc.csv
csv
resource
- 01EEF386
+ CE243BAF
cambium/LRMER_95DecarbBy2050_15/NYSTc.csv
csv
resource
- 4E2C0D6D
+ 43424395
cambium/LRMER_95DecarbBy2050_15/RFCEc.csv
csv
resource
- E8098B59
+ 798C3394
cambium/LRMER_95DecarbBy2050_15/RFCMc.csv
csv
resource
- 918AE721
+ 043C2406
cambium/LRMER_95DecarbBy2050_15/RFCWc.csv
csv
resource
- 1027037D
+ 5A5F3451
cambium/LRMER_95DecarbBy2050_15/RMPAc.csv
csv
resource
- 0E0DEA6D
+ 9C0BC893
cambium/LRMER_95DecarbBy2050_15/SPNOc.csv
csv
resource
- 3B843CC0
+ E90BF12C
cambium/LRMER_95DecarbBy2050_15/SPSOc.csv
csv
resource
- 393665F8
+ 82F8A9A3
cambium/LRMER_95DecarbBy2050_15/SRMVc.csv
csv
resource
- 8DC56000
+ 8A7646CC
cambium/LRMER_95DecarbBy2050_15/SRMWc.csv
csv
resource
- F41F3A3E
+ B03EC737
cambium/LRMER_95DecarbBy2050_15/SRSOc.csv
csv
resource
- 420051A3
+ AD50FF23
cambium/LRMER_95DecarbBy2050_15/SRTVc.csv
csv
resource
- D713FE33
+ DDA1F418
cambium/LRMER_95DecarbBy2050_15/SRVCc.csv
csv
resource
- 20B51B42
+ CE2168F3
cambium/LRMER_95DecarbBy2050_30/AZNMc.csv
csv
resource
- C44DDD6C
+ 77992995
cambium/LRMER_95DecarbBy2050_30/CAMXc.csv
csv
resource
- BDF06EA2
+ 76F82285
cambium/LRMER_95DecarbBy2050_30/ERCTc.csv
csv
resource
- 2A253C38
+ F66EDDA3
cambium/LRMER_95DecarbBy2050_30/FRCCc.csv
csv
resource
- 33520D7E
+ 6DAB2566
cambium/LRMER_95DecarbBy2050_30/MROEc.csv
csv
resource
- 2F7E0A84
+ 2C45566E
cambium/LRMER_95DecarbBy2050_30/MROWc.csv
csv
resource
- 614B5F52
+ 5FD2CE7F
cambium/LRMER_95DecarbBy2050_30/NEWEc.csv
csv
resource
- 47A7268F
+ 1C459FC1
cambium/LRMER_95DecarbBy2050_30/NWPPc.csv
csv
resource
- D7D56D1B
+ B37400E4
cambium/LRMER_95DecarbBy2050_30/NYSTc.csv
csv
resource
- A7CF2050
+ CAC62147
cambium/LRMER_95DecarbBy2050_30/RFCEc.csv
csv
resource
- B85141FB
+ 16D0A839
cambium/LRMER_95DecarbBy2050_30/RFCMc.csv
csv
resource
- D7D2FDA3
+ 51DA6D1F
cambium/LRMER_95DecarbBy2050_30/RFCWc.csv
csv
resource
- 2080C368
+ D5CC2540
cambium/LRMER_95DecarbBy2050_30/RMPAc.csv
csv
resource
- 25CFBFAA
+ 94962B7C
cambium/LRMER_95DecarbBy2050_30/SPNOc.csv
csv
resource
- D7CCA754
+ 863A9C47
cambium/LRMER_95DecarbBy2050_30/SPSOc.csv
csv
resource
- E2ABB0E4
+ 74DB4257
cambium/LRMER_95DecarbBy2050_30/SRMVc.csv
csv
resource
- D800299C
+ 512549DD
cambium/LRMER_95DecarbBy2050_30/SRMWc.csv
csv
resource
- F22A6E12
+ C81A3722
cambium/LRMER_95DecarbBy2050_30/SRSOc.csv
csv
resource
- 4D954FE1
+ C478B21C
cambium/LRMER_95DecarbBy2050_30/SRTVc.csv
csv
resource
- 1AB966D2
+ 6A940DD3
cambium/LRMER_95DecarbBy2050_30/SRVCc.csv
csv
resource
- F8DA3129
+ 30785FDF
cambium/LRMER_HighRECost_15/AZNMc.csv
csv
resource
- 10F4979B
+ BA6FFEEA
cambium/LRMER_HighRECost_15/CAMXc.csv
csv
resource
- 06B8E3A9
+ EF6E459F
cambium/LRMER_HighRECost_15/ERCTc.csv
csv
resource
- F0A6BD6C
+ 033E2B83
cambium/LRMER_HighRECost_15/FRCCc.csv
csv
resource
- 209A8A78
+ E3CCD634
cambium/LRMER_HighRECost_15/MROEc.csv
csv
resource
- CDB99E90
+ 65022053
cambium/LRMER_HighRECost_15/MROWc.csv
csv
resource
- 2236BEDF
+ 8954C589
cambium/LRMER_HighRECost_15/NEWEc.csv
csv
resource
- A169F0E9
+ D3408395
cambium/LRMER_HighRECost_15/NWPPc.csv
csv
resource
- D7D27B81
+ BED1CB5C
cambium/LRMER_HighRECost_15/NYSTc.csv
csv
resource
- 6A06E501
+ AA7D65F5
cambium/LRMER_HighRECost_15/RFCEc.csv
csv
resource
- 1F77934A
+ DCC35CB5
cambium/LRMER_HighRECost_15/RFCMc.csv
csv
resource
- 068E0BF6
+ AEB548CD
cambium/LRMER_HighRECost_15/RFCWc.csv
csv
resource
- DA8DCDD1
+ B669944A
cambium/LRMER_HighRECost_15/RMPAc.csv
csv
resource
- 25639346
+ A62B2C47
cambium/LRMER_HighRECost_15/SPNOc.csv
csv
resource
- 595A9F0E
+ 0A86C979
cambium/LRMER_HighRECost_15/SPSOc.csv
csv
resource
- FC272E34
+ A709DA54
cambium/LRMER_HighRECost_15/SRMVc.csv
csv
resource
- DE088C7D
+ 73A63F08
cambium/LRMER_HighRECost_15/SRMWc.csv
csv
resource
- ECC15A07
+ 61C7DCA7
cambium/LRMER_HighRECost_15/SRSOc.csv
csv
resource
- D2E928CD
+ B5C8BF9D
cambium/LRMER_HighRECost_15/SRTVc.csv
csv
resource
- F9407685
+ 0C6BDA8F
cambium/LRMER_HighRECost_15/SRVCc.csv
csv
resource
- 11505B53
+ 7A5E9E5A
cambium/LRMER_HighRECost_30/AZNMc.csv
csv
resource
- 42067BE2
+ C26C83AD
cambium/LRMER_HighRECost_30/CAMXc.csv
csv
resource
- 0827DEF2
+ 8187C349
cambium/LRMER_HighRECost_30/ERCTc.csv
csv
resource
- 9B0DA457
+ 38932096
cambium/LRMER_HighRECost_30/FRCCc.csv
csv
resource
- 2D7A54B8
+ 89F08235
cambium/LRMER_HighRECost_30/MROEc.csv
csv
resource
- 805B99C1
+ 476226D9
cambium/LRMER_HighRECost_30/MROWc.csv
csv
resource
- 92F47632
+ C2349B92
cambium/LRMER_HighRECost_30/NEWEc.csv
csv
resource
- 4E67CE8D
+ F654A6C4
cambium/LRMER_HighRECost_30/NWPPc.csv
csv
resource
- C34A5A98
+ 57D04BF8
cambium/LRMER_HighRECost_30/NYSTc.csv
csv
resource
- 71D4CC07
+ B40F4302
cambium/LRMER_HighRECost_30/RFCEc.csv
csv
resource
- 79295FE3
+ 9A84F8F3
cambium/LRMER_HighRECost_30/RFCMc.csv
csv
resource
- A408E408
+ 5FB34230
cambium/LRMER_HighRECost_30/RFCWc.csv
csv
resource
- 29417D91
+ 7D8DD7C9
cambium/LRMER_HighRECost_30/RMPAc.csv
csv
resource
- 13AC7307
+ EF4712A0
cambium/LRMER_HighRECost_30/SPNOc.csv
csv
resource
- 64765D5B
+ EBD62FDC
cambium/LRMER_HighRECost_30/SPSOc.csv
csv
resource
- 1FDBDE82
+ 26F7506C
cambium/LRMER_HighRECost_30/SRMVc.csv
csv
resource
- 2AB0CAB1
+ 6527EDBE
cambium/LRMER_HighRECost_30/SRMWc.csv
csv
resource
- 12D5F730
+ 718C17AA
cambium/LRMER_HighRECost_30/SRSOc.csv
csv
resource
- 9BD02CEA
+ 1037791A
cambium/LRMER_HighRECost_30/SRTVc.csv
csv
resource
- F65DF2C5
+ 602FEF18
cambium/LRMER_HighRECost_30/SRVCc.csv
csv
resource
- 42F30D01
+ D0ABCEFE
cambium/LRMER_LowRECost_15/AZNMc.csv
csv
resource
- A6D2870C
+ 33C0B242
cambium/LRMER_LowRECost_15/CAMXc.csv
csv
resource
- 3F2433DD
+ B0CDEA00
cambium/LRMER_LowRECost_15/ERCTc.csv
csv
resource
- 06E9DD46
+ B2EF6279
cambium/LRMER_LowRECost_15/FRCCc.csv
csv
resource
- 4096B7FF
+ 10B77FAB
cambium/LRMER_LowRECost_15/MROEc.csv
csv
resource
- E676139E
+ F6C705FE
cambium/LRMER_LowRECost_15/MROWc.csv
csv
resource
- 15303B74
+ DA375A6E
cambium/LRMER_LowRECost_15/NEWEc.csv
csv
resource
- B7849446
+ 6997A24D
cambium/LRMER_LowRECost_15/NWPPc.csv
csv
resource
- A1AAF7B1
+ 516DECD3
cambium/LRMER_LowRECost_15/NYSTc.csv
csv
resource
- F46FDD27
+ C3335A44
cambium/LRMER_LowRECost_15/RFCEc.csv
csv
resource
- FC4B5728
+ B2C0ABEB
cambium/LRMER_LowRECost_15/RFCMc.csv
csv
resource
- 6D7A3A14
+ 989D16AF
cambium/LRMER_LowRECost_15/RFCWc.csv
csv
resource
- 9D57FE39
+ 6206AAF9
cambium/LRMER_LowRECost_15/RMPAc.csv
csv
resource
- 46541F00
+ 677812AA
cambium/LRMER_LowRECost_15/SPNOc.csv
csv
resource
- 34D2C692
+ 3FB2B474
cambium/LRMER_LowRECost_15/SPSOc.csv
csv
resource
- 015CEB38
+ 44C40B0F
cambium/LRMER_LowRECost_15/SRMVc.csv
csv
resource
- BB56B36A
+ E2322C06
cambium/LRMER_LowRECost_15/SRMWc.csv
csv
resource
- C22473F2
+ EA82AF83
cambium/LRMER_LowRECost_15/SRSOc.csv
csv
resource
- CED585CC
+ 0AB813C0
cambium/LRMER_LowRECost_15/SRTVc.csv
csv
resource
- C4A9D3C2
+ 328EEEA6
cambium/LRMER_LowRECost_15/SRVCc.csv
csv
resource
- 8D014077
+ 6F7D8750
cambium/LRMER_LowRECost_15_2025start/AZNMc.csv
@@ -2415,241 +2415,241 @@
cambium/LRMER_LowRECost_30/AZNMc.csv
csv
resource
- B4C49BAA
+ 58356445
cambium/LRMER_LowRECost_30/CAMXc.csv
csv
resource
- 0F65FF63
+ 989D5237
cambium/LRMER_LowRECost_30/ERCTc.csv
csv
resource
- 3BCBD2B8
+ C804ADEB
cambium/LRMER_LowRECost_30/FRCCc.csv
csv
resource
- 133B9782
+ 553FD69D
cambium/LRMER_LowRECost_30/MROEc.csv
csv
resource
- FB0B66ED
+ 32C42C66
cambium/LRMER_LowRECost_30/MROWc.csv
csv
resource
- 26D91ED7
+ 226BA299
cambium/LRMER_LowRECost_30/NEWEc.csv
csv
resource
- 0C9D4B71
+ 479485BA
cambium/LRMER_LowRECost_30/NWPPc.csv
csv
resource
- 36D5AB21
+ 545BB2E3
cambium/LRMER_LowRECost_30/NYSTc.csv
csv
resource
- D4D57E9E
+ 974DC73F
cambium/LRMER_LowRECost_30/RFCEc.csv
csv
resource
- 5E3DBB97
+ F96686A7
cambium/LRMER_LowRECost_30/RFCMc.csv
csv
resource
- 50C6F71F
+ CC19A1AB
cambium/LRMER_LowRECost_30/RFCWc.csv
csv
resource
- 60116AA9
+ CE3DEA82
cambium/LRMER_LowRECost_30/RMPAc.csv
csv
resource
- A1616B43
+ 2DE79B4A
cambium/LRMER_LowRECost_30/SPNOc.csv
csv
resource
- 29D81AB8
+ B401B0B4
cambium/LRMER_LowRECost_30/SPSOc.csv
csv
resource
- 36C73584
+ 60B0F3AC
cambium/LRMER_LowRECost_30/SRMVc.csv
csv
resource
- FC7052FA
+ 0D0641FF
cambium/LRMER_LowRECost_30/SRMWc.csv
csv
resource
- 89AC0C1F
+ D2B34B11
cambium/LRMER_LowRECost_30/SRSOc.csv
csv
resource
- 31297797
+ 97DBE806
cambium/LRMER_LowRECost_30/SRTVc.csv
csv
resource
- 31B3D171
+ B038F8EC
cambium/LRMER_LowRECost_30/SRVCc.csv
csv
resource
- 25C947AF
+ 2E7B89C3
cambium/LRMER_MidCase_15/AZNMc.csv
csv
resource
- 9C63EAAB
+ 28B76CCC
cambium/LRMER_MidCase_15/CAMXc.csv
csv
resource
- 95CEA9F0
+ A0ECAD3A
cambium/LRMER_MidCase_15/ERCTc.csv
csv
resource
- 9887FA89
+ BD310065
cambium/LRMER_MidCase_15/FRCCc.csv
csv
resource
- CAEB68BE
+ C63EF3D9
cambium/LRMER_MidCase_15/MROEc.csv
csv
resource
- 2FA01F94
+ 9903D7C7
cambium/LRMER_MidCase_15/MROWc.csv
csv
resource
- 2FFE3B56
+ C219F661
cambium/LRMER_MidCase_15/NEWEc.csv
csv
resource
- 1E4B056A
+ A7FC6B11
cambium/LRMER_MidCase_15/NWPPc.csv
csv
resource
- 7FC7859A
+ 286C8D5C
cambium/LRMER_MidCase_15/NYSTc.csv
csv
resource
- 46AFEA2A
+ 79633AAB
cambium/LRMER_MidCase_15/RFCEc.csv
csv
resource
- 49C181DF
+ CF7ACC29
cambium/LRMER_MidCase_15/RFCMc.csv
csv
resource
- AD5DF429
+ 70A07833
cambium/LRMER_MidCase_15/RFCWc.csv
csv
resource
- 3B24E186
+ EA83A970
cambium/LRMER_MidCase_15/RMPAc.csv
csv
resource
- 0941C9D5
+ 0B5C1A80
cambium/LRMER_MidCase_15/SPNOc.csv
csv
resource
- 8EFF0FBD
+ 7C4E8377
cambium/LRMER_MidCase_15/SPSOc.csv
csv
resource
- 0556DFA6
+ 73355534
cambium/LRMER_MidCase_15/SRMVc.csv
csv
resource
- 800F3E34
+ 72E62872
cambium/LRMER_MidCase_15/SRMWc.csv
csv
resource
- 79783179
+ FA0E7317
cambium/LRMER_MidCase_15/SRSOc.csv
csv
resource
- 4F279001
+ 25FD88DB
cambium/LRMER_MidCase_15/SRTVc.csv
csv
resource
- 5199D1A6
+ 0FFBA0E5
cambium/LRMER_MidCase_15/SRVCc.csv
csv
resource
- 544FFCAE
+ D6158FF9
cambium/LRMER_MidCase_15_2025start/AZNMc.csv
@@ -2895,121 +2895,121 @@
cambium/LRMER_MidCase_30/AZNMc.csv
csv
resource
- 0E69BD34
+ 3DB87CF1
cambium/LRMER_MidCase_30/CAMXc.csv
csv
resource
- C229BA24
+ 161ABD7A
cambium/LRMER_MidCase_30/ERCTc.csv
csv
resource
- E96D421F
+ 88555772
cambium/LRMER_MidCase_30/FRCCc.csv
csv
resource
- B11A6E42
+ B056C029
cambium/LRMER_MidCase_30/MROEc.csv
csv
resource
- 792E974D
+ E187AE44
cambium/LRMER_MidCase_30/MROWc.csv
csv
resource
- 26EC7957
+ 620EADCF
cambium/LRMER_MidCase_30/NEWEc.csv
csv
resource
- 43F71E55
+ 2ACE1C08
cambium/LRMER_MidCase_30/NWPPc.csv
csv
resource
- 7CEC396A
+ 39EF25DE
cambium/LRMER_MidCase_30/NYSTc.csv
csv
resource
- A10FA6B9
+ 7B0EE9CE
cambium/LRMER_MidCase_30/RFCEc.csv
csv
resource
- 2D406EC1
+ EBE4BB42
cambium/LRMER_MidCase_30/RFCMc.csv
csv
resource
- AC731567
+ 493FD08A
cambium/LRMER_MidCase_30/RFCWc.csv
csv
resource
- 24AB8F3D
+ E4A80378
cambium/LRMER_MidCase_30/RMPAc.csv
csv
resource
- 63D4EAE1
+ 8703AA02
cambium/LRMER_MidCase_30/SPNOc.csv
csv
resource
- 5F1C0DDF
+ EE37DF78
cambium/LRMER_MidCase_30/SPSOc.csv
csv
resource
- 73EC2CF9
+ 2C7A851D
cambium/LRMER_MidCase_30/SRMVc.csv
csv
resource
- F8E6BFE4
+ A6CF7857
cambium/LRMER_MidCase_30/SRMWc.csv
csv
resource
- EE241C67
+ 8633DFC3
cambium/LRMER_MidCase_30/SRSOc.csv
csv
resource
- 0006443C
+ 25EF7FD1
cambium/LRMER_MidCase_30/SRTVc.csv
csv
resource
- B09A3BCA
+ 966484CB
cambium/LRMER_MidCase_30/SRVCc.csv
csv
resource
- B3BF5C67
+ A6FB5BEB
cambium/README.md
@@ -3039,7 +3039,7 @@
EmissionsReporting_Test.rb
rb
test
- 9DAF1B30
+ F8D3563F
FortCollins2016.epw
@@ -3053,5 +3053,11 @@
test
122E4E19
+
+ smalloffice.osm
+ osm
+ test
+ 40A4F1D3
+
diff --git a/measures/emissions_reporting/tests/EmissionsReporting_Test.rb b/measures/emissions_reporting/tests/EmissionsReporting_Test.rb
index 164bd551f..c19349119 100644
--- a/measures/emissions_reporting/tests/EmissionsReporting_Test.rb
+++ b/measures/emissions_reporting/tests/EmissionsReporting_Test.rb
@@ -42,6 +42,7 @@
require 'fileutils'
require 'openstudio-standards'
require_relative '../../../test/helpers/minitest_helper'
+require 'csv'
class EmissionsReporting_Test < Minitest::Test
def test_number_of_arguments_and_argument_names
@@ -84,54 +85,101 @@ def report_path(test_name)
return "#{run_dir(test_name)}/reports/eplustbl.html"
end
- def print_column_definitions(result_h)
- # print output names for column definitions
- regex = /annual_(.*)_(electricity|natural_gas|fuel_oil|propane)_ghg_emissions_?(.*)_kg/
+ def print_step_values(result_h)
+ CSV.open(File.join(run_dir('test_all_scenarios'),'step_vals.csv'), "w") do |csv|
+ result_h["step_values"].each do |h|
+ csv << [h["name"]]
+ end
+ end
+ end
+
+ # process output names and field descriptions for comstock_column_definitions.csv
+ def print_column_definitions(result_h, test_name)
+ regex = /annual_?(.*)_(electricity|natural_gas|fuel_oil|propane)_ghg_emissions_?(.*)_kg/
result = ""
result_h['step_values'].each do |h|
result_string = "\nresults.csv,emissions_reporting."
value_name = h["name"]
+ # make new col name
result_string << "#{value_name},out.emissions"
- # puts value_name
captures = value_name.scan(regex).flatten
next if captures.empty?
- # puts captures
- captures.each_with_index do |c,i|
- if i == 2 && !c.empty?
- if c.match?(/aer_/)
- result_string << ".#{c}_from_2023"
- elsif c.match?(/lrmer_/)
- if c.match?(/_start_/)
- result_string << ".#{c}"
- else
- result_string << ".#{c}_2023_start"
- end
- else result_string << ".#{c}"
- end
+ # fuel type
+ fuel_type = captures[1]
+ result_string << ".#{fuel_type}" unless fuel_type.empty?
+ # end use
+ end_use = captures[0]
+ if end_use.include?('hvac')
+ result_string << ".enduse_group.hvac"
+ else
+ result_string << ".#{end_use}" unless end_use.empty?
+ end
+ # scenario
+ scenario = captures[2]
+
+ case
+ when scenario.include?('egrid')
+ result_string << ".#{scenario}"
+ field_desc_string = "#{scenario.gsub('_',' ').gsub('egrid','eGRID')} emissions intensity values"
+ when scenario.include?('aer')
+ result_string << ".#{scenario}_from_2023"
+ field_desc_string = "Cambium 2022 #{scenario.gsub('_',' ').gsub('aer', 'Average Emissions Rate').gsub('re','renewable energy').gsub('95','95%')} non-levelized emissions intensity values from 2023"
+ when scenario.include?('lrmer')
+ field_desc_string = "Cambium 2022 #{scenario.gsub('_',' ').gsub('lrmer', 'Long-Range Marginal Emissions Rate').gsub('re','renewable energy').gsub('95','95%').gsub(/\s\d{2}$/,'').gsub(/\s\d{2}\s\d{4}\sstart/,'')} emissions intensity values "
+ if scenario.match?(/_\d{2}_\d{4}_/)
+ result_string << ".#{scenario}"
+ matches = scenario.scan(/_(\d{2})_(\d{4})_start/).flatten
+ field_desc_string << "levelized over #{matches[0]} years starting in #{matches[1]}"
else
- result_string << ".#{c}" unless c.empty?
+ result_string << ".#{scenario}_2023_start"
+ matches = scenario.scan(/_\w{4}_(\d{2})/).flatten
+ field_desc_string << "levelized over #{matches[0]} years starting in 2023"
end
+ end
+ # full_metadata, basic_metadata, data_type, original_units, new_units
+ result_string << ",TRUE,FALSE,float,co2e_kg,co2e_kg"
+
+ # if end_use.empty?
+ # # include total emissions in basic metadata
+ # result_string << ",TRUE,TRUE,float,co2e_kg,co2e_kg"
+ # else
+ # # only include end-use emissions in full metadata
+ # result_string << ",TRUE,FALSE,float,co2e_kg,co2e_kg"
+ # end
+
+ # process fuel string
+ if end_use.empty?
+ fuel_str = "total on-site #{fuel_type.gsub("_"," ")}"
+ else
+ fuel_str = "#{fuel_type.gsub("_"," ")}"
end
- result_string << ",TRUE,TRUE,float,co2e_kg,co2e_kg"
- case
- when captures[2].include?('egrid')
- result_string << ",\"annual greehouse gas emissions from #{captures[0].gsub("_"," ")} #{captures[1].gsub("_"," ")} use, using #{captures[2].gsub("_"," ")} emissions intensity\""
- when captures[2].include?('aer')
- result_string << ",\"annual greehouse gas emissions from #{captures[0].gsub("_"," ")} #{captures[1].gsub("_"," ")} use, using Cambium 2022 #{captures[2]} non-levelized values from 2023\""
- when captures[2].include?('lrmer')
- if captures[2].match?(/_\d{2}_\d{4}_/)
- matches = captures[2].scan(/_(\d{2})_(\d{4})_start/).flatten
- result_string << ",\"annual greehouse gas emissions from #{captures[0].gsub("_"," ")} #{captures[1].gsub("_"," ")} use, using Cambium 2022 #{captures[2]} levelized over #{matches[0]} years starting in #{matches[1]}\""
- else
- matches = captures[2].scan(/_\w{4}_(\d{2})/).flatten
- result_string << ",\"annual greehouse gas emissions from #{captures[0].gsub("_"," ")} #{captures[1].gsub("_"," ")} use, using Cambium 2022 #{captures[2]} levelized over #{matches[0]} years starting in 2023\""
- end
- else result_string << ",\"annual greenhouse gas emissions from on site #{captures[0].gsub("_"," ")} #{captures[1].gsub("_"," ")} use\""
+
+ # end-use string
+ end_use_str = "on-site #{end_use.gsub('_',' ')}"
+
+ # construct field_description
+ if end_use.empty? && scenario.empty?
+ # total non-electric fuel
+ result_string << ",annual greenhouse gas emissions from #{fuel_str} use"
+ elsif end_use.empty?
+ # total electricity with case
+ result_string << ",annual greenhouse gas emissions from #{fuel_str} use using #{field_desc_string}"
+ elsif scenario.empty?
+ # non-elec fuel with end-use
+ result_string << ",annual greenhouse gas emissions from #{end_use_str} #{fuel_str} use"
+ else
+ # electricty end-use with case
+ result_string << ",annual greenhouse gas emissions from #{end_use_str} #{fuel_str} use with #{field_desc_string}"
end
result << result_string
end
- puts result
+
+ CSV.open(File.join(run_dir(test_name),'emissions_columns.csv'), "w") do |csv|
+ result.split("\n").each do |row|
+ csv << row.split(',')
+ end
+ end
end
def run_test(test_name, osm_path, epw_path, argument_map)
@@ -240,7 +288,7 @@ def test_all_scenarios
test_name = 'test_all_scenarios'
puts "\n######\nTEST:#{test_name}\n######\n"
- osm_path = File.dirname(__FILE__) + '/office.osm'
+ osm_path = File.dirname(__FILE__) + '/smalloffice.osm'
epw_path = File.dirname(__FILE__) + '/FortCollins2016.epw'
# create an instance of the measure
@@ -264,16 +312,22 @@ def test_all_scenarios
require 'json'
result_h = JSON.parse(result.to_s)
# test that runperiod totals same as summed hourly
- assert_in_delta(8612.0512, result_h['step_values'].select{|v| v["name"] == "annual_natural_gas_ghg_emissions_kg"}.first["value"], 0.001)
+ assert_in_delta(3384.63, result_h['step_values'].select{|v| v["name"] == "annual_natural_gas_ghg_emissions_kg"}.first["value"], 0.1)
+
+ # test that all electricity emissions are > 0
+ result_h['step_values'].select{ |v| v["name"].include?('cooling_electricity')}.each do |result|
+ assert(result['value'] > 0, "Result for #{result['name']} is zero")
+ end
- # print_column_definitions(result_h)
+ print_step_values(result_h)
+ print_column_definitions(result_h, test_name)
end
def test_hawaii
test_name = 'test_hawaii'
puts "\n######\nTEST:#{test_name}\n######\n"
- osm_path = File.dirname(__FILE__) + '/office.osm'
+ osm_path = File.dirname(__FILE__) + '/smalloffice.osm'
epw_path = File.dirname(__FILE__) + '/FortCollins2016.epw'
# create an instance of the measure
diff --git a/measures/emissions_reporting/tests/smalloffice.osm b/measures/emissions_reporting/tests/smalloffice.osm
new file mode 100644
index 000000000..5d1f64109
--- /dev/null
+++ b/measures/emissions_reporting/tests/smalloffice.osm
@@ -0,0 +1,4925 @@
+
+OS:Version,
+ {9a5199db-a61c-4d92-8100-dba841b7b566}, !- Handle
+ 3.8.0; !- Version Identifier
+
+OS:Building,
+ {3356aedb-116e-430d-91d1-31f2b67492b4}, !- Handle
+ ComStock DOE Ref Pre-1980|SmallOffice, !- Name
+ , !- Building Sector Type
+ , !- North Axis {deg}
+ , !- Nominal Floor to Floor Height {m}
+ , !- Space Type Name
+ {2d4d64c5-7784-4fda-a5f5-513459437905}, !- Default Construction Set Name
+ , !- Default Schedule Set Name
+ , !- Standards Number of Stories
+ , !- Standards Number of Above Ground Stories
+ , !- Standards Template
+ Office; !- Standards Building Type
+
+OS:SpaceType,
+ {0649d243-6d8b-467e-a0fd-8c349fd62e8f}, !- Handle
+ Office WholeBuilding - Sm Office - ComStock DOE Ref Pre-1980, !- Name
+ , !- Default Construction Set Name
+ {04cef2ce-93d5-4f35-a407-25029d875bbe}, !- Default Schedule Set Name
+ {58ca08ce-fa42-4ef8-934b-114f63a4752d}, !- Group Rendering Name
+ {8823fe36-8c2e-4760-a72f-6b1ccabb5a51}, !- Design Specification Outdoor Air Object Name
+ , !- Standards Template
+ Office, !- Standards Building Type
+ WholeBuilding - Sm Office; !- Standards Space Type
+
+OS:Rendering:Color,
+ {58ca08ce-fa42-4ef8-934b-114f63a4752d}, !- Handle
+ Office WholeBuilding - Sm Office, !- Name
+ 120, !- Rendering Red Value
+ 230, !- Rendering Green Value
+ 199; !- Rendering Blue Value
+
+OS:Site,
+ {a189e5d4-347a-41b8-943f-a958c9e61180}, !- Handle
+ Fort Collins Awos_CO_USA, !- Name
+ 40.45, !- Latitude {deg}
+ -105.02, !- Longitude {deg}
+ -7, !- Time Zone {hr}
+ 1529, !- Elevation {m}
+ City; !- Terrain
+
+OS:BuildingStory,
+ {efc86152-8a53-43e5-9739-ead9bf8b462e}, !- Handle
+ Story ground, !- Name
+ 0, !- Nominal Z Coordinate {m}
+ 3.048, !- Nominal Floor to Floor Height {m}
+ , !- Default Construction Set Name
+ , !- Default Schedule Set Name
+ ; !- Group Rendering Name
+
+OS:Space,
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground, !- Name
+ {0649d243-6d8b-467e-a0fd-8c349fd62e8f}, !- Space Type Name
+ , !- Default Construction Set Name
+ , !- Default Schedule Set Name
+ -0, !- Direction of Relative North {deg}
+ -15.6163529673224, !- X Origin {m}
+ -5.20545098910748, !- Y Origin {m}
+ 0, !- Z Origin {m}
+ {efc86152-8a53-43e5-9739-ead9bf8b462e}, !- Building Story Name
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}; !- Thermal Zone Name
+
+OS:Surface,
+ {e1a537e0-6058-4d72-9a95-8fbe84a0c297}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Floor 1, !- Name
+ Floor, !- Surface Type
+ {13e6c855-3a65-406b-b8da-78b7bc6759d6}, !- Construction Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space Name
+ GroundFCfactorMethod, !- Outside Boundary Condition
+ , !- Outside Boundary Condition Object
+ NoSun, !- Sun Exposure
+ NoWind, !- Wind Exposure
+ , !- View Factor to Ground
+ , !- Number of Vertices
+ 2.8421709430404e-14, -4.44089209850063e-15, 0, !- X,Y,Z Vertex 1 {m}
+ 2.8421709430404e-14, 10.410901978215, 0, !- X,Y,Z Vertex 2 {m}
+ 31.2327059346448, 10.410901978215, 0, !- X,Y,Z Vertex 3 {m}
+ 31.2327059346448, -4.44089209850063e-15, 0; !- X,Y,Z Vertex 4 {m}
+
+OS:Surface,
+ {cca80208-22b4-4dba-84d3-14df0ca3dbdf}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 3, !- Name
+ Wall, !- Surface Type
+ , !- Construction Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space Name
+ Outdoors, !- Outside Boundary Condition
+ , !- Outside Boundary Condition Object
+ SunExposed, !- Sun Exposure
+ WindExposed, !- Wind Exposure
+ , !- View Factor to Ground
+ , !- Number of Vertices
+ 2.8421709430404e-14, -4.44089209850063e-15, 3.048, !- X,Y,Z Vertex 1 {m}
+ 2.8421709430404e-14, 10.410901978215, 3.048, !- X,Y,Z Vertex 2 {m}
+ 2.8421709430404e-14, 10.410901978215, 0, !- X,Y,Z Vertex 3 {m}
+ 2.8421709430404e-14, -4.44089209850063e-15, 0; !- X,Y,Z Vertex 4 {m}
+
+OS:Surface,
+ {1c76372e-4150-4625-b978-e7dd269b531a}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 2, !- Name
+ Wall, !- Surface Type
+ , !- Construction Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space Name
+ Outdoors, !- Outside Boundary Condition
+ , !- Outside Boundary Condition Object
+ SunExposed, !- Sun Exposure
+ WindExposed, !- Wind Exposure
+ , !- View Factor to Ground
+ , !- Number of Vertices
+ 2.8421709430404e-14, 10.410901978215, 3.048, !- X,Y,Z Vertex 1 {m}
+ 31.2327059346448, 10.410901978215, 3.048, !- X,Y,Z Vertex 2 {m}
+ 31.2327059346448, 10.410901978215, 0, !- X,Y,Z Vertex 3 {m}
+ 2.8421709430404e-14, 10.410901978215, 0; !- X,Y,Z Vertex 4 {m}
+
+OS:Surface,
+ {9b136912-225c-47fc-90e1-2e955d5f7d0c}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 4, !- Name
+ Wall, !- Surface Type
+ , !- Construction Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space Name
+ Outdoors, !- Outside Boundary Condition
+ , !- Outside Boundary Condition Object
+ SunExposed, !- Sun Exposure
+ WindExposed, !- Wind Exposure
+ , !- View Factor to Ground
+ , !- Number of Vertices
+ 31.2327059346448, 10.410901978215, 3.048, !- X,Y,Z Vertex 1 {m}
+ 31.2327059346448, -4.44089209850063e-15, 3.048, !- X,Y,Z Vertex 2 {m}
+ 31.2327059346448, -4.44089209850063e-15, 0, !- X,Y,Z Vertex 3 {m}
+ 31.2327059346448, 10.410901978215, 0; !- X,Y,Z Vertex 4 {m}
+
+OS:Surface,
+ {67be5c7d-5a9f-4617-a0bc-9c5d856cd818}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 1, !- Name
+ Wall, !- Surface Type
+ , !- Construction Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space Name
+ Outdoors, !- Outside Boundary Condition
+ , !- Outside Boundary Condition Object
+ SunExposed, !- Sun Exposure
+ WindExposed, !- Wind Exposure
+ , !- View Factor to Ground
+ , !- Number of Vertices
+ 31.2327059346448, -4.44089209850063e-15, 3.048, !- X,Y,Z Vertex 1 {m}
+ 2.8421709430404e-14, -4.44089209850063e-15, 3.048, !- X,Y,Z Vertex 2 {m}
+ 2.8421709430404e-14, -4.44089209850063e-15, 0, !- X,Y,Z Vertex 3 {m}
+ 31.2327059346448, -4.44089209850063e-15, 0; !- X,Y,Z Vertex 4 {m}
+
+OS:Surface,
+ {16adadb7-9018-441e-a349-0261c6b2a9f6}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground RoofCeiling 1, !- Name
+ RoofCeiling, !- Surface Type
+ , !- Construction Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space Name
+ Outdoors, !- Outside Boundary Condition
+ , !- Outside Boundary Condition Object
+ SunExposed, !- Sun Exposure
+ WindExposed, !- Wind Exposure
+ , !- View Factor to Ground
+ , !- Number of Vertices
+ 31.2327059346448, -4.44089209850063e-15, 3.048, !- X,Y,Z Vertex 1 {m}
+ 31.2327059346448, 10.410901978215, 3.048, !- X,Y,Z Vertex 2 {m}
+ 2.8421709430404e-14, 10.410901978215, 3.048, !- X,Y,Z Vertex 3 {m}
+ 2.8421709430404e-14, -4.44089209850063e-15, 3.048; !- X,Y,Z Vertex 4 {m}
+
+OS:ThermalZone,
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground, !- Name
+ 1, !- Multiplier
+ , !- Ceiling Height {m}
+ , !- Volume {m3}
+ , !- Floor Area {m2}
+ , !- Zone Inside Convection Algorithm
+ , !- Zone Outside Convection Algorithm
+ , !- Zone Conditioning Equipment List Name
+ {18712918-a872-478d-8031-a535d2036264}, !- Zone Air Inlet Port List
+ {ff8e8c73-8731-4577-ac55-9c4646d7dd20}, !- Zone Air Exhaust Port List
+ {9637294e-84e9-4238-b504-a11717646b06}, !- Zone Air Node Name
+ {f106ff60-dc30-4089-aa91-bca99a72d7c4}, !- Zone Return Air Port List
+ , !- Primary Daylighting Control Name
+ , !- Fraction of Zone Controlled by Primary Daylighting Control
+ , !- Secondary Daylighting Control Name
+ , !- Fraction of Zone Controlled by Secondary Daylighting Control
+ , !- Illuminance Map Name
+ , !- Group Rendering Name
+ {d160b6d2-2526-4711-b52a-ef4f667798ae}, !- Thermostat Name
+ No; !- Use Ideal Air Loads
+
+OS:Node,
+ {d86041a0-2701-49a9-975c-2eef8e766197}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground Zone Air Node, !- Name
+ {9637294e-84e9-4238-b504-a11717646b06}, !- Inlet Port
+ ; !- Outlet Port
+
+OS:Connection,
+ {9637294e-84e9-4238-b504-a11717646b06}, !- Handle
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- Source Object
+ 11, !- Outlet Port
+ {d86041a0-2701-49a9-975c-2eef8e766197}, !- Target Object
+ 2; !- Inlet Port
+
+OS:PortList,
+ {18712918-a872-478d-8031-a535d2036264}, !- Handle
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- HVAC Component
+ {bac6ab62-445d-4d74-bb36-efde746e7354}; !- Port 1
+
+OS:PortList,
+ {ff8e8c73-8731-4577-ac55-9c4646d7dd20}, !- Handle
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}; !- HVAC Component
+
+OS:PortList,
+ {f106ff60-dc30-4089-aa91-bca99a72d7c4}, !- Handle
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- HVAC Component
+ {61c23f50-5a9d-4fdf-8104-66aad6726319}; !- Port 1
+
+OS:Sizing:Zone,
+ {ef6382ea-49a1-4d33-9125-69f8e1068737}, !- Handle
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- Zone or ZoneList Name
+ SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method
+ 12.7777777777778, !- Zone Cooling Design Supply Air Temperature {C}
+ 11.11, !- Zone Cooling Design Supply Air Temperature Difference {deltaC}
+ SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method
+ 50.0000000000001, !- Zone Heating Design Supply Air Temperature {C}
+ 11.11, !- Zone Heating Design Supply Air Temperature Difference {deltaC}
+ 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kg-H2O/kg-air}
+ 0.008, !- Zone Heating Design Supply Air Humidity Ratio {kg-H2O/kg-air}
+ , !- Zone Heating Sizing Factor
+ , !- Zone Cooling Sizing Factor
+ DesignDay, !- Cooling Design Air Flow Method
+ , !- Cooling Design Air Flow Rate {m3/s}
+ , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2}
+ , !- Cooling Minimum Air Flow {m3/s}
+ , !- Cooling Minimum Air Flow Fraction
+ DesignDay, !- Heating Design Air Flow Method
+ , !- Heating Design Air Flow Rate {m3/s}
+ , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2}
+ , !- Heating Maximum Air Flow {m3/s}
+ , !- Heating Maximum Air Flow Fraction
+ No, !- Account for Dedicated Outdoor Air System
+ NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy
+ autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C}
+ autosize, !- Dedicated Outdoor Air High Setpoint Temperature for Design {C}
+ Sensible Load Only No Latent Load, !- Zone Load Sizing Method
+ HumidityRatioDifference, !- Zone Latent Cooling Design Supply Air Humidity Ratio Input Method
+ , !- Zone Dehumidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
+ 0.005, !- Zone Cooling Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
+ HumidityRatioDifference, !- Zone Latent Heating Design Supply Air Humidity Ratio Input Method
+ , !- Zone Humidification Design Supply Air Humidity Ratio {kgWater/kgDryAir}
+ 0.005; !- Zone Humidification Design Supply Air Humidity Ratio Difference {kgWater/kgDryAir}
+
+OS:ZoneHVAC:EquipmentList,
+ {d4d86657-5209-488a-bf0f-cc2abf4dd2cf}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground Zone HVAC Equipment List, !- Name
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- Thermal Zone
+ , !- Load Distribution Scheme
+ {b6083448-e7f2-43a3-8f8e-63a4ef78dff8}, !- Zone Equipment 1
+ 1, !- Zone Equipment Cooling Sequence 1
+ 1, !- Zone Equipment Heating or No-Load Sequence 1
+ , !- Zone Equipment Sequential Cooling Fraction Schedule Name 1
+ ; !- Zone Equipment Sequential Heating Fraction Schedule Name 1
+
+OS:SubSurface,
+ {069d4eab-c1ec-49f0-9df6-4fc4a560b835}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 1 FixedWindow 1, !- Name
+ FixedWindow, !- Sub Surface Type
+ , !- Construction Name
+ {67be5c7d-5a9f-4617-a0bc-9c5d856cd818}, !- Surface Name
+ , !- Outside Boundary Condition Object
+ , !- View Factor to Ground
+ , !- Frame and Divider Name
+ , !- Multiplier
+ , !- Number of Vertices
+ 0.0254000000000284, -4.44089209850063e-15, 1.92212694661973, !- X,Y,Z Vertex 1 {m}
+ 0.0254000000000284, -4.44089209850063e-15, 0.762, !- X,Y,Z Vertex 2 {m}
+ 31.2073059346448, -4.44089209850063e-15, 0.762, !- X,Y,Z Vertex 3 {m}
+ 31.2073059346448, -4.44089209850063e-15, 1.92212694661973; !- X,Y,Z Vertex 4 {m}
+
+OS:SubSurface,
+ {3a5584fd-aa0b-4c1f-a254-33af828b0a55}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 2 FixedWindow 1, !- Name
+ FixedWindow, !- Sub Surface Type
+ , !- Construction Name
+ {1c76372e-4150-4625-b978-e7dd269b531a}, !- Surface Name
+ , !- Outside Boundary Condition Object
+ , !- View Factor to Ground
+ , !- Frame and Divider Name
+ , !- Multiplier
+ , !- Number of Vertices
+ 31.2073059346448, 10.410901978215, 1.92212694661973, !- X,Y,Z Vertex 1 {m}
+ 31.2073059346448, 10.410901978215, 0.762, !- X,Y,Z Vertex 2 {m}
+ 0.0254000000000261, 10.410901978215, 0.762, !- X,Y,Z Vertex 3 {m}
+ 0.0254000000000261, 10.410901978215, 1.92212694661973; !- X,Y,Z Vertex 4 {m}
+
+OS:SubSurface,
+ {418a1cdc-1370-4809-ab91-39ec618605b8}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 3 FixedWindow 1, !- Name
+ FixedWindow, !- Sub Surface Type
+ , !- Construction Name
+ {cca80208-22b4-4dba-84d3-14df0ca3dbdf}, !- Surface Name
+ , !- Outside Boundary Condition Object
+ , !- View Factor to Ground
+ , !- Frame and Divider Name
+ , !- Multiplier
+ , !- Number of Vertices
+ 2.8421709430404e-14, 10.385501978215, 1.92591934486781, !- X,Y,Z Vertex 1 {m}
+ 2.8421709430404e-14, 10.385501978215, 0.762, !- X,Y,Z Vertex 2 {m}
+ 2.8421709430404e-14, 0.0253999999999959, 0.762, !- X,Y,Z Vertex 3 {m}
+ 2.8421709430404e-14, 0.0253999999999959, 1.92591934486781; !- X,Y,Z Vertex 4 {m}
+
+OS:SubSurface,
+ {9c854134-e62f-4eb7-917b-6cdc0e5be696}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Wall 4 FixedWindow 1, !- Name
+ FixedWindow, !- Sub Surface Type
+ , !- Construction Name
+ {9b136912-225c-47fc-90e1-2e955d5f7d0c}, !- Surface Name
+ , !- Outside Boundary Condition Object
+ , !- View Factor to Ground
+ , !- Frame and Divider Name
+ , !- Multiplier
+ , !- Number of Vertices
+ 31.2327059346448, 0.0253999999999956, 1.92591934486781, !- X,Y,Z Vertex 1 {m}
+ 31.2327059346448, 0.0253999999999956, 0.762, !- X,Y,Z Vertex 2 {m}
+ 31.2327059346448, 10.385501978215, 0.762, !- X,Y,Z Vertex 3 {m}
+ 31.2327059346448, 10.385501978215, 1.92591934486781; !- X,Y,Z Vertex 4 {m}
+
+OS:RunPeriodControl:DaylightSavingTime,
+ {34b28b14-7c9a-4f5f-ba46-8cb39b27f5bd}, !- Handle
+ 2nd Sunday in March, !- Start Date
+ 1st Sunday in November; !- End Date
+
+OS:YearDescription,
+ {5439e983-a1d5-4b57-8a6b-0e4786b7cdf7}, !- Handle
+ 2018, !- Calendar Year
+ , !- Day of Week for Start Day
+ ; !- Is Leap Year
+
+OS:Timestep,
+ {f5e6da30-9a58-4f2b-9ece-1a63b54179db}, !- Handle
+ 4; !- Number of Timesteps per Hour
+
+OS:RunPeriod,
+ {ce4628ae-378c-4610-9e4e-0bbc93026170}, !- Handle
+ Run Period 1, !- Name
+ 1, !- Begin Month
+ 1, !- Begin Day of Month
+ 12, !- End Month
+ 31, !- End Day of Month
+ , !- Use Weather File Holidays and Special Days
+ , !- Use Weather File Daylight Saving Period
+ , !- Apply Weekend Holiday Rule
+ , !- Use Weather File Rain Indicators
+ , !- Use Weather File Snow Indicators
+ ; !- Number of Times Runperiod to be Repeated
+
+OS:WeatherFile,
+ {09b3998a-a70b-42f5-a04a-ed9e59628409}, !- Handle
+ Fort Collins Awos, !- City
+ CO, !- State Province Region
+ USA, !- Country
+ TMY3, !- Data Source
+ 724769, !- WMO Number
+ 40.45, !- Latitude {deg}
+ -105.02, !- Longitude {deg}
+ -7, !- Time Zone {hr}
+ 1529, !- Elevation {m}
+ files/USA_CO_Fort.Collins.AWOS.724769_TMY3.epw, !- Url
+ C2C10117, !- Checksum
+ , !- Start Date Actual Year
+ Sunday; !- Start Day of Week
+
+OS:SizingPeriod:DesignDay,
+ {5e7005fb-1019-46c1-9baf-ca4b3cec04a0}, !- Handle
+ Fort Collins Awos Ann Clg .4% Condns DB=>MWB, !- Name
+ 34.2, !- Maximum Dry-Bulb Temperature {C}
+ 15.7, !- Daily Dry-Bulb Temperature Range {deltaC}
+ 84255, !- Barometric Pressure {Pa}
+ 4.1, !- Wind Speed {m/s}
+ 150, !- Wind Direction {deg}
+ , !- Sky Clearness
+ No, !- Rain Indicator
+ No, !- Snow Indicator
+ 21, !- Day of Month
+ 7, !- Month
+ SummerDesignDay, !- Day Type
+ No, !- Daylight Saving Time Indicator
+ Wetbulb, !- Humidity Condition Type
+ , !- Humidity Condition Day Schedule Name
+ 15.8, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C}
+ , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir}
+ , !- Enthalpy at Maximum Dry-Bulb {J/kg}
+ DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type
+ , !- Dry-Bulb Temperature Range Modifier Day Schedule Name
+ ASHRAETau, !- Solar Model Indicator
+ , !- Beam Solar Day Schedule Name
+ , !- Diffuse Solar Day Schedule Name
+ 0.431, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance {dimensionless}
+ 2.008; !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance {dimensionless}
+
+OS:SizingPeriod:DesignDay,
+ {ec90e28c-833c-4fe8-ac6c-acc10979493d}, !- Handle
+ Fort Collins Awos Ann Clg .4% Condns WB=>MDB, !- Name
+ 27.9, !- Maximum Dry-Bulb Temperature {C}
+ 15.7, !- Daily Dry-Bulb Temperature Range {deltaC}
+ 84255, !- Barometric Pressure {Pa}
+ 4.1, !- Wind Speed {m/s}
+ 150, !- Wind Direction {deg}
+ , !- Sky Clearness
+ No, !- Rain Indicator
+ No, !- Snow Indicator
+ 21, !- Day of Month
+ 7, !- Month
+ SummerDesignDay, !- Day Type
+ No, !- Daylight Saving Time Indicator
+ Wetbulb, !- Humidity Condition Type
+ , !- Humidity Condition Day Schedule Name
+ 18.2, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C}
+ , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir}
+ , !- Enthalpy at Maximum Dry-Bulb {J/kg}
+ DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type
+ , !- Dry-Bulb Temperature Range Modifier Day Schedule Name
+ ASHRAETau, !- Solar Model Indicator
+ , !- Beam Solar Day Schedule Name
+ , !- Diffuse Solar Day Schedule Name
+ 0.431, !- ASHRAE Clear Sky Optical Depth for Beam Irradiance {dimensionless}
+ 2.008; !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance {dimensionless}
+
+OS:SizingPeriod:DesignDay,
+ {7bd62f8b-1e8e-4c3e-a0e4-1ee4073a9531}, !- Handle
+ Fort Collins Awos Ann Htg 99.6% Condns DB, !- Name
+ -17.7, !- Maximum Dry-Bulb Temperature {C}
+ 0, !- Daily Dry-Bulb Temperature Range {deltaC}
+ 84255, !- Barometric Pressure {Pa}
+ 2.2, !- Wind Speed {m/s}
+ 70, !- Wind Direction {deg}
+ 0, !- Sky Clearness
+ No, !- Rain Indicator
+ No, !- Snow Indicator
+ 21, !- Day of Month
+ 1, !- Month
+ WinterDesignDay, !- Day Type
+ No, !- Daylight Saving Time Indicator
+ Wetbulb, !- Humidity Condition Type
+ , !- Humidity Condition Day Schedule Name
+ -17.7, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C}
+ , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir}
+ , !- Enthalpy at Maximum Dry-Bulb {J/kg}
+ DefaultMultipliers, !- Dry-Bulb Temperature Range Modifier Type
+ , !- Dry-Bulb Temperature Range Modifier Day Schedule Name
+ ASHRAEClearSky; !- Solar Model Indicator
+
+OS:ClimateZones,
+ {2badd941-381e-45a0-88d2-4fa20aaf3d8a}, !- Handle
+ ASHRAE, !- Climate Zone Institution Name 1
+ ANSI/ASHRAE Standard 169, !- Climate Zone Document Name 1
+ 2006, !- Climate Zone Document Year 1
+ 5B, !- Climate Zone Value 1
+ CEC, !- Climate Zone Institution Name 2
+ California Climate Zone Descriptions, !- Climate Zone Document Name 2
+ 1995, !- Climate Zone Document Year 2
+ ; !- Climate Zone Value 2
+
+OS:Site:WaterMainsTemperature,
+ {baaa0a9c-233a-43a2-8b91-ee5e17461ece}, !- Handle
+ Correlation, !- Calculation Method
+ , !- Temperature Schedule Name
+ 8.25833333333333, !- Annual Average Outdoor Air Temperature {C}
+ 27.1; !- Maximum Difference In Monthly Average Outdoor Air Temperatures {deltaC}
+
+OS:Site:GroundTemperature:Shallow,
+ {f1e9d78e-1863-4345-8d69-4b05f6ddeabf}, !- Handle
+ 1.3, !- January Surface Ground Temperature {C}
+ -2.9, !- February Surface Ground Temperature {C}
+ -4, !- March Surface Ground Temperature {C}
+ -3, !- April Surface Ground Temperature {C}
+ 2.6, !- May Surface Ground Temperature {C}
+ 9, !- June Surface Ground Temperature {C}
+ 14.9, !- July Surface Ground Temperature {C}
+ 19.2, !- August Surface Ground Temperature {C}
+ 20.5, !- September Surface Ground Temperature {C}
+ 18.5, !- October Surface Ground Temperature {C}
+ 13.6, !- November Surface Ground Temperature {C}
+ 7.4; !- December Surface Ground Temperature {C}
+
+OS:Site:GroundTemperature:Deep,
+ {f4833143-1918-45ba-b99a-8f1e8b77c690}, !- Handle
+ 7.6, !- January Deep Ground Temperature {C}
+ 4.5, !- February Deep Ground Temperature {C}
+ 2.6, !- March Deep Ground Temperature {C}
+ 2.1, !- April Deep Ground Temperature {C}
+ 3.2, !- May Deep Ground Temperature {C}
+ 5.7, !- June Deep Ground Temperature {C}
+ 8.8, !- July Deep Ground Temperature {C}
+ 11.9, !- August Deep Ground Temperature {C}
+ 14, !- September Deep Ground Temperature {C}
+ 14.5, !- October Deep Ground Temperature {C}
+ 13.3, !- November Deep Ground Temperature {C}
+ 10.8; !- December Deep Ground Temperature {C}
+
+OS:Site:GroundTemperature:FCfactorMethod,
+ {0d2022c6-d544-4f1b-84af-d38de9d8a8d6}, !- Handle
+ 6.3, !- January Ground Temperature {C}
+ 1.1, !- February Ground Temperature {C}
+ -2.5, !- March Ground Temperature {C}
+ -4.5, !- April Ground Temperature {C}
+ -0.4, !- May Ground Temperature {C}
+ 3.6, !- June Ground Temperature {C}
+ 6.6, !- July Ground Temperature {C}
+ 14, !- August Ground Temperature {C}
+ 16.5, !- September Ground Temperature {C}
+ 22.6, !- October Ground Temperature {C}
+ 20.7, !- November Ground Temperature {C}
+ 15.1; !- December Ground Temperature {C}
+
+OS:People:Definition,
+ {f53783f4-54c3-44bf-ad2b-5b94a119f9d3}, !- Handle
+ Office WholeBuilding - Sm Office People Definition, !- Name
+ People/Area, !- Number of People Calculation Method
+ , !- Number of People {people}
+ 0.0538195520835486, !- People per Space Floor Area {person/m2}
+ , !- Space Floor Area per Person {m2/person}
+ 0.3; !- Fraction Radiant
+
+OS:People,
+ {97c484ab-ca79-4de0-b826-147ee700ed97}, !- Handle
+ Office WholeBuilding - Sm Office People, !- Name
+ {f53783f4-54c3-44bf-ad2b-5b94a119f9d3}, !- People Definition Name
+ {0649d243-6d8b-467e-a0fd-8c349fd62e8f}, !- Space or SpaceType Name
+ , !- Number of People Schedule Name
+ , !- Activity Level Schedule Name
+ , !- Surface Name/Angle Factor List Name
+ {c5c42b72-4af8-4ab3-880a-2132543541ec}, !- Work Efficiency Schedule Name
+ {cb4df9dd-a976-4b55-b218-97cb47ab1d86}, !- Clothing Insulation Schedule Name
+ {0dd586d8-2214-4b47-a34c-d60a897d49e8}, !- Air Velocity Schedule Name
+ 1; !- Multiplier
+
+OS:Schedule:Ruleset,
+ {cb4df9dd-a976-4b55-b218-97cb47ab1d86}, !- Handle
+ Clothing Schedule, !- Name
+ {ab868649-08fa-44bc-920d-ee0c8b9af089}, !- Schedule Type Limits Name
+ {4c60e612-af13-4805-bb2f-c031c61304df}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {4c60e612-af13-4805-bb2f-c031c61304df}, !- Handle
+ Clothing Schedule Default Winter Clothes, !- Name
+ {ab868649-08fa-44bc-920d-ee0c8b9af089}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 1; !- Value Until Time 1
+
+OS:Schedule:Rule,
+ {b8390a7f-7ad0-461e-be0c-9850d2ce9fc8}, !- Handle
+ Schedule Rule 1, !- Name
+ {cb4df9dd-a976-4b55-b218-97cb47ab1d86}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {10e143ff-d826-4086-b921-13e0759588f6}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 5, !- Start Month
+ 1, !- Start Day
+ 9, !- End Month
+ 30; !- End Day
+
+OS:Schedule:Day,
+ {10e143ff-d826-4086-b921-13e0759588f6}, !- Handle
+ Clothing Schedule Summer Clothes, !- Name
+ {ab868649-08fa-44bc-920d-ee0c8b9af089}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0.5; !- Value Until Time 1
+
+OS:ScheduleTypeLimits,
+ {ab868649-08fa-44bc-920d-ee0c8b9af089}, !- Handle
+ ClothingInsulation, !- Name
+ 0, !- Lower Limit Value
+ , !- Upper Limit Value
+ Continuous, !- Numeric Type
+ ClothingInsulation; !- Unit Type
+
+OS:Schedule:Ruleset,
+ {0dd586d8-2214-4b47-a34c-d60a897d49e8}, !- Handle
+ Air Velocity Schedule, !- Name
+ {a4001269-bdc7-4ea5-ae9f-acb8262dfb6f}, !- Schedule Type Limits Name
+ {2afd4b94-415b-4a4b-ae32-87bd01b12bda}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {2afd4b94-415b-4a4b-ae32-87bd01b12bda}, !- Handle
+ Air Velocity Schedule Default, !- Name
+ {a4001269-bdc7-4ea5-ae9f-acb8262dfb6f}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0.2; !- Value Until Time 1
+
+OS:ScheduleTypeLimits,
+ {a4001269-bdc7-4ea5-ae9f-acb8262dfb6f}, !- Handle
+ Velocity, !- Name
+ 0, !- Lower Limit Value
+ , !- Upper Limit Value
+ Continuous, !- Numeric Type
+ Velocity; !- Unit Type
+
+OS:Schedule:Ruleset,
+ {c5c42b72-4af8-4ab3-880a-2132543541ec}, !- Handle
+ Work Efficiency Schedule, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {0787c8cc-ca04-4cb1-bda7-4bd63507326c}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {0787c8cc-ca04-4cb1-bda7-4bd63507326c}, !- Handle
+ Work Efficiency Schedule Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0; !- Value Until Time 1
+
+OS:ScheduleTypeLimits,
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Handle
+ Fractional, !- Name
+ 0, !- Lower Limit Value
+ 1, !- Upper Limit Value
+ Continuous; !- Numeric Type
+
+OS:Lights:Definition,
+ {7314a524-234a-44b5-84d6-06b847a87101}, !- Handle
+ Office WholeBuilding - Sm Office Lights Definition, !- Name
+ Watts/Area, !- Design Level Calculation Method
+ , !- Lighting Level {W}
+ 20.4568117469568, !- Watts per Space Floor Area {W/m2}
+ , !- Watts per Person {W/person}
+ 0.655386, !- Fraction Radiant
+ 0.2, !- Fraction Visible
+ 0; !- Return Air Fraction
+
+OS:Lights,
+ {ac8cde9a-ad5b-4a72-b9a8-181be6b5f468}, !- Handle
+ Office WholeBuilding - Sm Office Lights, !- Name
+ {7314a524-234a-44b5-84d6-06b847a87101}, !- Lights Definition Name
+ {0649d243-6d8b-467e-a0fd-8c349fd62e8f}, !- Space or SpaceType Name
+ , !- Schedule Name
+ 1, !- Fraction Replaceable
+ , !- Multiplier
+ General; !- End-Use Subcategory
+
+OS:AdditionalProperties,
+ {1463e925-fe2f-4e56-b75f-33900059d2bc}, !- Handle
+ {7314a524-234a-44b5-84d6-06b847a87101}, !- Object Name
+ lpd_fraction_linear_fluorescent, !- Feature Name 1
+ Double, !- Feature Data Type 1
+ 0.89910000000000001, !- Feature Value 1
+ lpd_fraction_compact_fluorescent, !- Feature Name 2
+ Double, !- Feature Data Type 2
+ 0.071900000000000006, !- Feature Value 2
+ lpd_fraction_high_bay, !- Feature Name 3
+ Double, !- Feature Data Type 3
+ 0, !- Feature Value 3
+ lpd_fraction_specialty_lighting, !- Feature Name 4
+ Double, !- Feature Data Type 4
+ 0.023199999999999998, !- Feature Value 4
+ lpd_fraction_exit_lighting, !- Feature Name 5
+ Double, !- Feature Data Type 5
+ 0.0057999999999999996; !- Feature Value 5
+
+OS:ElectricEquipment:Definition,
+ {6e27419a-f7eb-4356-92f1-510e08c7efb8}, !- Handle
+ Office WholeBuilding - Sm Office Elec Equip Definition, !- Name
+ Watts/Area, !- Design Level Calculation Method
+ , !- Design Level {W}
+ 10.7639104167097, !- Watts per Space Floor Area {W/m2}
+ , !- Watts per Person {W/person}
+ 0, !- Fraction Latent
+ 0.5, !- Fraction Radiant
+ 0; !- Fraction Lost
+
+OS:ElectricEquipment,
+ {54ba9ac5-c953-402e-8a8d-45aa40dafd27}, !- Handle
+ Office WholeBuilding - Sm Office Elec Equip, !- Name
+ {6e27419a-f7eb-4356-92f1-510e08c7efb8}, !- Electric Equipment Definition Name
+ {0649d243-6d8b-467e-a0fd-8c349fd62e8f}, !- Space or SpaceType Name
+ , !- Schedule Name
+ , !- Multiplier
+ General; !- End-Use Subcategory
+
+OS:DesignSpecification:OutdoorAir,
+ {8823fe36-8c2e-4760-a72f-6b1ccabb5a51}, !- Handle
+ Office WholeBuilding - Sm Office Ventilation, !- Name
+ Sum, !- Outdoor Air Method
+ 0.009438948864, !- Outdoor Air Flow per Person {m3/s-person}
+ , !- Outdoor Air Flow per Floor Area {m3/s-m2}
+ , !- Outdoor Air Flow Rate {m3/s}
+ , !- Outdoor Air Flow Air Changes per Hour {1/hr}
+ ; !- Outdoor Air Flow Rate Fraction Schedule Name
+
+OS:DefaultScheduleSet,
+ {04cef2ce-93d5-4f35-a407-25029d875bbe}, !- Handle
+ Office WholeBuilding - Sm Office Schedule Set, !- Name
+ , !- Hours of Operation Schedule Name
+ {cae9866a-da02-418e-9435-45b947fc1f27}, !- Number of People Schedule Name
+ {c2e9da29-94ca-4f43-8b6c-bef26559c419}, !- People Activity Level Schedule Name
+ {871075b9-39b5-4afe-9dd2-115aedca974f}, !- Lighting Schedule Name
+ {f2cb7f1a-8571-497b-be52-e9666898f691}, !- Electric Equipment Schedule Name
+ , !- Gas Equipment Schedule Name
+ , !- Hot Water Equipment Schedule Name
+ {090a79f1-a351-41bf-9f75-25c9635fd1f2}, !- Infiltration Schedule Name
+ , !- Steam Equipment Schedule Name
+ ; !- Other Equipment Schedule Name
+
+OS:Schedule:Ruleset,
+ {cae9866a-da02-418e-9435-45b947fc1f27}, !- Handle
+ Small Office Bldg Occ, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {a6d47835-e7ef-4dff-af3f-359890ec6238}, !- Default Day Schedule Name
+ {90830e88-20fb-492d-8267-a30dd37121fd}, !- Summer Design Day Schedule Name
+ {39e0292d-00ab-4e35-85e5-64e4cf9ac62c}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {a6d47835-e7ef-4dff-af3f-359890ec6238}, !- Handle
+ Small Office Bldg Occ Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 7, !- Hour 2
+ 0, !- Minute 2
+ 0.1, !- Value Until Time 2
+ 8, !- Hour 3
+ 0, !- Minute 3
+ 0.2, !- Value Until Time 3
+ 12, !- Hour 4
+ 0, !- Minute 4
+ 0.95, !- Value Until Time 4
+ 13, !- Hour 5
+ 0, !- Minute 5
+ 0.5, !- Value Until Time 5
+ 17, !- Hour 6
+ 0, !- Minute 6
+ 0.95, !- Value Until Time 6
+ 18, !- Hour 7
+ 0, !- Minute 7
+ 0.3, !- Value Until Time 7
+ 20, !- Hour 8
+ 0, !- Minute 8
+ 0.1, !- Value Until Time 8
+ 24, !- Hour 9
+ 0, !- Minute 9
+ 0.05; !- Value Until Time 9
+
+OS:Schedule:Rule,
+ {27dedce4-fd21-4337-aeeb-6e1d15fb6e4a}, !- Handle
+ Schedule Rule 2, !- Name
+ {cae9866a-da02-418e-9435-45b947fc1f27}, !- Schedule Ruleset Name
+ 1, !- Rule Order
+ {e290a34b-2730-40b8-b8aa-60cb562b5687}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ Yes, !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {e290a34b-2730-40b8-b8aa-60cb562b5687}, !- Handle
+ Small Office Bldg Occ Sat Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 8, !- Hour 2
+ 0, !- Minute 2
+ 0.1, !- Value Until Time 2
+ 12, !- Hour 3
+ 0, !- Minute 3
+ 0.3, !- Value Until Time 3
+ 17, !- Hour 4
+ 0, !- Minute 4
+ 0.1, !- Value Until Time 4
+ 24, !- Hour 5
+ 0, !- Minute 5
+ 0; !- Value Until Time 5
+
+OS:Schedule:Day,
+ {90830e88-20fb-492d-8267-a30dd37121fd}, !- Handle
+ Small Office Bldg Occ Summer Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 22, !- Hour 2
+ 0, !- Minute 2
+ 1, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 0.05; !- Value Until Time 3
+
+OS:Schedule:Day,
+ {39e0292d-00ab-4e35-85e5-64e4cf9ac62c}, !- Handle
+ Small Office Bldg Occ Winter Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0; !- Value Until Time 1
+
+OS:Schedule:Rule,
+ {dae9db86-ec2c-4922-b2ea-32a75a988a00}, !- Handle
+ Schedule Rule 3, !- Name
+ {cae9866a-da02-418e-9435-45b947fc1f27}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {4a5b211b-54d8-42c7-8aa8-853e6887bba6}, !- Day Schedule Name
+ Yes, !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {4a5b211b-54d8-42c7-8aa8-853e6887bba6}, !- Handle
+ Small Office Bldg Occ WntrDsn|Sun Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0; !- Value Until Time 1
+
+OS:Schedule:Ruleset,
+ {c2e9da29-94ca-4f43-8b6c-bef26559c419}, !- Handle
+ Small Office Activity, !- Name
+ {47aea418-c7da-4d0f-91e8-8f446f9a3847}, !- Schedule Type Limits Name
+ {39c3750a-7081-492c-9bb6-618b9b7dd009}, !- Default Day Schedule Name
+ {caf09185-2329-4e63-90c0-16ad27663765}, !- Summer Design Day Schedule Name
+ {52cd4014-85af-4f61-8b45-93bb424fa860}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {39c3750a-7081-492c-9bb6-618b9b7dd009}, !- Handle
+ Small Office Activity Default, !- Name
+ {47aea418-c7da-4d0f-91e8-8f446f9a3847}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 120; !- Value Until Time 1
+
+OS:Schedule:Day,
+ {52cd4014-85af-4f61-8b45-93bb424fa860}, !- Handle
+ Small Office Activity Winter Design Day, !- Name
+ {47aea418-c7da-4d0f-91e8-8f446f9a3847}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 120; !- Value Until Time 1
+
+OS:Schedule:Day,
+ {caf09185-2329-4e63-90c0-16ad27663765}, !- Handle
+ Small Office Activity Summer Design Day, !- Name
+ {47aea418-c7da-4d0f-91e8-8f446f9a3847}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 120; !- Value Until Time 1
+
+OS:ScheduleTypeLimits,
+ {47aea418-c7da-4d0f-91e8-8f446f9a3847}, !- Handle
+ ActivityLevel, !- Name
+ 0, !- Lower Limit Value
+ , !- Upper Limit Value
+ Continuous, !- Numeric Type
+ ActivityLevel; !- Unit Type
+
+OS:Schedule:Ruleset,
+ {871075b9-39b5-4afe-9dd2-115aedca974f}, !- Handle
+ Office BLDG_LIGHT_EndUseData, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {cb040d3a-750c-470b-affd-7e10050777f7}, !- Default Day Schedule Name
+ {bd1f6932-9bab-424b-a7bc-016a6754fd8b}, !- Summer Design Day Schedule Name
+ {e769f520-940a-425b-89cf-2275667edee3}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {cb040d3a-750c-470b-affd-7e10050777f7}, !- Handle
+ Office BLDG_LIGHT_EndUseData Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.049334, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.033997, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.036709, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.050454, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.039273, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.04068, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.085771, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.186752, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.542086, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.773073, !- Value Until Time 10
+ 11, !- Hour 11
+ 0, !- Minute 11
+ 0.843215, !- Value Until Time 11
+ 12, !- Hour 12
+ 0, !- Minute 12
+ 0.85, !- Value Until Time 12
+ 13, !- Hour 13
+ 0, !- Minute 13
+ 0.817939, !- Value Until Time 13
+ 14, !- Hour 14
+ 0, !- Minute 14
+ 0.768039, !- Value Until Time 14
+ 15, !- Hour 15
+ 0, !- Minute 15
+ 0.792188, !- Value Until Time 15
+ 16, !- Hour 16
+ 0, !- Minute 16
+ 0.765202, !- Value Until Time 16
+ 17, !- Hour 17
+ 0, !- Minute 17
+ 0.646746, !- Value Until Time 17
+ 18, !- Hour 18
+ 0, !- Minute 18
+ 0.299884, !- Value Until Time 18
+ 19, !- Hour 19
+ 0, !- Minute 19
+ 0.135379, !- Value Until Time 19
+ 20, !- Hour 20
+ 0, !- Minute 20
+ 0.09143, !- Value Until Time 20
+ 21, !- Hour 21
+ 0, !- Minute 21
+ 0.086298, !- Value Until Time 21
+ 22, !- Hour 22
+ 0, !- Minute 22
+ 0.087357, !- Value Until Time 22
+ 23, !- Hour 23
+ 0, !- Minute 23
+ 0.086798, !- Value Until Time 23
+ 24, !- Hour 24
+ 0, !- Minute 24
+ 0.053949; !- Value Until Time 24
+
+OS:Schedule:Rule,
+ {fb0f73cb-3b35-4df5-8559-ab27f806a783}, !- Handle
+ Schedule Rule 4, !- Name
+ {871075b9-39b5-4afe-9dd2-115aedca974f}, !- Schedule Ruleset Name
+ 2, !- Rule Order
+ {e19f6d13-9844-4f7d-983c-90e5265ffe23}, !- Day Schedule Name
+ , !- Apply Sunday
+ Yes, !- Apply Monday
+ Yes, !- Apply Tuesday
+ Yes, !- Apply Wednesday
+ Yes, !- Apply Thursday
+ Yes, !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {e19f6d13-9844-4f7d-983c-90e5265ffe23}, !- Handle
+ Office BLDG_LIGHT_EndUseData Default|Wkdy Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.049334, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.033997, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.036709, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.050454, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.039273, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.04068, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.085771, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.186752, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.542086, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.773073, !- Value Until Time 10
+ 11, !- Hour 11
+ 0, !- Minute 11
+ 0.843215, !- Value Until Time 11
+ 12, !- Hour 12
+ 0, !- Minute 12
+ 0.85, !- Value Until Time 12
+ 13, !- Hour 13
+ 0, !- Minute 13
+ 0.817939, !- Value Until Time 13
+ 14, !- Hour 14
+ 0, !- Minute 14
+ 0.768039, !- Value Until Time 14
+ 15, !- Hour 15
+ 0, !- Minute 15
+ 0.792188, !- Value Until Time 15
+ 16, !- Hour 16
+ 0, !- Minute 16
+ 0.765202, !- Value Until Time 16
+ 17, !- Hour 17
+ 0, !- Minute 17
+ 0.646746, !- Value Until Time 17
+ 18, !- Hour 18
+ 0, !- Minute 18
+ 0.299884, !- Value Until Time 18
+ 19, !- Hour 19
+ 0, !- Minute 19
+ 0.135379, !- Value Until Time 19
+ 20, !- Hour 20
+ 0, !- Minute 20
+ 0.09143, !- Value Until Time 20
+ 21, !- Hour 21
+ 0, !- Minute 21
+ 0.086298, !- Value Until Time 21
+ 22, !- Hour 22
+ 0, !- Minute 22
+ 0.087357, !- Value Until Time 22
+ 23, !- Hour 23
+ 0, !- Minute 23
+ 0.086798, !- Value Until Time 23
+ 24, !- Hour 24
+ 0, !- Minute 24
+ 0.053949; !- Value Until Time 24
+
+OS:Schedule:Rule,
+ {3409b40f-67ca-416b-8b90-5635badf8ec6}, !- Handle
+ Schedule Rule 5, !- Name
+ {871075b9-39b5-4afe-9dd2-115aedca974f}, !- Schedule Ruleset Name
+ 1, !- Rule Order
+ {a6de7bb1-cf6b-4404-a395-6e27e7d1e97d}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ Yes, !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {a6de7bb1-cf6b-4404-a395-6e27e7d1e97d}, !- Handle
+ Office BLDG_LIGHT_EndUseData Sat Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.044066259, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.044439702, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.041053394, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.043692817, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.041740259, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.042359092, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.050653671, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.045399984, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.052663191, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.06820457, !- Value Until Time 10
+ 13, !- Hour 11
+ 0, !- Minute 11
+ 0.089708448, !- Value Until Time 11
+ 14, !- Hour 12
+ 0, !- Minute 12
+ 0.084480541, !- Value Until Time 12
+ 15, !- Hour 13
+ 0, !- Minute 13
+ 0.0704679, !- Value Until Time 13
+ 16, !- Hour 14
+ 0, !- Minute 14
+ 0.068030468, !- Value Until Time 14
+ 17, !- Hour 15
+ 0, !- Minute 15
+ 0.067899891, !- Value Until Time 15
+ 18, !- Hour 16
+ 0, !- Minute 16
+ 0.063771049, !- Value Until Time 16
+ 19, !- Hour 17
+ 0, !- Minute 17
+ 0.064678999, !- Value Until Time 17
+ 20, !- Hour 18
+ 0, !- Minute 18
+ 0.063855804, !- Value Until Time 18
+ 21, !- Hour 19
+ 0, !- Minute 19
+ 0.063765228, !- Value Until Time 19
+ 22, !- Hour 20
+ 0, !- Minute 20
+ 0.063778708, !- Value Until Time 20
+ 23, !- Hour 21
+ 0, !- Minute 21
+ 0.064738916, !- Value Until Time 21
+ 24, !- Hour 22
+ 0, !- Minute 22
+ 0.053690475; !- Value Until Time 22
+
+OS:Schedule:Day,
+ {bd1f6932-9bab-424b-a7bc-016a6754fd8b}, !- Handle
+ Office BLDG_LIGHT_EndUseData Summer Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 1; !- Value Until Time 1
+
+OS:Schedule:Rule,
+ {e5c7ad94-6035-47a4-83cf-f89fec0e40c7}, !- Handle
+ Schedule Rule 6, !- Name
+ {871075b9-39b5-4afe-9dd2-115aedca974f}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {a049ce06-45eb-45fc-818e-807ca6dfe594}, !- Day Schedule Name
+ Yes, !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {a049ce06-45eb-45fc-818e-807ca6dfe594}, !- Handle
+ Office BLDG_LIGHT_EndUseData Sun Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.044813145, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.043346048, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.043604651, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.043799515, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.041612206, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.042092347, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.043852864, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.044946518, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.042279069, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.04299928, !- Value Until Time 10
+ 11, !- Hour 11
+ 0, !- Minute 11
+ 0.045746752, !- Value Until Time 11
+ 12, !- Hour 12
+ 0, !- Minute 12
+ 0.064026115, !- Value Until Time 12
+ 13, !- Hour 13
+ 0, !- Minute 13
+ 0.063271893, !- Value Until Time 13
+ 14, !- Hour 14
+ 0, !- Minute 14
+ 0.063286181, !- Value Until Time 14
+ 15, !- Hour 15
+ 0, !- Minute 15
+ 0.063938755, !- Value Until Time 15
+ 16, !- Hour 16
+ 0, !- Minute 16
+ 0.06135133, !- Value Until Time 16
+ 17, !- Hour 17
+ 0, !- Minute 17
+ 0.063721436, !- Value Until Time 17
+ 18, !- Hour 18
+ 0, !- Minute 18
+ 0.052687315, !- Value Until Time 18
+ 19, !- Hour 19
+ 0, !- Minute 19
+ 0.057270133, !- Value Until Time 19
+ 20, !- Hour 20
+ 0, !- Minute 20
+ 0.063348741, !- Value Until Time 20
+ 21, !- Hour 21
+ 0, !- Minute 21
+ 0.063698685, !- Value Until Time 21
+ 22, !- Hour 22
+ 0, !- Minute 22
+ 0.063840708, !- Value Until Time 22
+ 23, !- Hour 23
+ 0, !- Minute 23
+ 0.063848256, !- Value Until Time 23
+ 24, !- Hour 24
+ 0, !- Minute 24
+ 0.044653098; !- Value Until Time 24
+
+OS:Schedule:Day,
+ {e769f520-940a-425b-89cf-2275667edee3}, !- Handle
+ Office BLDG_LIGHT_EndUseData Winter Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0; !- Value Until Time 1
+
+OS:Schedule:Ruleset,
+ {f2cb7f1a-8571-497b-be52-e9666898f691}, !- Handle
+ Office BLDG_EQUIP_EndUseData, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {d7f3a469-f63e-48a7-bd8d-6900da586730}, !- Default Day Schedule Name
+ {f1a34ef8-0378-48bd-8761-b7f601b67da9}, !- Summer Design Day Schedule Name
+ {b866c787-25f9-4608-916f-2136ed59939e}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {d7f3a469-f63e-48a7-bd8d-6900da586730}, !- Handle
+ Office BLDG_EQUIP_EndUseData Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.5397, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.5806, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.5802, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.5631, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.547, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.5373, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.5386, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.598, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.6852, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.7808, !- Value Until Time 10
+ 11, !- Hour 11
+ 0, !- Minute 11
+ 0.8654, !- Value Until Time 11
+ 12, !- Hour 12
+ 0, !- Minute 12
+ 0.8867, !- Value Until Time 12
+ 13, !- Hour 13
+ 0, !- Minute 13
+ 0.8819, !- Value Until Time 13
+ 14, !- Hour 14
+ 0, !- Minute 14
+ 0.8207, !- Value Until Time 14
+ 15, !- Hour 15
+ 0, !- Minute 15
+ 0.7807, !- Value Until Time 15
+ 16, !- Hour 16
+ 0, !- Minute 16
+ 0.7353, !- Value Until Time 16
+ 17, !- Hour 17
+ 0, !- Minute 17
+ 0.6702, !- Value Until Time 17
+ 18, !- Hour 18
+ 0, !- Minute 18
+ 0.6048, !- Value Until Time 18
+ 19, !- Hour 19
+ 0, !- Minute 19
+ 0.566, !- Value Until Time 19
+ 20, !- Hour 20
+ 0, !- Minute 20
+ 0.5741, !- Value Until Time 20
+ 21, !- Hour 21
+ 0, !- Minute 21
+ 0.6127, !- Value Until Time 21
+ 22, !- Hour 22
+ 0, !- Minute 22
+ 0.6583, !- Value Until Time 22
+ 23, !- Hour 23
+ 0, !- Minute 23
+ 0.6734, !- Value Until Time 23
+ 24, !- Hour 24
+ 0, !- Minute 24
+ 0.61899; !- Value Until Time 24
+
+OS:Schedule:Rule,
+ {cdaf648e-4c6a-41e5-a3a5-40ee55a4fcdc}, !- Handle
+ Schedule Rule 7, !- Name
+ {f2cb7f1a-8571-497b-be52-e9666898f691}, !- Schedule Ruleset Name
+ 2, !- Rule Order
+ {47839954-c307-4355-a9a3-ff485e545735}, !- Day Schedule Name
+ , !- Apply Sunday
+ Yes, !- Apply Monday
+ Yes, !- Apply Tuesday
+ Yes, !- Apply Wednesday
+ Yes, !- Apply Thursday
+ Yes, !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {47839954-c307-4355-a9a3-ff485e545735}, !- Handle
+ Office BLDG_EQUIP_EndUseData Default|Wkdy Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.5397, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.5806, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.5802, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.5631, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.547, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.5373, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.5386, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.598, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.6852, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.7808, !- Value Until Time 10
+ 11, !- Hour 11
+ 0, !- Minute 11
+ 0.8654, !- Value Until Time 11
+ 12, !- Hour 12
+ 0, !- Minute 12
+ 0.8867, !- Value Until Time 12
+ 13, !- Hour 13
+ 0, !- Minute 13
+ 0.8819, !- Value Until Time 13
+ 14, !- Hour 14
+ 0, !- Minute 14
+ 0.8207, !- Value Until Time 14
+ 15, !- Hour 15
+ 0, !- Minute 15
+ 0.7807, !- Value Until Time 15
+ 16, !- Hour 16
+ 0, !- Minute 16
+ 0.7353, !- Value Until Time 16
+ 17, !- Hour 17
+ 0, !- Minute 17
+ 0.6702, !- Value Until Time 17
+ 18, !- Hour 18
+ 0, !- Minute 18
+ 0.6048, !- Value Until Time 18
+ 19, !- Hour 19
+ 0, !- Minute 19
+ 0.566, !- Value Until Time 19
+ 20, !- Hour 20
+ 0, !- Minute 20
+ 0.5741, !- Value Until Time 20
+ 21, !- Hour 21
+ 0, !- Minute 21
+ 0.6127, !- Value Until Time 21
+ 22, !- Hour 22
+ 0, !- Minute 22
+ 0.6583, !- Value Until Time 22
+ 23, !- Hour 23
+ 0, !- Minute 23
+ 0.6734, !- Value Until Time 23
+ 24, !- Hour 24
+ 0, !- Minute 24
+ 0.61899; !- Value Until Time 24
+
+OS:Schedule:Rule,
+ {57179161-bed0-4351-8a4a-b889585b4689}, !- Handle
+ Schedule Rule 8, !- Name
+ {f2cb7f1a-8571-497b-be52-e9666898f691}, !- Schedule Ruleset Name
+ 1, !- Rule Order
+ {5924910a-35cc-49bd-a53a-03ca65df439d}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ Yes, !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {5924910a-35cc-49bd-a53a-03ca65df439d}, !- Handle
+ Office BLDG_EQUIP_EndUseData Sat Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.6056, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.5696, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.5527, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.5472, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.5466, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.5455, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.5418, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.532, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.4942, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.4517, !- Value Until Time 10
+ 11, !- Hour 11
+ 0, !- Minute 11
+ 0.4411, !- Value Until Time 11
+ 12, !- Hour 12
+ 0, !- Minute 12
+ 0.4497, !- Value Until Time 12
+ 13, !- Hour 13
+ 0, !- Minute 13
+ 0.4629, !- Value Until Time 13
+ 14, !- Hour 14
+ 0, !- Minute 14
+ 0.4735, !- Value Until Time 14
+ 15, !- Hour 15
+ 0, !- Minute 15
+ 0.4944, !- Value Until Time 15
+ 16, !- Hour 16
+ 0, !- Minute 16
+ 0.4948, !- Value Until Time 16
+ 17, !- Hour 17
+ 0, !- Minute 17
+ 0.4918, !- Value Until Time 17
+ 18, !- Hour 18
+ 0, !- Minute 18
+ 0.5029, !- Value Until Time 18
+ 19, !- Hour 19
+ 0, !- Minute 19
+ 0.5268, !- Value Until Time 19
+ 20, !- Hour 20
+ 0, !- Minute 20
+ 0.5597, !- Value Until Time 20
+ 21, !- Hour 21
+ 0, !- Minute 21
+ 0.5945, !- Value Until Time 21
+ 22, !- Hour 22
+ 0, !- Minute 22
+ 0.6217, !- Value Until Time 22
+ 23, !- Hour 23
+ 0, !- Minute 23
+ 0.6288, !- Value Until Time 23
+ 24, !- Hour 24
+ 0, !- Minute 24
+ 0.5996; !- Value Until Time 24
+
+OS:Schedule:Day,
+ {f1a34ef8-0378-48bd-8761-b7f601b67da9}, !- Handle
+ Office BLDG_EQUIP_EndUseData Summer Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 1; !- Value Until Time 1
+
+OS:Schedule:Rule,
+ {e30ea4fb-608a-40de-a38e-d37e14666b51}, !- Handle
+ Schedule Rule 9, !- Name
+ {f2cb7f1a-8571-497b-be52-e9666898f691}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {18e051eb-82a3-42bb-a368-2cb796cfc145}, !- Day Schedule Name
+ Yes, !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {18e051eb-82a3-42bb-a368-2cb796cfc145}, !- Handle
+ Office BLDG_EQUIP_EndUseData Sun Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 1, !- Hour 1
+ 0, !- Minute 1
+ 0.5757, !- Value Until Time 1
+ 2, !- Hour 2
+ 0, !- Minute 2
+ 0.5529, !- Value Until Time 2
+ 3, !- Hour 3
+ 0, !- Minute 3
+ 0.5593, !- Value Until Time 3
+ 4, !- Hour 4
+ 0, !- Minute 4
+ 0.5739, !- Value Until Time 4
+ 5, !- Hour 5
+ 0, !- Minute 5
+ 0.5819, !- Value Until Time 5
+ 6, !- Hour 6
+ 0, !- Minute 6
+ 0.575, !- Value Until Time 6
+ 7, !- Hour 7
+ 0, !- Minute 7
+ 0.5487, !- Value Until Time 7
+ 8, !- Hour 8
+ 0, !- Minute 8
+ 0.5102, !- Value Until Time 8
+ 9, !- Hour 9
+ 0, !- Minute 9
+ 0.4877, !- Value Until Time 9
+ 10, !- Hour 10
+ 0, !- Minute 10
+ 0.4566, !- Value Until Time 10
+ 11, !- Hour 11
+ 0, !- Minute 11
+ 0.4489, !- Value Until Time 11
+ 12, !- Hour 12
+ 0, !- Minute 12
+ 0.4522, !- Value Until Time 12
+ 13, !- Hour 13
+ 0, !- Minute 13
+ 0.4743, !- Value Until Time 13
+ 14, !- Hour 14
+ 0, !- Minute 14
+ 0.4702, !- Value Until Time 14
+ 15, !- Hour 15
+ 0, !- Minute 15
+ 0.4726, !- Value Until Time 15
+ 16, !- Hour 16
+ 0, !- Minute 16
+ 0.4597, !- Value Until Time 16
+ 17, !- Hour 17
+ 0, !- Minute 17
+ 0.4585, !- Value Until Time 17
+ 18, !- Hour 18
+ 0, !- Minute 18
+ 0.4713, !- Value Until Time 18
+ 19, !- Hour 19
+ 0, !- Minute 19
+ 0.499, !- Value Until Time 19
+ 20, !- Hour 20
+ 0, !- Minute 20
+ 0.5466, !- Value Until Time 20
+ 21, !- Hour 21
+ 0, !- Minute 21
+ 0.5992, !- Value Until Time 21
+ 22, !- Hour 22
+ 0, !- Minute 22
+ 0.6383, !- Value Until Time 22
+ 23, !- Hour 23
+ 0, !- Minute 23
+ 0.6375, !- Value Until Time 23
+ 24, !- Hour 24
+ 0, !- Minute 24
+ 0.56343; !- Value Until Time 24
+
+OS:Schedule:Day,
+ {b866c787-25f9-4608-916f-2136ed59939e}, !- Handle
+ Office BLDG_EQUIP_EndUseData Winter Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0; !- Value Until Time 1
+
+OS:Schedule:Ruleset,
+ {090a79f1-a351-41bf-9f75-25c9635fd1f2}, !- Handle
+ Small Office Infil Quarter On, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {f569c352-e5b9-4b46-9b13-6f587481ab17}, !- Default Day Schedule Name
+ {f6a8d10d-3822-4fe1-99bd-ca3a12be97f8}, !- Summer Design Day Schedule Name
+ {4084f12c-af1e-4bf9-b03e-bd53a86a735c}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {f569c352-e5b9-4b46-9b13-6f587481ab17}, !- Handle
+ Small Office Infil Quarter On Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 1, !- Value Until Time 1
+ 22, !- Hour 2
+ 0, !- Minute 2
+ 0.25, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 1; !- Value Until Time 3
+
+OS:Schedule:Day,
+ {f6a8d10d-3822-4fe1-99bd-ca3a12be97f8}, !- Handle
+ Small Office Infil Quarter On Summer Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 1, !- Value Until Time 1
+ 22, !- Hour 2
+ 0, !- Minute 2
+ 0.25, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 1; !- Value Until Time 3
+
+OS:Schedule:Rule,
+ {afcdd912-9782-4f09-9146-e3876d5e92a7}, !- Handle
+ Schedule Rule 10, !- Name
+ {090a79f1-a351-41bf-9f75-25c9635fd1f2}, !- Schedule Ruleset Name
+ 1, !- Rule Order
+ {137d897e-6db0-4ccc-803f-034b23cc170c}, !- Day Schedule Name
+ Yes, !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {137d897e-6db0-4ccc-803f-034b23cc170c}, !- Handle
+ Small Office Infil Quarter On Sun Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 1; !- Value Until Time 1
+
+OS:Schedule:Day,
+ {4084f12c-af1e-4bf9-b03e-bd53a86a735c}, !- Handle
+ Small Office Infil Quarter On Winter Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 1, !- Value Until Time 1
+ 18, !- Hour 2
+ 0, !- Minute 2
+ 0.25, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 1; !- Value Until Time 3
+
+OS:Schedule:Rule,
+ {4797ee74-1e7e-4da9-9288-47889d6c2cbc}, !- Handle
+ Schedule Rule 11, !- Name
+ {090a79f1-a351-41bf-9f75-25c9635fd1f2}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {c0a986b4-1f9c-4432-84aa-bb8f85cae2b9}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ Yes, !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {c0a986b4-1f9c-4432-84aa-bb8f85cae2b9}, !- Handle
+ Small Office Infil Quarter On WntrDsn|Sat Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 1, !- Value Until Time 1
+ 18, !- Hour 2
+ 0, !- Minute 2
+ 0.25, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 1; !- Value Until Time 3
+
+OS:Construction:FfactorGroundFloor,
+ {13e6c855-3a65-406b-b8da-78b7bc6759d6}, !- Handle
+ Foundation F 1.26W/m*K Perim 83.29m Area 325.16m2, !- Name
+ 1.26343630645111, !- F-Factor {W/m-K}
+ 325.160640000001, !- Area {m2}
+ 83.2872158257196; !- PerimeterExposed {m}
+
+OS:DefaultConstructionSet,
+ {2d4d64c5-7784-4fda-a5f5-513459437905}, !- Handle
+ ComStock DOE Ref Pre-1980 - Office - ASHRAE 169-2013-5B, !- Name
+ {32d9b003-4036-435a-bc2c-0a08ba7363c4}, !- Default Exterior Surface Constructions Name
+ {3545bed8-9ad5-452b-9764-46bd48cc8aba}, !- Default Interior Surface Constructions Name
+ {f16031c9-c8c4-43bd-9dd0-bc89eb1eb052}, !- Default Ground Contact Surface Constructions Name
+ {5410f752-e721-411e-9fad-e944f156f41d}, !- Default Exterior SubSurface Constructions Name
+ {0303b476-7e20-4012-8a9a-df611142bf80}, !- Default Interior SubSurface Constructions Name
+ {1d78b9b7-307f-49b6-86f8-e10df59b9db9}, !- Interior Partition Construction Name
+ , !- Space Shading Construction Name
+ , !- Building Shading Construction Name
+ , !- Site Shading Construction Name
+ ; !- Adiabatic Surface Construction Name
+
+OS:DefaultSurfaceConstructions,
+ {32d9b003-4036-435a-bc2c-0a08ba7363c4}, !- Handle
+ Default Surface Constructions 1, !- Name
+ {e52bcfcb-0f81-4397-9692-398c470fef66}, !- Floor Construction Name
+ {913bf434-7537-4e7f-912b-af553cf076a8}, !- Wall Construction Name
+ {b5fe2656-4aad-44ec-8f4a-81ea39f4a871}; !- Roof Ceiling Construction Name
+
+OS:Construction,
+ {e52bcfcb-0f81-4397-9692-398c470fef66}, !- Handle
+ Typical Insulated Exterior Mass Floor, !- Name
+ , !- Surface Rendering Name
+ {6e8a037e-d01d-4b89-bfac-1a10c2955410}, !- Layer 1
+ {14ecbd0a-d02e-4c6d-9e68-ecc89392cb6a}; !- Layer 2
+
+OS:Material:NoMass,
+ {b42b5042-e52e-48cf-910d-b9562cb2b53e}, !- Handle
+ Typical Insulation R-3.82, !- Name
+ Smooth, !- Roughness
+ 0.673215966942562, !- Thermal Resistance {m2-K/W}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Material,
+ {6e8a037e-d01d-4b89-bfac-1a10c2955410}, !- Handle
+ 4 in. Normalweight Concrete Floor, !- Name
+ MediumRough, !- Roughness
+ 0.1016, !- Thickness {m}
+ 2.31, !- Conductivity {W/m-K}
+ 2321.99999999999, !- Density {kg/m3}
+ 831.999999999997, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Material:NoMass,
+ {14ecbd0a-d02e-4c6d-9e68-ecc89392cb6a}, !- Handle
+ Typical Carpet Pad, !- Name
+ Smooth, !- Roughness
+ 0.216479986995276, !- Thermal Resistance {m2-K/W}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.8; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {017b0be8-c3ab-44ce-a034-43b59f6f04fa}, !- Handle
+ {e52bcfcb-0f81-4397-9692-398c470fef66}, !- Construction Name
+ ExteriorFloor, !- Intended Surface Type
+ Mass; !- Standards Construction Type
+
+OS:Construction,
+ {913bf434-7537-4e7f-912b-af553cf076a8}, !- Handle
+ Typical Insulated Exterior Mass Wall R-6.21, !- Name
+ , !- Surface Rendering Name
+ {8f5d7d17-c063-42c3-a65c-e1e4f3fb8233}, !- Layer 1
+ {effbbb2d-afe0-484a-8155-77b05b7846a0}, !- Layer 2
+ {b42b5042-e52e-48cf-910d-b9562cb2b53e}, !- Layer 3
+ {ce2f72e5-e930-42ef-8582-0f9e0279c550}; !- Layer 4
+
+OS:Material,
+ {8f5d7d17-c063-42c3-a65c-e1e4f3fb8233}, !- Handle
+ 1IN Stucco, !- Name
+ Smooth, !- Roughness
+ 0.0253, !- Thickness {m}
+ 0.691799999999999, !- Conductivity {W/m-K}
+ 1858, !- Density {kg/m3}
+ 836.999999999999, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.92; !- Visible Absorptance
+
+OS:Material,
+ {effbbb2d-afe0-484a-8155-77b05b7846a0}, !- Handle
+ 8IN CONCRETE HW RefBldg, !- Name
+ Rough, !- Roughness
+ 0.2032, !- Thickness {m}
+ 1.311, !- Conductivity {W/m-K}
+ 2240, !- Density {kg/m3}
+ 836.800000000001, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Material,
+ {ce2f72e5-e930-42ef-8582-0f9e0279c550}, !- Handle
+ 1/2IN Gypsum, !- Name
+ Smooth, !- Roughness
+ 0.0127, !- Thickness {m}
+ 0.16, !- Conductivity {W/m-K}
+ 784.9, !- Density {kg/m3}
+ 830.000000000001, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.4, !- Solar Absorptance
+ 0.4; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {d38e6dba-c4ef-4a4a-8ae2-6adb4cc5cb2c}, !- Handle
+ {913bf434-7537-4e7f-912b-af553cf076a8}, !- Construction Name
+ ExteriorWall, !- Intended Surface Type
+ Mass; !- Standards Construction Type
+
+OS:Construction,
+ {b5fe2656-4aad-44ec-8f4a-81ea39f4a871}, !- Handle
+ Typical IEAD Roof R-13.16, !- Name
+ , !- Surface Rendering Name
+ {5ef34cb0-9fe9-4560-b71d-608593cf084a}, !- Layer 1
+ {39e18fdb-601f-4a7b-accd-288065a06e81}, !- Layer 2
+ {b990dbff-64ca-469b-b057-806c4023155c}; !- Layer 3
+
+OS:Material,
+ {5ef34cb0-9fe9-4560-b71d-608593cf084a}, !- Handle
+ Roof Membrane, !- Name
+ VeryRough, !- Roughness
+ 0.0095, !- Thickness {m}
+ 0.16, !- Conductivity {W/m-K}
+ 1121.29, !- Density {kg/m3}
+ 1460, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Material:NoMass,
+ {39e18fdb-601f-4a7b-accd-288065a06e81}, !- Handle
+ Typical Insulation R-12.04, !- Name
+ Smooth, !- Roughness
+ 2.12048064786099, !- Thermal Resistance {m2-K/W}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Material,
+ {b990dbff-64ca-469b-b057-806c4023155c}, !- Handle
+ Metal Roof Surface, !- Name
+ Smooth, !- Roughness
+ 0.000799999999999998, !- Thickness {m}
+ 45.2799999999999, !- Conductivity {W/m-K}
+ 7823.99999999999, !- Density {kg/m3}
+ 499.999999999996, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {bde9904f-1d6b-44c9-8d8c-609b8988642e}, !- Handle
+ {b5fe2656-4aad-44ec-8f4a-81ea39f4a871}, !- Construction Name
+ ExteriorRoof, !- Intended Surface Type
+ IEAD; !- Standards Construction Type
+
+OS:DefaultSurfaceConstructions,
+ {3545bed8-9ad5-452b-9764-46bd48cc8aba}, !- Handle
+ Default Surface Constructions 2, !- Name
+ {cfc2fd01-eac1-412e-8cf4-19516892f854}, !- Floor Construction Name
+ {c1e60108-749b-489d-8bbb-51ee90f99ae3}, !- Wall Construction Name
+ {bd0a36ec-cccd-4518-b6e6-ed9e8461c7c3}; !- Roof Ceiling Construction Name
+
+OS:Construction,
+ {cfc2fd01-eac1-412e-8cf4-19516892f854}, !- Handle
+ Typical Interior Floor, !- Name
+ , !- Surface Rendering Name
+ {89f4529a-9f2a-4f93-9d8a-65cb5ced96e5}, !- Layer 1
+ {ec74f628-4d78-42a2-a542-cda843f4aa27}; !- Layer 2
+
+OS:Material,
+ {89f4529a-9f2a-4f93-9d8a-65cb5ced96e5}, !- Handle
+ 100mm Normalweight concrete floor, !- Name
+ MediumRough, !- Roughness
+ 0.1016, !- Thickness {m}
+ 2.31044676686054, !- Conductivity {W/m-K}
+ 2322.00146636525, !- Density {kg/m3}
+ 832.5567858096, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Material:NoMass,
+ {ec74f628-4d78-42a2-a542-cda843f4aa27}, !- Handle
+ CP02 CARPET PAD, !- Name
+ Smooth, !- Roughness
+ 0.216479986995276, !- Thermal Resistance {m2-K/W}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.8; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {39514f5d-4ae7-4dd7-aa21-77943c3e169c}, !- Handle
+ {cfc2fd01-eac1-412e-8cf4-19516892f854}, !- Construction Name
+ InteriorFloor, !- Intended Surface Type
+ ; !- Standards Construction Type
+
+OS:Construction,
+ {c1e60108-749b-489d-8bbb-51ee90f99ae3}, !- Handle
+ Typical Interior Wall, !- Name
+ , !- Surface Rendering Name
+ {7ff61b74-57ab-49a5-8563-135ec3fe148e}, !- Layer 1
+ {7ff61b74-57ab-49a5-8563-135ec3fe148e}; !- Layer 2
+
+OS:Material,
+ {7ff61b74-57ab-49a5-8563-135ec3fe148e}, !- Handle
+ G01 13mm gypsum board, !- Name
+ Smooth, !- Roughness
+ 0.0127, !- Thickness {m}
+ 0.160030944416258, !- Conductivity {W/m-K}
+ 800.000505207667, !- Density {kg/m3}
+ 1090.7294438736, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.5; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {48a134e3-c4cc-4aaf-b2cc-d48fa5956a72}, !- Handle
+ {c1e60108-749b-489d-8bbb-51ee90f99ae3}, !- Construction Name
+ InteriorWall, !- Intended Surface Type
+ ; !- Standards Construction Type
+
+OS:Construction,
+ {bd0a36ec-cccd-4518-b6e6-ed9e8461c7c3}, !- Handle
+ Typical Interior Ceiling, !- Name
+ , !- Surface Rendering Name
+ {ec74f628-4d78-42a2-a542-cda843f4aa27}, !- Layer 1
+ {89f4529a-9f2a-4f93-9d8a-65cb5ced96e5}; !- Layer 2
+
+OS:StandardsInformation:Construction,
+ {4dcdd856-7a24-4cd2-9ea1-1b48f879a9e9}, !- Handle
+ {bd0a36ec-cccd-4518-b6e6-ed9e8461c7c3}, !- Construction Name
+ InteriorCeiling, !- Intended Surface Type
+ ; !- Standards Construction Type
+
+OS:DefaultSurfaceConstructions,
+ {f16031c9-c8c4-43bd-9dd0-bc89eb1eb052}, !- Handle
+ Default Surface Constructions 3, !- Name
+ {e274cfb9-e807-4723-b298-2f4f7ba9cf92}, !- Floor Construction Name
+ {d70354a7-be5c-4f5a-82b3-d86ad1f7178d}, !- Wall Construction Name
+ ; !- Roof Ceiling Construction Name
+
+OS:Construction,
+ {e274cfb9-e807-4723-b298-2f4f7ba9cf92}, !- Handle
+ Typical Insulated Carpeted 6in Slab Floor, !- Name
+ , !- Surface Rendering Name
+ {1f0b51b8-7abe-4639-b9a5-4f45444fee76}, !- Layer 1
+ {14ecbd0a-d02e-4c6d-9e68-ecc89392cb6a}; !- Layer 2
+
+OS:Material:NoMass,
+ {74bc0cd9-a986-4138-923d-027c806a0263}, !- Handle
+ Typical Insulation, !- Name
+ Smooth, !- Roughness
+ 0.0282222222222221, !- Thermal Resistance {m2-K/W}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Material,
+ {1f0b51b8-7abe-4639-b9a5-4f45444fee76}, !- Handle
+ 6 in. Normalweight Concrete Floor, !- Name
+ MediumRough, !- Roughness
+ 0.1524, !- Thickness {m}
+ 2.31, !- Conductivity {W/m-K}
+ 2321.99999999999, !- Density {kg/m3}
+ 831.999999999997, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {f199a412-7c2a-452e-9106-24868deec9d3}, !- Handle
+ {e274cfb9-e807-4723-b298-2f4f7ba9cf92}, !- Construction Name
+ GroundContactFloor, !- Intended Surface Type
+ Mass; !- Standards Construction Type
+
+OS:Construction,
+ {d70354a7-be5c-4f5a-82b3-d86ad1f7178d}, !- Handle
+ Typical Insulated Basement Mass Wall, !- Name
+ , !- Surface Rendering Name
+ {dd31cfb0-cf9a-4789-9046-087f5fa08062}; !- Layer 1
+
+OS:Material,
+ {dd31cfb0-cf9a-4789-9046-087f5fa08062}, !- Handle
+ 8 in. Concrete Block Basement Wall, !- Name
+ MediumRough, !- Roughness
+ 0.2032, !- Thickness {m}
+ 1.326, !- Conductivity {W/m-K}
+ 1841.99999999999, !- Density {kg/m3}
+ 911.999999999999, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {ffc5d468-5992-4621-82bf-4daed312721d}, !- Handle
+ {d70354a7-be5c-4f5a-82b3-d86ad1f7178d}, !- Construction Name
+ GroundContactWall, !- Intended Surface Type
+ Mass; !- Standards Construction Type
+
+OS:DefaultSubSurfaceConstructions,
+ {5410f752-e721-411e-9fad-e944f156f41d}, !- Handle
+ Default Sub Surface Constructions 1, !- Name
+ {ffb65bfb-a4d6-4162-9fbb-522a3a3767b6}, !- Fixed Window Construction Name
+ {ffb65bfb-a4d6-4162-9fbb-522a3a3767b6}, !- Operable Window Construction Name
+ {f454cda6-56a3-46ae-ba24-8c4cdaa3848c}, !- Door Construction Name
+ {b55df934-eca5-40e9-acf9-885609148ebf}, !- Glass Door Construction Name
+ {76a9ae1b-9cb2-4387-93ca-0a4f6fe536d9}, !- Overhead Door Construction Name
+ , !- Skylight Construction Name
+ {2877298f-4d59-46f8-a12f-621c30117db1}, !- Tubular Daylight Dome Construction Name
+ {2877298f-4d59-46f8-a12f-621c30117db1}; !- Tubular Daylight Diffuser Construction Name
+
+OS:Construction,
+ {ffb65bfb-a4d6-4162-9fbb-522a3a3767b6}, !- Handle
+ Simple Glazing U 0.62 SHGC 0.41, !- Name
+ , !- Surface Rendering Name
+ {d56413b2-72a4-4199-9e4b-c3a461d3c0f9}; !- Layer 1
+
+OS:WindowMaterial:SimpleGlazingSystem,
+ {d56413b2-72a4-4199-9e4b-c3a461d3c0f9}, !- Handle
+ Simple Glazing U 0.62 SHGC 0.41, !- Name
+ 3.52052327149036, !- U-Factor {W/m2-K}
+ 0.41, !- Solar Heat Gain Coefficient
+ 0.81; !- Visible Transmittance
+
+OS:StandardsInformation:Construction,
+ {a8580861-fc94-46c3-8e44-19e9cace91f2}, !- Handle
+ {ffb65bfb-a4d6-4162-9fbb-522a3a3767b6}, !- Construction Name
+ ExteriorWindow, !- Intended Surface Type
+ Metal framing (all other), !- Standards Construction Type
+ , !- Perturbable Layer
+ , !- Perturbable Layer Type
+ , !- Other Perturbable Layer Type
+ , !- Construction Standard
+ , !- Construction Standard Source
+ , !- Fenestration Type
+ , !- Fenestration Assembly Context
+ , !- Fenestration Number of Panes
+ Metal Framing; !- Fenestration Frame Type
+
+OS:Construction,
+ {f454cda6-56a3-46ae-ba24-8c4cdaa3848c}, !- Handle
+ Typical Insulated Metal Door, !- Name
+ , !- Surface Rendering Name
+ {47452380-ba0e-4f6f-a321-392aced50aaa}, !- Layer 1
+ {74bc0cd9-a986-4138-923d-027c806a0263}; !- Layer 2
+
+OS:Material,
+ {47452380-ba0e-4f6f-a321-392aced50aaa}, !- Handle
+ F08 Metal surface, !- Name
+ Smooth, !- Roughness
+ 0.0008, !- Thickness {m}
+ 45.2800000000001, !- Conductivity {W/m-K}
+ 7823.99999999999, !- Density {kg/m3}
+ 500, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {ad4bb192-b01c-48df-a403-d3a6662695f5}, !- Handle
+ {f454cda6-56a3-46ae-ba24-8c4cdaa3848c}, !- Construction Name
+ ExteriorDoor, !- Intended Surface Type
+ ; !- Standards Construction Type
+
+OS:Construction,
+ {b55df934-eca5-40e9-acf9-885609148ebf}, !- Handle
+ U 0.88 SHGC 0.16 Sgl Ref-A-L Clr 6mm, !- Name
+ , !- Surface Rendering Name
+ {eae4043c-3774-4b34-af5b-055f7694aa71}; !- Layer 1
+
+OS:WindowMaterial:Glazing,
+ {eae4043c-3774-4b34-af5b-055f7694aa71}, !- Handle
+ REF A CLEAR LO 6MM, !- Name
+ SpectralAverage, !- Optical Data Type
+ , !- Window Glass Spectral Data Set Name
+ 0.00599999999999998, !- Thickness {m}
+ 0.066, !- Solar Transmittance at Normal Incidence
+ 0.341, !- Front Side Solar Reflectance at Normal Incidence
+ 0.493, !- Back Side Solar Reflectance at Normal Incidence
+ 0.08, !- Visible Transmittance at Normal Incidence
+ 0.41, !- Front Side Visible Reflectance at Normal Incidence
+ 0.37, !- Back Side Visible Reflectance at Normal Incidence
+ 0, !- Infrared Transmittance at Normal Incidence
+ 0.84, !- Front Side Infrared Hemispherical Emissivity
+ 0.4, !- Back Side Infrared Hemispherical Emissivity
+ 0.9, !- Conductivity {W/m-K}
+ 1, !- Dirt Correction Factor for Solar and Visible Transmittance
+ No; !- Solar Diffusing
+
+OS:StandardsInformation:Construction,
+ {a35b5133-b6e8-42b8-acfd-14f37ecf6131}, !- Handle
+ {b55df934-eca5-40e9-acf9-885609148ebf}, !- Construction Name
+ ExteriorWindow, !- Intended Surface Type
+ Metal framing (all other), !- Standards Construction Type
+ , !- Perturbable Layer
+ , !- Perturbable Layer Type
+ , !- Other Perturbable Layer Type
+ , !- Construction Standard
+ , !- Construction Standard Source
+ , !- Fenestration Type
+ , !- Fenestration Assembly Context
+ , !- Fenestration Number of Panes
+ Metal Framing; !- Fenestration Frame Type
+
+OS:Construction,
+ {76a9ae1b-9cb2-4387-93ca-0a4f6fe536d9}, !- Handle
+ Typical Overhead Door, !- Name
+ , !- Surface Rendering Name
+ {74bc0cd9-a986-4138-923d-027c806a0263}; !- Layer 1
+
+OS:StandardsInformation:Construction,
+ {320c73ee-d042-4266-b8f1-28baa0b6c85b}, !- Handle
+ {76a9ae1b-9cb2-4387-93ca-0a4f6fe536d9}, !- Construction Name
+ ExteriorDoor, !- Intended Surface Type
+ RollUp; !- Standards Construction Type
+
+OS:Construction,
+ {2877298f-4d59-46f8-a12f-621c30117db1}, !- Handle
+ Typical Interior Window, !- Name
+ , !- Surface Rendering Name
+ {46469dab-3c42-4ac1-922f-e14e0e857773}; !- Layer 1
+
+OS:WindowMaterial:Glazing,
+ {46469dab-3c42-4ac1-922f-e14e0e857773}, !- Handle
+ Clear 3mm, !- Name
+ SpectralAverage, !- Optical Data Type
+ , !- Window Glass Spectral Data Set Name
+ 0.00299999999999999, !- Thickness {m}
+ 0.837, !- Solar Transmittance at Normal Incidence
+ 0.075, !- Front Side Solar Reflectance at Normal Incidence
+ 0.075, !- Back Side Solar Reflectance at Normal Incidence
+ 0.898, !- Visible Transmittance at Normal Incidence
+ 0.081, !- Front Side Visible Reflectance at Normal Incidence
+ 0.081, !- Back Side Visible Reflectance at Normal Incidence
+ 0, !- Infrared Transmittance at Normal Incidence
+ 0.84, !- Front Side Infrared Hemispherical Emissivity
+ 0.84, !- Back Side Infrared Hemispherical Emissivity
+ 0.9, !- Conductivity {W/m-K}
+ 1, !- Dirt Correction Factor for Solar and Visible Transmittance
+ No; !- Solar Diffusing
+
+OS:StandardsInformation:Construction,
+ {5a165d63-0c53-41d3-9652-8ba600ce1b08}, !- Handle
+ {2877298f-4d59-46f8-a12f-621c30117db1}, !- Construction Name
+ InteriorWindow, !- Intended Surface Type
+ ; !- Standards Construction Type
+
+OS:DefaultSubSurfaceConstructions,
+ {0303b476-7e20-4012-8a9a-df611142bf80}, !- Handle
+ Default Sub Surface Constructions 2, !- Name
+ {2877298f-4d59-46f8-a12f-621c30117db1}, !- Fixed Window Construction Name
+ {2877298f-4d59-46f8-a12f-621c30117db1}, !- Operable Window Construction Name
+ {446734f1-1fae-4192-ac90-513219b59166}, !- Door Construction Name
+ , !- Glass Door Construction Name
+ , !- Overhead Door Construction Name
+ , !- Skylight Construction Name
+ , !- Tubular Daylight Dome Construction Name
+ ; !- Tubular Daylight Diffuser Construction Name
+
+OS:Construction,
+ {446734f1-1fae-4192-ac90-513219b59166}, !- Handle
+ Typical Interior Door, !- Name
+ , !- Surface Rendering Name
+ {60e078db-69c1-4c10-ac14-391cd58d2bfc}; !- Layer 1
+
+OS:Material,
+ {60e078db-69c1-4c10-ac14-391cd58d2bfc}, !- Handle
+ G05 25mm wood, !- Name
+ MediumSmooth, !- Roughness
+ 0.0254, !- Thickness {m}
+ 0.15, !- Conductivity {W/m-K}
+ 608, !- Density {kg/m3}
+ 1630, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.5, !- Solar Absorptance
+ 0.5; !- Visible Absorptance
+
+OS:StandardsInformation:Construction,
+ {ffd574ac-306d-4235-921d-1c9c4d363f6a}, !- Handle
+ {446734f1-1fae-4192-ac90-513219b59166}, !- Construction Name
+ InteriorDoor, !- Intended Surface Type
+ ; !- Standards Construction Type
+
+OS:Construction,
+ {1d78b9b7-307f-49b6-86f8-e10df59b9db9}, !- Handle
+ Typical Interior Partition, !- Name
+ , !- Surface Rendering Name
+ {60e078db-69c1-4c10-ac14-391cd58d2bfc}; !- Layer 1
+
+OS:StandardsInformation:Construction,
+ {15e601e3-008a-4575-a3e3-68aa658e871d}, !- Handle
+ {1d78b9b7-307f-49b6-86f8-e10df59b9db9}, !- Construction Name
+ InteriorPartition, !- Intended Surface Type
+ ; !- Standards Construction Type
+
+OS:Schedule:Constant,
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Handle
+ Always On Discrete, !- Name
+ {4cf81f32-4306-4476-b782-d6b1f941f28f}, !- Schedule Type Limits Name
+ 1; !- Value
+
+OS:ScheduleTypeLimits,
+ {4cf81f32-4306-4476-b782-d6b1f941f28f}, !- Handle
+ OnOff, !- Name
+ 0, !- Lower Limit Value
+ 1, !- Upper Limit Value
+ Discrete, !- Numeric Type
+ Availability; !- Unit Type
+
+OS:SpaceInfiltration:DesignFlowRate,
+ {9b2c5abe-c45a-4478-a44c-c55b9283b389}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Infiltration, !- Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space or SpaceType Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Schedule Name
+ Flow/ExteriorArea, !- Design Flow Rate Calculation Method
+ , !- Design Flow Rate {m3/s}
+ , !- Flow per Space Floor Area {m3/s-m2}
+ 0.0004494919132, !- Flow per Exterior Surface Area {m3/s-m2}
+ , !- Air Changes per Hour {1/hr}
+ 0, !- Constant Term Coefficient
+ 0, !- Temperature Term Coefficient
+ 0.224, !- Velocity Term Coefficient
+ 0; !- Velocity Squared Term Coefficient
+
+OS:Exterior:Lights:Definition,
+ {e7cc302a-fac3-42dc-a089-0354c594868f}, !- Handle
+ Parking Areas and Drives Def (W/ft^2), !- Name
+ 0.18; !- Design Level {W}
+
+OS:Exterior:Lights,
+ {b3ebcdce-f3f7-47c3-addf-a67f1b577438}, !- Handle
+ Parking Areas and Drives, !- Name
+ {e7cc302a-fac3-42dc-a089-0354c594868f}, !- Exterior Lights Definition Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Schedule Name
+ AstronomicalClock, !- Control Option
+ 5670.00000000001, !- Multiplier
+ Parking Areas and Drives; !- End-Use Subcategory
+
+OS:Exterior:Lights:Definition,
+ {acf710a0-67bc-4ff7-83c7-e4edee7c3d4d}, !- Handle
+ Building Facades Def (W/ft^2), !- Name
+ 0.25; !- Design Level {W}
+
+OS:Exterior:Lights,
+ {22c69d0c-beef-4860-a191-6bf0dfb237a9}, !- Handle
+ Building Facades, !- Name
+ {acf710a0-67bc-4ff7-83c7-e4edee7c3d4d}, !- Exterior Lights Definition Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Schedule Name
+ AstronomicalClock, !- Control Option
+ 2732.52020425589, !- Multiplier
+ Building Facades; !- End-Use Subcategory
+
+OS:Exterior:Lights:Definition,
+ {755a3039-6f5a-40a6-b7cd-1ab645c7e6c5}, !- Handle
+ Main Entries Def (W/ft), !- Name
+ 30; !- Design Level {W}
+
+OS:Exterior:Lights,
+ {1eeeaa91-5249-4b81-9daa-cd511eebded8}, !- Handle
+ Main Entries, !- Name
+ {755a3039-6f5a-40a6-b7cd-1ab645c7e6c5}, !- Exterior Lights Definition Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Schedule Name
+ AstronomicalClock, !- Control Option
+ 8, !- Multiplier
+ Main Entries; !- End-Use Subcategory
+
+OS:Exterior:Lights:Definition,
+ {81d47270-0e9b-4025-8d84-b69216628628}, !- Handle
+ Other Doors Def (W/ft), !- Name
+ 25; !- Design Level {W}
+
+OS:Exterior:Lights,
+ {ab02fe71-c676-4676-9706-ac3e353ae235}, !- Handle
+ Other Doors, !- Name
+ {81d47270-0e9b-4025-8d84-b69216628628}, !- Exterior Lights Definition Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Schedule Name
+ AstronomicalClock, !- Control Option
+ 2.80000000000001, !- Multiplier
+ Other Doors; !- End-Use Subcategory
+
+OS:Schedule:Ruleset,
+ {523faf97-0fb7-4d65-97fd-12101be7312e}, !- Handle
+ OfficeSmall BLDG_SWH_SCH, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {20d18fd3-55dd-4119-a5ab-bd66247b3d37}, !- Default Day Schedule Name
+ {4c1d70c2-13b5-4d2f-871d-0a201235904c}, !- Summer Design Day Schedule Name
+ {63eadd40-5bba-458a-a1de-4683689607b5}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {20d18fd3-55dd-4119-a5ab-bd66247b3d37}, !- Handle
+ OfficeSmall BLDG_SWH_SCH Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0; !- Value Until Time 1
+
+OS:Schedule:Day,
+ {63eadd40-5bba-458a-a1de-4683689607b5}, !- Handle
+ OfficeSmall BLDG_SWH_SCH Winter Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 7, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 8, !- Hour 2
+ 0, !- Minute 2
+ 0.27, !- Value Until Time 2
+ 9, !- Hour 3
+ 0, !- Minute 3
+ 0.55, !- Value Until Time 3
+ 11, !- Hour 4
+ 0, !- Minute 4
+ 0.64, !- Value Until Time 4
+ 12, !- Hour 5
+ 0, !- Minute 5
+ 0.82, !- Value Until Time 5
+ 13, !- Hour 6
+ 0, !- Minute 6
+ 1, !- Value Until Time 6
+ 14, !- Hour 7
+ 0, !- Minute 7
+ 0.91, !- Value Until Time 7
+ 16, !- Hour 8
+ 0, !- Minute 8
+ 0.55, !- Value Until Time 8
+ 17, !- Hour 9
+ 0, !- Minute 9
+ 0.73, !- Value Until Time 9
+ 19, !- Hour 10
+ 0, !- Minute 10
+ 0.37, !- Value Until Time 10
+ 20, !- Hour 11
+ 0, !- Minute 11
+ 0.18, !- Value Until Time 11
+ 21, !- Hour 12
+ 0, !- Minute 12
+ 0.27, !- Value Until Time 12
+ 22, !- Hour 13
+ 0, !- Minute 13
+ 0.09, !- Value Until Time 13
+ 24, !- Hour 14
+ 0, !- Minute 14
+ 0; !- Value Until Time 14
+
+OS:Schedule:Day,
+ {4c1d70c2-13b5-4d2f-871d-0a201235904c}, !- Handle
+ OfficeSmall BLDG_SWH_SCH Summer Design Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 7, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 8, !- Hour 2
+ 0, !- Minute 2
+ 0.27, !- Value Until Time 2
+ 9, !- Hour 3
+ 0, !- Minute 3
+ 0.55, !- Value Until Time 3
+ 11, !- Hour 4
+ 0, !- Minute 4
+ 0.64, !- Value Until Time 4
+ 12, !- Hour 5
+ 0, !- Minute 5
+ 0.82, !- Value Until Time 5
+ 13, !- Hour 6
+ 0, !- Minute 6
+ 1, !- Value Until Time 6
+ 14, !- Hour 7
+ 0, !- Minute 7
+ 0.91, !- Value Until Time 7
+ 16, !- Hour 8
+ 0, !- Minute 8
+ 0.55, !- Value Until Time 8
+ 17, !- Hour 9
+ 0, !- Minute 9
+ 0.73, !- Value Until Time 9
+ 19, !- Hour 10
+ 0, !- Minute 10
+ 0.37, !- Value Until Time 10
+ 20, !- Hour 11
+ 0, !- Minute 11
+ 0.18, !- Value Until Time 11
+ 21, !- Hour 12
+ 0, !- Minute 12
+ 0.27, !- Value Until Time 12
+ 22, !- Hour 13
+ 0, !- Minute 13
+ 0.09, !- Value Until Time 13
+ 24, !- Hour 14
+ 0, !- Minute 14
+ 0; !- Value Until Time 14
+
+OS:Schedule:Rule,
+ {bfc16a17-63e3-4761-a757-d08dbb4ff1fc}, !- Handle
+ Schedule Rule 12, !- Name
+ {523faf97-0fb7-4d65-97fd-12101be7312e}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {91a4be84-6690-48dc-9de5-882796e883af}, !- Day Schedule Name
+ , !- Apply Sunday
+ Yes, !- Apply Monday
+ Yes, !- Apply Tuesday
+ Yes, !- Apply Wednesday
+ Yes, !- Apply Thursday
+ Yes, !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {91a4be84-6690-48dc-9de5-882796e883af}, !- Handle
+ OfficeSmall BLDG_SWH_SCH WntrDsn|SmrDsn|Wkdy Day, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 7, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 8, !- Hour 2
+ 0, !- Minute 2
+ 0.27, !- Value Until Time 2
+ 9, !- Hour 3
+ 0, !- Minute 3
+ 0.55, !- Value Until Time 3
+ 11, !- Hour 4
+ 0, !- Minute 4
+ 0.64, !- Value Until Time 4
+ 12, !- Hour 5
+ 0, !- Minute 5
+ 0.82, !- Value Until Time 5
+ 13, !- Hour 6
+ 0, !- Minute 6
+ 1, !- Value Until Time 6
+ 14, !- Hour 7
+ 0, !- Minute 7
+ 0.91, !- Value Until Time 7
+ 16, !- Hour 8
+ 0, !- Minute 8
+ 0.55, !- Value Until Time 8
+ 17, !- Hour 9
+ 0, !- Minute 9
+ 0.73, !- Value Until Time 9
+ 19, !- Hour 10
+ 0, !- Minute 10
+ 0.37, !- Value Until Time 10
+ 20, !- Hour 11
+ 0, !- Minute 11
+ 0.18, !- Value Until Time 11
+ 21, !- Hour 12
+ 0, !- Minute 12
+ 0.27, !- Value Until Time 12
+ 22, !- Hour 13
+ 0, !- Minute 13
+ 0.09, !- Value Until Time 13
+ 24, !- Hour 14
+ 0, !- Minute 14
+ 0; !- Value Until Time 14
+
+OS:WaterUse:Connections,
+ {8460a8df-44c6-4da5-99d9-babe3b1b1462}, !- Handle
+ Office WholeBuilding - Sm Office - ComStock DOE Ref Pre-1980 WUC 0.03gpm at 140F, !- Name
+ {ba34a2b8-da1e-48bc-8ae3-85e40f22c3bf}, !- Inlet Node Name
+ {b577f331-6c23-4c43-90e4-1c8f443dc10a}, !- Outlet Node Name
+ , !- Supply Water Storage Tank Name
+ , !- Reclamation Water Storage Tank Name
+ , !- Hot Water Supply Temperature Schedule Name
+ , !- Cold Water Supply Temperature Schedule Name
+ None, !- Drain Water Heat Exchanger Type
+ Plant, !- Drain Water Heat Exchanger Destination
+ , !- Drain Water Heat Exchanger U-Factor Times Area {W/K}
+ {c725894c-43c8-4e18-8c6e-be29b6116f59}; !- Water Use Equipment Name 1
+
+OS:WaterUse:Equipment:Definition,
+ {f4953159-aca5-4b84-87b1-8060db0f9b83}, !- Handle
+ Office WholeBuilding - Sm Office - ComStock DOE Ref Pre-1980 Service Water Use Def 0.03gpm, !- Name
+ , !- End-Use Subcategory
+ 2.00668563594296e-06, !- Peak Flow Rate {m3/s}
+ {93d0b10a-3452-4e29-af37-806e3b606820}, !- Target Temperature Schedule Name
+ {bc62fd2a-3bbb-4373-8518-f473eef07fcb}, !- Sensible Fraction Schedule Name
+ {51bb7594-16a3-47b7-a4b3-b7caad5020e9}; !- Latent Fraction Schedule Name
+
+OS:Schedule:Ruleset,
+ {bc62fd2a-3bbb-4373-8518-f473eef07fcb}, !- Handle
+ Fraction Sensible - 0.2, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {63963257-36ce-4910-9279-82fb6bd91b80}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {63963257-36ce-4910-9279-82fb6bd91b80}, !- Handle
+ Fraction Sensible - 0.2 Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0.2; !- Value Until Time 1
+
+OS:Schedule:Ruleset,
+ {51bb7594-16a3-47b7-a4b3-b7caad5020e9}, !- Handle
+ Fraction Latent - 0.05, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ {4b36ca18-95c8-42ee-8186-8fc40f4cd951}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {4b36ca18-95c8-42ee-8186-8fc40f4cd951}, !- Handle
+ Fraction Latent - 0.05 Default, !- Name
+ {4116f30f-50ac-415b-992a-95c39519e1d3}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0.05; !- Value Until Time 1
+
+OS:Schedule:Ruleset,
+ {93d0b10a-3452-4e29-af37-806e3b606820}, !- Handle
+ Mixed Water At Faucet Temp - 140F, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ {2a824c39-7677-4760-9fbe-5342521810f5}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {2a824c39-7677-4760-9fbe-5342521810f5}, !- Handle
+ Mixed Water At Faucet Temp - 140F Default, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 60.0000000000001; !- Value Until Time 1
+
+OS:ScheduleTypeLimits,
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Handle
+ Temperature, !- Name
+ , !- Lower Limit Value
+ , !- Upper Limit Value
+ Continuous, !- Numeric Type
+ Temperature; !- Unit Type
+
+OS:WaterUse:Equipment,
+ {c725894c-43c8-4e18-8c6e-be29b6116f59}, !- Handle
+ Office WholeBuilding - Sm Office - ComStock DOE Ref Pre-1980 Service Water Use 0.03gpm at 140F, !- Name
+ {f4953159-aca5-4b84-87b1-8060db0f9b83}, !- Water Use Equipment Definition Name
+ , !- Space Name
+ {523faf97-0fb7-4d65-97fd-12101be7312e}; !- Flow Rate Fraction Schedule Name
+
+OS:PlantLoop,
+ {b2fc16c1-a235-4b34-a039-af6b11f5e8c6}, !- Handle
+ Office Shared Service Water Loop, !- Name
+ , !- Fluid Type
+ 0, !- Glycol Concentration
+ , !- User Defined Fluid Type
+ , !- Plant Equipment Operation Heating Load
+ , !- Plant Equipment Operation Cooling Load
+ , !- Primary Plant Equipment Operation Scheme
+ {fecd9509-d91a-4124-b784-586c52c4bdcd}, !- Loop Temperature Setpoint Node Name
+ 60, !- Maximum Loop Temperature {C}
+ 10, !- Minimum Loop Temperature {C}
+ , !- Maximum Loop Flow Rate {m3/s}
+ , !- Minimum Loop Flow Rate {m3/s}
+ Autocalculate, !- Plant Loop Volume {m3}
+ {4f831868-1021-4f1c-8a57-c78dd6d8a1a8}, !- Plant Side Inlet Node Name
+ {f68157bd-7eb1-45fa-bcd5-98033d40a97f}, !- Plant Side Outlet Node Name
+ , !- Plant Side Branch List Name
+ {43b69c29-2170-4485-b65d-52246a18e967}, !- Demand Side Inlet Node Name
+ {579c4e8c-224f-4d15-a36c-c65e13851ba6}, !- Demand Side Outlet Node Name
+ , !- Demand Side Branch List Name
+ , !- Demand Side Connector List Name
+ Optimal, !- Load Distribution Scheme
+ {2ffdf10e-276f-48f0-9a83-67740d110aa1}, !- Availability Manager List Name
+ , !- Plant Loop Demand Calculation Scheme
+ , !- Common Pipe Simulation
+ , !- Pressure Simulation Type
+ , !- Plant Equipment Operation Heating Load Schedule
+ , !- Plant Equipment Operation Cooling Load Schedule
+ , !- Primary Plant Equipment Operation Scheme Schedule
+ , !- Component Setpoint Operation Scheme Schedule
+ {952fd4d9-38dd-487d-9938-229aab061697}, !- Demand Mixer Name
+ {103d3b54-f5d9-42a5-be01-77d1d497b2d8}, !- Demand Splitter Name
+ {befedf78-7c36-4283-af63-932c0b97e90d}, !- Supply Mixer Name
+ {200e8590-019d-4628-8e44-81ffcb3fdf13}; !- Supply Splitter Name
+
+OS:Node,
+ {462fae8b-d3ea-42a4-bdf8-0ca21fcef66c}, !- Handle
+ Office Shared Service Water Loop Supply Inlet Node, !- Name
+ {4f831868-1021-4f1c-8a57-c78dd6d8a1a8}, !- Inlet Port
+ {4d41a383-53e1-4908-8207-9f091d605001}; !- Outlet Port
+
+OS:Node,
+ {fecd9509-d91a-4124-b784-586c52c4bdcd}, !- Handle
+ Office Shared Service Water Loop Supply Outlet Node, !- Name
+ {a22fe4d6-08e5-4608-87d9-dcf12ba2696f}, !- Inlet Port
+ {f68157bd-7eb1-45fa-bcd5-98033d40a97f}; !- Outlet Port
+
+OS:Node,
+ {184fb0f1-0eaa-4ad2-aadc-5738b8d519c9}, !- Handle
+ 40gal NaturalGas Water Heater - 2kBtu/hr Supply Inlet Water Node, !- Name
+ {f285312f-bff7-424a-bfc8-81d32a0a44fc}, !- Inlet Port
+ {b733bf69-b2e1-438b-90ee-7c5635859804}; !- Outlet Port
+
+OS:Connector:Mixer,
+ {befedf78-7c36-4283-af63-932c0b97e90d}, !- Handle
+ Connector Mixer 1, !- Name
+ {9106a057-5ea0-4a86-9cc9-c677355b3ee1}, !- Outlet Branch Name
+ {f6e27a7f-bd54-4def-a90e-94c68c1f3250}, !- Inlet Branch Name 1
+ {f9522144-3ab3-4204-8a6c-e731d0ae24fd}; !- Inlet Branch Name 2
+
+OS:Connector:Splitter,
+ {200e8590-019d-4628-8e44-81ffcb3fdf13}, !- Handle
+ Connector Splitter 1, !- Name
+ {29e279e1-1580-46ab-82db-5ef8c4e44826}, !- Inlet Branch Name
+ {f285312f-bff7-424a-bfc8-81d32a0a44fc}, !- Outlet Branch Name 1
+ {21787523-0ca3-456e-9e69-8952594b23c6}; !- Outlet Branch Name 2
+
+OS:Connection,
+ {4f831868-1021-4f1c-8a57-c78dd6d8a1a8}, !- Handle
+ {b2fc16c1-a235-4b34-a039-af6b11f5e8c6}, !- Source Object
+ 14, !- Outlet Port
+ {462fae8b-d3ea-42a4-bdf8-0ca21fcef66c}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {f285312f-bff7-424a-bfc8-81d32a0a44fc}, !- Handle
+ {200e8590-019d-4628-8e44-81ffcb3fdf13}, !- Source Object
+ 3, !- Outlet Port
+ {184fb0f1-0eaa-4ad2-aadc-5738b8d519c9}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {f68157bd-7eb1-45fa-bcd5-98033d40a97f}, !- Handle
+ {fecd9509-d91a-4124-b784-586c52c4bdcd}, !- Source Object
+ 3, !- Outlet Port
+ {b2fc16c1-a235-4b34-a039-af6b11f5e8c6}, !- Target Object
+ 15; !- Inlet Port
+
+OS:Node,
+ {363c7f37-59a2-4739-a16d-f9045678ac1e}, !- Handle
+ Office Shared Service Water Loop Demand Inlet Node, !- Name
+ {43b69c29-2170-4485-b65d-52246a18e967}, !- Inlet Port
+ {0e53c890-b409-4bdb-80f8-0a5579515c46}; !- Outlet Port
+
+OS:Node,
+ {03ee9b4f-b85a-4ebb-87ab-f9a2b9a32780}, !- Handle
+ Office Shared Service Water Loop Demand Outlet Node, !- Name
+ {975425ce-6039-47ce-aeff-d3dbf52f0072}, !- Inlet Port
+ {579c4e8c-224f-4d15-a36c-c65e13851ba6}; !- Outlet Port
+
+OS:Node,
+ {0a0ce30d-119f-4a46-8db4-df005e43b2cf}, !- Handle
+ Pipe Adiabatic 2 Inlet Water Node, !- Name
+ {ed371dd8-43b4-464f-acd9-0f52c6460737}, !- Inlet Port
+ {2bc9e7eb-2964-4ca8-b484-574bc266e667}; !- Outlet Port
+
+OS:Connector:Mixer,
+ {952fd4d9-38dd-487d-9938-229aab061697}, !- Handle
+ Connector Mixer 2, !- Name
+ {98b72455-6a2d-46f1-998b-d29d84d38b70}, !- Outlet Branch Name
+ {2b67391b-0cd5-4790-bf85-d719a8b84f98}, !- Inlet Branch Name 1
+ {644dfd63-cc47-4711-955e-f2ee361d3abb}; !- Inlet Branch Name 2
+
+OS:Connector:Splitter,
+ {103d3b54-f5d9-42a5-be01-77d1d497b2d8}, !- Handle
+ Connector Splitter 2, !- Name
+ {a6a3312b-19c3-4062-9175-d3e7fe82cfd0}, !- Inlet Branch Name
+ {ed371dd8-43b4-464f-acd9-0f52c6460737}, !- Outlet Branch Name 1
+ {ed7d7437-8144-4307-bdf3-61ae900e39f4}; !- Outlet Branch Name 2
+
+OS:Connection,
+ {43b69c29-2170-4485-b65d-52246a18e967}, !- Handle
+ {b2fc16c1-a235-4b34-a039-af6b11f5e8c6}, !- Source Object
+ 17, !- Outlet Port
+ {363c7f37-59a2-4739-a16d-f9045678ac1e}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {ed371dd8-43b4-464f-acd9-0f52c6460737}, !- Handle
+ {103d3b54-f5d9-42a5-be01-77d1d497b2d8}, !- Source Object
+ 3, !- Outlet Port
+ {0a0ce30d-119f-4a46-8db4-df005e43b2cf}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {579c4e8c-224f-4d15-a36c-c65e13851ba6}, !- Handle
+ {03ee9b4f-b85a-4ebb-87ab-f9a2b9a32780}, !- Source Object
+ 3, !- Outlet Port
+ {b2fc16c1-a235-4b34-a039-af6b11f5e8c6}, !- Target Object
+ 18; !- Inlet Port
+
+OS:Sizing:Plant,
+ {3447eed2-08b4-443c-bc1d-6c4e39f40973}, !- Handle
+ {b2fc16c1-a235-4b34-a039-af6b11f5e8c6}, !- Plant or Condenser Loop Name
+ Heating, !- Loop Type
+ 60.0000000000001, !- Design Loop Exit Temperature {C}
+ 5, !- Loop Design Temperature Difference {deltaC}
+ NonCoincident, !- Sizing Option
+ 1, !- Zone Timesteps in Averaging Window
+ None; !- Coincident Sizing Factor Mode
+
+OS:AvailabilityManagerAssignmentList,
+ {2ffdf10e-276f-48f0-9a83-67740d110aa1}, !- Handle
+ Plant Loop 1 AvailabilityManagerAssignmentList; !- Name
+
+OS:ScheduleTypeLimits,
+ {57a2158e-c35b-4f99-b9bb-e48fe83077d1}, !- Handle
+ Temperature Schedule Type Limits, !- Name
+ 0, !- Lower Limit Value
+ 100, !- Upper Limit Value
+ Continuous, !- Numeric Type
+ Temperature; !- Unit Type
+
+OS:Schedule:Ruleset,
+ {9a5de9f0-87df-4cb0-b1f3-e317733d63b1}, !- Handle
+ Service Water Loop Temp - 140F, !- Name
+ {57a2158e-c35b-4f99-b9bb-e48fe83077d1}, !- Schedule Type Limits Name
+ {c157c9e4-f2cf-47b7-8be7-5e9aac62506d}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {c157c9e4-f2cf-47b7-8be7-5e9aac62506d}, !- Handle
+ Service Water Loop Temp - 140F Default, !- Name
+ {57a2158e-c35b-4f99-b9bb-e48fe83077d1}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 60.0000000000001; !- Value Until Time 1
+
+OS:SetpointManager:Scheduled,
+ {11c24962-60ed-48a9-9c60-51a2b75adae3}, !- Handle
+ Service hot water setpoint manager, !- Name
+ Temperature, !- Control Variable
+ {9a5de9f0-87df-4cb0-b1f3-e317733d63b1}, !- Schedule Name
+ {fecd9509-d91a-4124-b784-586c52c4bdcd}; !- Setpoint Node or NodeList Name
+
+OS:Pump:ConstantSpeed,
+ {ba213f8e-66e7-41e7-b2f2-50a81f79a3be}, !- Handle
+ Office Shared Service Water Loop Circulator Pump, !- Name
+ {4d41a383-53e1-4908-8207-9f091d605001}, !- Inlet Node Name
+ {2629b831-9dac-4043-bf30-98b30eea2408}, !- Outlet Node Name
+ autosize, !- Rated Flow Rate {m3/s}
+ 29890.6692, !- Rated Pump Head {Pa}
+ autosize, !- Rated Power Consumption {W}
+ 0.825, !- Motor Efficiency
+ 0, !- Fraction of Motor Inefficiencies to Fluid Stream
+ Intermittent, !- Pump Control Type
+ , !- Pump Flow Rate Schedule
+ , !- Pump Curve
+ , !- Impeller Diameter {m}
+ , !- Rotational Speed {rev/min}
+ , !- Zone
+ , !- Skin Loss Radiative Fraction
+ PowerPerFlowPerPressure, !- Design Power Sizing Method
+ 348701.1, !- Design Electric Power per Unit Flow Rate {W/(m3/s)}
+ 1.282051282, !- Design Shaft Power per Unit Flow Rate per Unit Head {W-s/m3-Pa}
+ General; !- End-Use Subcategory
+
+OS:Node,
+ {ecececdb-5c30-4713-b39e-824cc8786701}, !- Handle
+ Office Shared Service Water Loop Circulator Pump Outlet Water Node, !- Name
+ {2629b831-9dac-4043-bf30-98b30eea2408}, !- Inlet Port
+ {29e279e1-1580-46ab-82db-5ef8c4e44826}; !- Outlet Port
+
+OS:Connection,
+ {4d41a383-53e1-4908-8207-9f091d605001}, !- Handle
+ {462fae8b-d3ea-42a4-bdf8-0ca21fcef66c}, !- Source Object
+ 3, !- Outlet Port
+ {ba213f8e-66e7-41e7-b2f2-50a81f79a3be}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {2629b831-9dac-4043-bf30-98b30eea2408}, !- Handle
+ {ba213f8e-66e7-41e7-b2f2-50a81f79a3be}, !- Source Object
+ 3, !- Outlet Port
+ {ecececdb-5c30-4713-b39e-824cc8786701}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {29e279e1-1580-46ab-82db-5ef8c4e44826}, !- Handle
+ {ecececdb-5c30-4713-b39e-824cc8786701}, !- Source Object
+ 3, !- Outlet Port
+ {200e8590-019d-4628-8e44-81ffcb3fdf13}, !- Target Object
+ 2; !- Inlet Port
+
+OS:WaterHeater:Mixed,
+ {6027fc8c-782d-473f-8bee-4a2ca63296ff}, !- Handle
+ 40gal NaturalGas Water Heater - 2kBtu/hr 0.78 Therm Eff, !- Name
+ 0.151416471358794, !- Tank Volume {m3}
+ {9a5de9f0-87df-4cb0-b1f3-e317733d63b1}, !- Setpoint Temperature Schedule Name
+ 2, !- Deadband Temperature Difference {deltaC}
+ 60.0000000000001, !- Maximum Temperature Limit {C}
+ Cycle, !- Heater Control Type
+ 587.260732164593, !- Heater Maximum Capacity {W}
+ , !- Heater Minimum Capacity {W}
+ , !- Heater Ignition Minimum Flow Rate {m3/s}
+ , !- Heater Ignition Delay {s}
+ NaturalGas, !- Heater Fuel Type
+ 0.78, !- Heater Thermal Efficiency
+ , !- Part Load Factor Curve Name
+ 0, !- Off Cycle Parasitic Fuel Consumption Rate {W}
+ NaturalGas, !- Off Cycle Parasitic Fuel Type
+ 0, !- Off Cycle Parasitic Heat Fraction to Tank
+ 0, !- On Cycle Parasitic Fuel Consumption Rate {W}
+ NaturalGas, !- On Cycle Parasitic Fuel Type
+ 0, !- On Cycle Parasitic Heat Fraction to Tank
+ Schedule, !- Ambient Temperature Indicator
+ {95213ca4-cda2-4cf1-80d3-90028e780848}, !- Ambient Temperature Schedule Name
+ , !- Ambient Temperature Thermal Zone Name
+ , !- Ambient Temperature Outdoor Air Node Name
+ 5.9979925221447, !- Off Cycle Loss Coefficient to Ambient Temperature {W/K}
+ , !- Off Cycle Loss Fraction to Thermal Zone
+ 5.9979925221447, !- On Cycle Loss Coefficient to Ambient Temperature {W/K}
+ , !- On Cycle Loss Fraction to Thermal Zone
+ , !- Peak Use Flow Rate {m3/s}
+ , !- Use Flow Rate Fraction Schedule Name
+ , !- Cold Water Supply Temperature Schedule Name
+ {b733bf69-b2e1-438b-90ee-7c5635859804}, !- Use Side Inlet Node Name
+ {40a97a96-d6fd-4404-8452-212f5d1fc2d6}, !- Use Side Outlet Node Name
+ 1, !- Use Side Effectiveness
+ , !- Source Side Inlet Node Name
+ , !- Source Side Outlet Node Name
+ 1, !- Source Side Effectiveness
+ autosize, !- Use Side Design Flow Rate {m3/s}
+ autosize, !- Source Side Design Flow Rate {m3/s}
+ 1.5, !- Indirect Water Heating Recovery Time {hr}
+ IndirectHeatPrimarySetpoint, !- Source Side Flow Control Mode
+ , !- Indirect Alternate Setpoint Temperature Schedule Name
+ General; !- End-Use Subcategory
+
+OS:WaterHeater:Sizing,
+ {3f9dd403-539a-467b-badf-695b893e7d3f}, !- Handle
+ {6027fc8c-782d-473f-8bee-4a2ca63296ff}, !- WaterHeater Name
+ PeakDraw, !- Design Mode
+ 0.538503, !- Time Storage Can Meet Peak Draw {hr}
+ 0, !- Time for Tank Recovery {hr}
+ 1; !- Nominal Tank Volume for Autosizing Plant Connections {m3}
+
+OS:ScheduleTypeLimits,
+ {800070da-a319-4db5-aadb-d0af195365e6}, !- Handle
+ Temperature Schedule Type Limits 1, !- Name
+ 0, !- Lower Limit Value
+ 100, !- Upper Limit Value
+ Continuous, !- Numeric Type
+ Temperature; !- Unit Type
+
+OS:Schedule:Ruleset,
+ {95213ca4-cda2-4cf1-80d3-90028e780848}, !- Handle
+ Water Heater Ambient Temp Schedule 71.6F, !- Name
+ {800070da-a319-4db5-aadb-d0af195365e6}, !- Schedule Type Limits Name
+ {8c783e41-98f9-42c5-9082-1cdc9e2f5808}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {8c783e41-98f9-42c5-9082-1cdc9e2f5808}, !- Handle
+ Water Heater Ambient Temp Schedule 71.6F Default, !- Name
+ {800070da-a319-4db5-aadb-d0af195365e6}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 22.0000000000001; !- Value Until Time 1
+
+OS:Node,
+ {ad155f27-73b4-42b8-9d74-57605394da70}, !- Handle
+ 40gal NaturalGas Water Heater - 2kBtu/hr Supply Outlet Water Node, !- Name
+ {40a97a96-d6fd-4404-8452-212f5d1fc2d6}, !- Inlet Port
+ {f6e27a7f-bd54-4def-a90e-94c68c1f3250}; !- Outlet Port
+
+OS:Connection,
+ {b733bf69-b2e1-438b-90ee-7c5635859804}, !- Handle
+ {184fb0f1-0eaa-4ad2-aadc-5738b8d519c9}, !- Source Object
+ 3, !- Outlet Port
+ {6027fc8c-782d-473f-8bee-4a2ca63296ff}, !- Target Object
+ 31; !- Inlet Port
+
+OS:Connection,
+ {40a97a96-d6fd-4404-8452-212f5d1fc2d6}, !- Handle
+ {6027fc8c-782d-473f-8bee-4a2ca63296ff}, !- Source Object
+ 32, !- Outlet Port
+ {ad155f27-73b4-42b8-9d74-57605394da70}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {f6e27a7f-bd54-4def-a90e-94c68c1f3250}, !- Handle
+ {ad155f27-73b4-42b8-9d74-57605394da70}, !- Source Object
+ 3, !- Outlet Port
+ {befedf78-7c36-4283-af63-932c0b97e90d}, !- Target Object
+ 3; !- Inlet Port
+
+OS:AdditionalProperties,
+ {63ef205e-e6da-441c-8581-c0de1a2dfca8}, !- Handle
+ {6027fc8c-782d-473f-8bee-4a2ca63296ff}; !- Object Name
+
+OS:Schedule:Ruleset,
+ {459839da-8fcf-46bc-a4a0-12d52de11e5d}, !- Handle
+ Office Shared Service Water Loop Piping Air Temp - 70F, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ {35c6a199-a032-4591-86d5-2186abf4496d}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {35c6a199-a032-4591-86d5-2186abf4496d}, !- Handle
+ Office Shared Service Water Loop Piping Air Temp - 70F Default, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 21.1111; !- Value Until Time 1
+
+OS:Schedule:Ruleset,
+ {6a1ec8f4-75fa-412c-9e5c-9b19abf08078}, !- Handle
+ Office Shared Service Water Loop Piping Air Velocity - 0.67mph, !- Name
+ {fc59e417-dbc3-4027-9396-2c2f888b76b3}, !- Schedule Type Limits Name
+ {699ac2bb-860a-4edb-bf3c-9099f4473cdf}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {699ac2bb-860a-4edb-bf3c-9099f4473cdf}, !- Handle
+ Office Shared Service Water Loop Piping Air Velocity - 0.67mph Default, !- Name
+ {fc59e417-dbc3-4027-9396-2c2f888b76b3}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0.3; !- Value Until Time 1
+
+OS:ScheduleTypeLimits,
+ {fc59e417-dbc3-4027-9396-2c2f888b76b3}, !- Handle
+ Dimensionless, !- Name
+ 0, !- Lower Limit Value
+ 1000, !- Upper Limit Value
+ Continuous, !- Numeric Type
+ Dimensionless; !- Unit Type
+
+OS:Material,
+ {654db37a-9f7b-477a-a04e-0e724d82c11a}, !- Handle
+ Copper pipe 0.75in type L, !- Name
+ Smooth, !- Roughness
+ 0.001143, !- Thickness {m}
+ 386, !- Conductivity {W/m-K}
+ 8906.26563592184, !- Density {kg/m3}
+ 385.1856, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Construction,
+ {b867469e-c77d-44f6-9002-a0d91c146056}, !- Handle
+ Copper pipe 0.75in type L with 0.5in fiberglass batt, !- Name
+ , !- Surface Rendering Name
+ {baed53d3-a22d-4016-be2e-3aef134c0014}, !- Layer 1
+ {654db37a-9f7b-477a-a04e-0e724d82c11a}; !- Layer 2
+
+OS:Material,
+ {baed53d3-a22d-4016-be2e-3aef134c0014}, !- Handle
+ Fiberglass batt 0.5in, !- Name
+ Smooth, !- Roughness
+ 0.0127, !- Thickness {m}
+ 0.06634482887757, !- Conductivity {W/m-K}
+ 11.2129243617721, !- Density {kg/m3}
+ 837.36, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Pipe:Indoor,
+ {aa77c20c-18cf-4ddb-8773-1c72e1ce9285}, !- Handle
+ Office Shared Service Water Loop Pipe 118.32159566199246ft, !- Name
+ {b867469e-c77d-44f6-9002-a0d91c146056}, !- Construction
+ {0e53c890-b409-4bdb-80f8-0a5579515c46}, !- Fluid Inlet Node
+ {aaa971fd-6b59-4db6-8491-5ad3dd537776}, !- Fluid Outlet Node
+ Schedule, !- Environment Type
+ , !- Ambient Temperature Zone
+ {459839da-8fcf-46bc-a4a0-12d52de11e5d}, !- Ambient Temperature Schedule
+ {6a1ec8f4-75fa-412c-9e5c-9b19abf08078}, !- Ambient Air Velocity Schedule
+ 0.019939, !- Pipe Inside Diameter {m}
+ 36.0644223577753; !- Pipe Length {m}
+
+OS:Node,
+ {b59daddb-2a4c-4bbb-8b61-bf4f7b086c5a}, !- Handle
+ Office Shared Service Water Loop Pipe 118.32159566199246ft Outlet Water Node, !- Name
+ {aaa971fd-6b59-4db6-8491-5ad3dd537776}, !- Inlet Port
+ {a6a3312b-19c3-4062-9175-d3e7fe82cfd0}; !- Outlet Port
+
+OS:Connection,
+ {0e53c890-b409-4bdb-80f8-0a5579515c46}, !- Handle
+ {363c7f37-59a2-4739-a16d-f9045678ac1e}, !- Source Object
+ 3, !- Outlet Port
+ {aa77c20c-18cf-4ddb-8773-1c72e1ce9285}, !- Target Object
+ 3; !- Inlet Port
+
+OS:Connection,
+ {aaa971fd-6b59-4db6-8491-5ad3dd537776}, !- Handle
+ {aa77c20c-18cf-4ddb-8773-1c72e1ce9285}, !- Source Object
+ 4, !- Outlet Port
+ {b59daddb-2a4c-4bbb-8b61-bf4f7b086c5a}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {a6a3312b-19c3-4062-9175-d3e7fe82cfd0}, !- Handle
+ {b59daddb-2a4c-4bbb-8b61-bf4f7b086c5a}, !- Source Object
+ 3, !- Outlet Port
+ {103d3b54-f5d9-42a5-be01-77d1d497b2d8}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {f14f08ff-f5f3-4305-abbf-221d2f90d39f}, !- Handle
+ Pipe Adiabatic 1, !- Name
+ {d3063b71-d843-4f7b-8b33-c4bd2c2e0183}, !- Inlet Node Name
+ {fb3f9b0f-e30e-4fcf-819b-80a7fdb37108}; !- Outlet Node Name
+
+OS:Node,
+ {e6913113-f8c3-40eb-a599-c4946a981e49}, !- Handle
+ Pipe Adiabatic 1 Inlet Water Node, !- Name
+ {21787523-0ca3-456e-9e69-8952594b23c6}, !- Inlet Port
+ {d3063b71-d843-4f7b-8b33-c4bd2c2e0183}; !- Outlet Port
+
+OS:Connection,
+ {21787523-0ca3-456e-9e69-8952594b23c6}, !- Handle
+ {200e8590-019d-4628-8e44-81ffcb3fdf13}, !- Source Object
+ 4, !- Outlet Port
+ {e6913113-f8c3-40eb-a599-c4946a981e49}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Node,
+ {5bd6385b-55ae-4564-87f0-84a8151833ac}, !- Handle
+ Pipe Adiabatic 1 Outlet Water Node, !- Name
+ {fb3f9b0f-e30e-4fcf-819b-80a7fdb37108}, !- Inlet Port
+ {f9522144-3ab3-4204-8a6c-e731d0ae24fd}; !- Outlet Port
+
+OS:Connection,
+ {d3063b71-d843-4f7b-8b33-c4bd2c2e0183}, !- Handle
+ {e6913113-f8c3-40eb-a599-c4946a981e49}, !- Source Object
+ 3, !- Outlet Port
+ {f14f08ff-f5f3-4305-abbf-221d2f90d39f}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {fb3f9b0f-e30e-4fcf-819b-80a7fdb37108}, !- Handle
+ {f14f08ff-f5f3-4305-abbf-221d2f90d39f}, !- Source Object
+ 3, !- Outlet Port
+ {5bd6385b-55ae-4564-87f0-84a8151833ac}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {f9522144-3ab3-4204-8a6c-e731d0ae24fd}, !- Handle
+ {5bd6385b-55ae-4564-87f0-84a8151833ac}, !- Source Object
+ 3, !- Outlet Port
+ {befedf78-7c36-4283-af63-932c0b97e90d}, !- Target Object
+ 4; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {1a924f48-8c20-4535-a2e8-00ad2d22a014}, !- Handle
+ Pipe Adiabatic 2, !- Name
+ {2bc9e7eb-2964-4ca8-b484-574bc266e667}, !- Inlet Node Name
+ {6c7114fd-42d7-4175-8601-cb791057d134}; !- Outlet Node Name
+
+OS:Node,
+ {38fb6873-7ebc-4245-9b4f-496782ee2f0b}, !- Handle
+ Pipe Adiabatic 2 Outlet Water Node, !- Name
+ {6c7114fd-42d7-4175-8601-cb791057d134}, !- Inlet Port
+ {2b67391b-0cd5-4790-bf85-d719a8b84f98}; !- Outlet Port
+
+OS:Connection,
+ {2bc9e7eb-2964-4ca8-b484-574bc266e667}, !- Handle
+ {0a0ce30d-119f-4a46-8db4-df005e43b2cf}, !- Source Object
+ 3, !- Outlet Port
+ {1a924f48-8c20-4535-a2e8-00ad2d22a014}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {6c7114fd-42d7-4175-8601-cb791057d134}, !- Handle
+ {1a924f48-8c20-4535-a2e8-00ad2d22a014}, !- Source Object
+ 3, !- Outlet Port
+ {38fb6873-7ebc-4245-9b4f-496782ee2f0b}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {2b67391b-0cd5-4790-bf85-d719a8b84f98}, !- Handle
+ {38fb6873-7ebc-4245-9b4f-496782ee2f0b}, !- Source Object
+ 3, !- Outlet Port
+ {952fd4d9-38dd-487d-9938-229aab061697}, !- Target Object
+ 3; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {27dbb220-98c1-40a2-b01c-23680638619f}, !- Handle
+ Pipe Adiabatic 3, !- Name
+ {43cac368-4a67-496b-98d6-8f8165e84a9c}, !- Inlet Node Name
+ {a22fe4d6-08e5-4608-87d9-dcf12ba2696f}; !- Outlet Node Name
+
+OS:Node,
+ {2f7b9e98-d7da-42a6-bd15-f5b8f524cfe1}, !- Handle
+ Pipe Adiabatic 3 Inlet Water Node, !- Name
+ {9106a057-5ea0-4a86-9cc9-c677355b3ee1}, !- Inlet Port
+ {43cac368-4a67-496b-98d6-8f8165e84a9c}; !- Outlet Port
+
+OS:Connection,
+ {9106a057-5ea0-4a86-9cc9-c677355b3ee1}, !- Handle
+ {befedf78-7c36-4283-af63-932c0b97e90d}, !- Source Object
+ 2, !- Outlet Port
+ {2f7b9e98-d7da-42a6-bd15-f5b8f524cfe1}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {43cac368-4a67-496b-98d6-8f8165e84a9c}, !- Handle
+ {2f7b9e98-d7da-42a6-bd15-f5b8f524cfe1}, !- Source Object
+ 3, !- Outlet Port
+ {27dbb220-98c1-40a2-b01c-23680638619f}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {a22fe4d6-08e5-4608-87d9-dcf12ba2696f}, !- Handle
+ {27dbb220-98c1-40a2-b01c-23680638619f}, !- Source Object
+ 3, !- Outlet Port
+ {fecd9509-d91a-4124-b784-586c52c4bdcd}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {2b0f5fe7-4394-42db-aa3d-276cb085a67b}, !- Handle
+ Pipe Adiabatic 4, !- Name
+ {ce287302-78f2-44ad-b35f-d4be9fc2394f}, !- Inlet Node Name
+ {975425ce-6039-47ce-aeff-d3dbf52f0072}; !- Outlet Node Name
+
+OS:Node,
+ {eaca966c-d909-4065-984b-22bcde021b3d}, !- Handle
+ Pipe Adiabatic 4 Inlet Water Node, !- Name
+ {98b72455-6a2d-46f1-998b-d29d84d38b70}, !- Inlet Port
+ {ce287302-78f2-44ad-b35f-d4be9fc2394f}; !- Outlet Port
+
+OS:Connection,
+ {98b72455-6a2d-46f1-998b-d29d84d38b70}, !- Handle
+ {952fd4d9-38dd-487d-9938-229aab061697}, !- Source Object
+ 2, !- Outlet Port
+ {eaca966c-d909-4065-984b-22bcde021b3d}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {ce287302-78f2-44ad-b35f-d4be9fc2394f}, !- Handle
+ {eaca966c-d909-4065-984b-22bcde021b3d}, !- Source Object
+ 3, !- Outlet Port
+ {2b0f5fe7-4394-42db-aa3d-276cb085a67b}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {975425ce-6039-47ce-aeff-d3dbf52f0072}, !- Handle
+ {2b0f5fe7-4394-42db-aa3d-276cb085a67b}, !- Source Object
+ 3, !- Outlet Port
+ {03ee9b4f-b85a-4ebb-87ab-f9a2b9a32780}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Node,
+ {3b47b160-3129-4e43-a8e4-c13dfc5340b3}, !- Handle
+ Office WholeBuilding - Sm Office - ComStock DOE Ref Pre-1980 WUC 0.03gpm at 140F Inlet Water Node, !- Name
+ {ed7d7437-8144-4307-bdf3-61ae900e39f4}, !- Inlet Port
+ {ba34a2b8-da1e-48bc-8ae3-85e40f22c3bf}; !- Outlet Port
+
+OS:Connection,
+ {ed7d7437-8144-4307-bdf3-61ae900e39f4}, !- Handle
+ {103d3b54-f5d9-42a5-be01-77d1d497b2d8}, !- Source Object
+ 4, !- Outlet Port
+ {3b47b160-3129-4e43-a8e4-c13dfc5340b3}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Node,
+ {f37ee088-f6ba-4b8e-9072-c13c014a8363}, !- Handle
+ Office WholeBuilding - Sm Office - ComStock DOE Ref Pre-1980 WUC 0.03gpm at 140F Outlet Water Node, !- Name
+ {b577f331-6c23-4c43-90e4-1c8f443dc10a}, !- Inlet Port
+ {644dfd63-cc47-4711-955e-f2ee361d3abb}; !- Outlet Port
+
+OS:Connection,
+ {ba34a2b8-da1e-48bc-8ae3-85e40f22c3bf}, !- Handle
+ {3b47b160-3129-4e43-a8e4-c13dfc5340b3}, !- Source Object
+ 3, !- Outlet Port
+ {8460a8df-44c6-4da5-99d9-babe3b1b1462}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {b577f331-6c23-4c43-90e4-1c8f443dc10a}, !- Handle
+ {8460a8df-44c6-4da5-99d9-babe3b1b1462}, !- Source Object
+ 3, !- Outlet Port
+ {f37ee088-f6ba-4b8e-9072-c13c014a8363}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {644dfd63-cc47-4711-955e-f2ee361d3abb}, !- Handle
+ {f37ee088-f6ba-4b8e-9072-c13c014a8363}, !- Source Object
+ 3, !- Outlet Port
+ {952fd4d9-38dd-487d-9938-229aab061697}, !- Target Object
+ 4; !- Inlet Port
+
+OS:ThermostatSetpoint:DualSetpoint,
+ {d160b6d2-2526-4711-b52a-ef4f667798ae}, !- Handle
+ Office WholeBuilding - Sm Office - ComStock DOE Ref Pre-1980 Thermostat, !- Name
+ {20e0c264-d0b2-467c-8f76-ac4f703e49ef}, !- Heating Setpoint Temperature Schedule Name
+ {135c98b5-396a-4b9c-acb1-74eb5a7d66cc}; !- Cooling Setpoint Temperature Schedule Name
+
+OS:Schedule:Ruleset,
+ {20e0c264-d0b2-467c-8f76-ac4f703e49ef}, !- Handle
+ Small Office HtgSetp, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ {e8b53972-7e41-4d90-abe5-99fdd819fc0a}, !- Default Day Schedule Name
+ {dfe6d929-d8d7-4a7c-9ebc-8737a17afac1}, !- Summer Design Day Schedule Name
+ {668403f9-ed75-46ea-ac85-c74d44e08f9f}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {e8b53972-7e41-4d90-abe5-99fdd819fc0a}, !- Handle
+ Small Office HtgSetp Default, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 15.6, !- Value Until Time 1
+ 22, !- Hour 2
+ 0, !- Minute 2
+ 21, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 15.6; !- Value Until Time 3
+
+OS:Schedule:Rule,
+ {b27fc804-68c9-4df8-a517-5bf26d570ef8}, !- Handle
+ Schedule Rule 13, !- Name
+ {20e0c264-d0b2-467c-8f76-ac4f703e49ef}, !- Schedule Ruleset Name
+ 1, !- Rule Order
+ {5d091ad1-7ddc-40d5-aea1-4d8466674ce7}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ Yes, !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {5d091ad1-7ddc-40d5-aea1-4d8466674ce7}, !- Handle
+ Small Office HtgSetp Sat Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 15.6, !- Value Until Time 1
+ 18, !- Hour 2
+ 0, !- Minute 2
+ 21, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 15.6; !- Value Until Time 3
+
+OS:Schedule:Day,
+ {dfe6d929-d8d7-4a7c-9ebc-8737a17afac1}, !- Handle
+ Small Office HtgSetp Summer Design Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 15.6; !- Value Until Time 1
+
+OS:Schedule:Rule,
+ {85d30584-ceae-4eaa-a32f-22ba9bdee9e7}, !- Handle
+ Schedule Rule 14, !- Name
+ {20e0c264-d0b2-467c-8f76-ac4f703e49ef}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {e7357781-46cd-4339-a69f-bb897e89ec6c}, !- Day Schedule Name
+ Yes, !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {e7357781-46cd-4339-a69f-bb897e89ec6c}, !- Handle
+ Small Office HtgSetp SmrDsn|Sun Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 15.6; !- Value Until Time 1
+
+OS:Schedule:Day,
+ {668403f9-ed75-46ea-ac85-c74d44e08f9f}, !- Handle
+ Small Office HtgSetp Winter Design Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 21; !- Value Until Time 1
+
+OS:Schedule:Ruleset,
+ {135c98b5-396a-4b9c-acb1-74eb5a7d66cc}, !- Handle
+ Small Office ClgSetp, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ {e4f4d214-46bf-4f35-8117-655c978cbaea}, !- Default Day Schedule Name
+ {554945e3-ac0b-4ea1-ab7e-c4bfd2f38a15}, !- Summer Design Day Schedule Name
+ {d3e8ea1a-dc74-419b-af37-65a29a4d7f5b}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {e4f4d214-46bf-4f35-8117-655c978cbaea}, !- Handle
+ Small Office ClgSetp Default, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 26.7, !- Value Until Time 1
+ 22, !- Hour 2
+ 0, !- Minute 2
+ 24, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 26.7; !- Value Until Time 3
+
+OS:Schedule:Day,
+ {554945e3-ac0b-4ea1-ab7e-c4bfd2f38a15}, !- Handle
+ Small Office ClgSetp Summer Design Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 26.7, !- Value Until Time 1
+ 22, !- Hour 2
+ 0, !- Minute 2
+ 24, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 26.7; !- Value Until Time 3
+
+OS:Schedule:Rule,
+ {7ee18d73-6d12-4f3a-bb47-73f51fc3d177}, !- Handle
+ Schedule Rule 15, !- Name
+ {135c98b5-396a-4b9c-acb1-74eb5a7d66cc}, !- Schedule Ruleset Name
+ 1, !- Rule Order
+ {e433b27c-b062-4dff-ba91-b3f049eaf90c}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ Yes, !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {e433b27c-b062-4dff-ba91-b3f049eaf90c}, !- Handle
+ Small Office ClgSetp Sat Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 6, !- Hour 1
+ 0, !- Minute 1
+ 26.7, !- Value Until Time 1
+ 18, !- Hour 2
+ 0, !- Minute 2
+ 24, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 26.7; !- Value Until Time 3
+
+OS:Schedule:Day,
+ {d3e8ea1a-dc74-419b-af37-65a29a4d7f5b}, !- Handle
+ Small Office ClgSetp Winter Design Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 26.7; !- Value Until Time 1
+
+OS:Schedule:Rule,
+ {1434a822-5ff3-4ca8-8091-dca5f467e7b5}, !- Handle
+ Schedule Rule 16, !- Name
+ {135c98b5-396a-4b9c-acb1-74eb5a7d66cc}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {ed0322ed-b433-4a3a-9787-b40f9981082f}, !- Day Schedule Name
+ Yes, !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 1, !- Start Day
+ 12, !- End Month
+ 31; !- End Day
+
+OS:Schedule:Day,
+ {ed0322ed-b433-4a3a-9787-b40f9981082f}, !- Handle
+ Small Office ClgSetp WntrDsn|Sun Day, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ No, !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 26.7; !- Value Until Time 1
+
+OS:Material,
+ {bc3fd780-2282-436d-9581-f5207bda8949}, !- Handle
+ Std Wood 6inch, !- Name
+ MediumSmooth, !- Roughness
+ 0.15, !- Thickness {m}
+ 0.12, !- Conductivity {W/m-K}
+ 540, !- Density {kg/m3}
+ 1210, !- Specific Heat {J/kg-K}
+ 0.9, !- Thermal Absorptance
+ 0.7, !- Solar Absorptance
+ 0.7; !- Visible Absorptance
+
+OS:Construction,
+ {0212f535-8a17-48b3-ba4e-b19d59e6fae1}, !- Handle
+ InteriorFurnishings, !- Name
+ , !- Surface Rendering Name
+ {bc3fd780-2282-436d-9581-f5207bda8949}; !- Layer 1
+
+OS:InternalMass:Definition,
+ {7f0cf5d4-3035-457a-8e04-71a181422fba}, !- Handle
+ Internal Mass Definition 1, !- Name
+ {0212f535-8a17-48b3-ba4e-b19d59e6fae1}, !- Construction Name
+ SurfaceArea/Area, !- Design Level Calculation Method
+ , !- Surface Area {m2}
+ 2, !- Surface Area per Space Floor Area {dimensionless}
+ ; !- Surface Area per Person {m2/person}
+
+OS:InternalMass,
+ {442763f6-34e7-442b-b0ef-3880be8b3c5d}, !- Handle
+ Office WholeBuilding - Sm Office - Story ground Mass, !- Name
+ {7f0cf5d4-3035-457a-8e04-71a181422fba}, !- Internal Mass Definition Name
+ {c11f5d71-ac1c-4b14-bd6c-eda5e056e896}, !- Space or SpaceType Name
+ 1; !- Multiplier
+
+OS:PlantLoop,
+ {01bdf77e-7fea-492d-becd-5e75c671355b}, !- Handle
+ Hot Water Loop, !- Name
+ Water, !- Fluid Type
+ 0, !- Glycol Concentration
+ , !- User Defined Fluid Type
+ , !- Plant Equipment Operation Heating Load
+ , !- Plant Equipment Operation Cooling Load
+ , !- Primary Plant Equipment Operation Scheme
+ {9458db6b-be1c-4f23-aff6-8e78ba354999}, !- Loop Temperature Setpoint Node Name
+ , !- Maximum Loop Temperature {C}
+ 10, !- Minimum Loop Temperature {C}
+ , !- Maximum Loop Flow Rate {m3/s}
+ , !- Minimum Loop Flow Rate {m3/s}
+ Autocalculate, !- Plant Loop Volume {m3}
+ {f9284a83-cbe3-4984-aec8-b634b24681ff}, !- Plant Side Inlet Node Name
+ {3b12bcbd-bf3d-4b98-871a-589beae6b637}, !- Plant Side Outlet Node Name
+ , !- Plant Side Branch List Name
+ {b1ba9b68-8546-42cf-8e5b-3132680a6520}, !- Demand Side Inlet Node Name
+ {a4afc43b-cef4-4991-8987-9538b140a59b}, !- Demand Side Outlet Node Name
+ , !- Demand Side Branch List Name
+ , !- Demand Side Connector List Name
+ Optimal, !- Load Distribution Scheme
+ {e4abecaf-8ff5-4d2f-bce2-596f28e7f59a}, !- Availability Manager List Name
+ , !- Plant Loop Demand Calculation Scheme
+ , !- Common Pipe Simulation
+ , !- Pressure Simulation Type
+ , !- Plant Equipment Operation Heating Load Schedule
+ , !- Plant Equipment Operation Cooling Load Schedule
+ , !- Primary Plant Equipment Operation Scheme Schedule
+ , !- Component Setpoint Operation Scheme Schedule
+ {f875a8c5-6ca6-4019-aa0e-98d692342249}, !- Demand Mixer Name
+ {5c995fb9-d20f-4c54-b919-8dcc7d08738b}, !- Demand Splitter Name
+ {f6d0575b-f55b-4e12-bb59-f58ac27d5e78}, !- Supply Mixer Name
+ {ee51f920-7a9a-4734-9386-4639e650107b}; !- Supply Splitter Name
+
+OS:Node,
+ {5b5b69a7-6289-4993-8110-01085452a4f6}, !- Handle
+ Hot Water Loop Supply Inlet Node, !- Name
+ {f9284a83-cbe3-4984-aec8-b634b24681ff}, !- Inlet Port
+ {8ba7f860-f16c-4da7-87f0-e9de19ab2076}; !- Outlet Port
+
+OS:Node,
+ {9458db6b-be1c-4f23-aff6-8e78ba354999}, !- Handle
+ Hot Water Loop Supply Outlet Node, !- Name
+ {75b8f733-8d98-4041-b8b0-6578ced5566f}, !- Inlet Port
+ {3b12bcbd-bf3d-4b98-871a-589beae6b637}; !- Outlet Port
+
+OS:Node,
+ {d1f0e374-c960-48f6-b4c9-137928ed4097}, !- Handle
+ Boiler Inlet Water Node, !- Name
+ {c4c86193-b4dd-4617-a9f3-89e2343f9f86}, !- Inlet Port
+ {66fdbc5a-7be2-43a7-bfc4-2b1d8eda6437}; !- Outlet Port
+
+OS:Connector:Mixer,
+ {f6d0575b-f55b-4e12-bb59-f58ac27d5e78}, !- Handle
+ Connector Mixer 3, !- Name
+ {c56186a0-7a55-4ec1-8020-c1dfdfae2607}, !- Outlet Branch Name
+ {09a9de5f-6782-4cb6-9c8c-d653d489704a}, !- Inlet Branch Name 1
+ {b719c2e5-d72c-4dd0-8f4c-37d09d17eb85}; !- Inlet Branch Name 2
+
+OS:Connector:Splitter,
+ {ee51f920-7a9a-4734-9386-4639e650107b}, !- Handle
+ Connector Splitter 3, !- Name
+ {9861e72c-4797-454a-baf5-79dd0dab0f8c}, !- Inlet Branch Name
+ {c4c86193-b4dd-4617-a9f3-89e2343f9f86}, !- Outlet Branch Name 1
+ {28c75f65-5b7f-4b4e-af1d-8919da2bec4f}; !- Outlet Branch Name 2
+
+OS:Connection,
+ {f9284a83-cbe3-4984-aec8-b634b24681ff}, !- Handle
+ {01bdf77e-7fea-492d-becd-5e75c671355b}, !- Source Object
+ 14, !- Outlet Port
+ {5b5b69a7-6289-4993-8110-01085452a4f6}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {c4c86193-b4dd-4617-a9f3-89e2343f9f86}, !- Handle
+ {ee51f920-7a9a-4734-9386-4639e650107b}, !- Source Object
+ 3, !- Outlet Port
+ {d1f0e374-c960-48f6-b4c9-137928ed4097}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {3b12bcbd-bf3d-4b98-871a-589beae6b637}, !- Handle
+ {9458db6b-be1c-4f23-aff6-8e78ba354999}, !- Source Object
+ 3, !- Outlet Port
+ {01bdf77e-7fea-492d-becd-5e75c671355b}, !- Target Object
+ 15; !- Inlet Port
+
+OS:Node,
+ {801e7621-21b0-4cba-94c9-30680fdf331d}, !- Handle
+ Hot Water Loop Demand Inlet Node, !- Name
+ {b1ba9b68-8546-42cf-8e5b-3132680a6520}, !- Inlet Port
+ {02f07513-a0b0-4d3e-82b1-7924ed0cf1fb}; !- Outlet Port
+
+OS:Node,
+ {fc97d1d1-d261-42c1-b98f-fa00da9724b2}, !- Handle
+ Hot Water Loop Demand Outlet Node, !- Name
+ {00d8a4b8-3eb1-47a5-823e-cd4e1cf07b81}, !- Inlet Port
+ {a4afc43b-cef4-4991-8987-9538b140a59b}; !- Outlet Port
+
+OS:Node,
+ {9e819282-23d1-49ad-81f0-2b10940683b6}, !- Handle
+ Hot Water Loop Coil Bypass Inlet Water Node, !- Name
+ {7cdfbb77-3412-46dd-beca-665b032aab4f}, !- Inlet Port
+ {84a6b4c4-b948-4d21-8a71-62f7751ee3b6}; !- Outlet Port
+
+OS:Connector:Mixer,
+ {f875a8c5-6ca6-4019-aa0e-98d692342249}, !- Handle
+ Connector Mixer 4, !- Name
+ {4649ce3b-5670-4514-9128-a9b6baa70877}, !- Outlet Branch Name
+ {2cf1aa55-ae45-42ef-9dff-419ee0f71c37}, !- Inlet Branch Name 1
+ {fe7c6ef1-03ab-4ac4-b95e-56d0613ed249}; !- Inlet Branch Name 2
+
+OS:Connector:Splitter,
+ {5c995fb9-d20f-4c54-b919-8dcc7d08738b}, !- Handle
+ Connector Splitter 4, !- Name
+ {fa42050d-f85d-459d-993d-4690f9b8a1d9}, !- Inlet Branch Name
+ {7cdfbb77-3412-46dd-beca-665b032aab4f}, !- Outlet Branch Name 1
+ {eec653c3-d314-4a0b-a11c-23ac10c66d61}; !- Outlet Branch Name 2
+
+OS:Connection,
+ {b1ba9b68-8546-42cf-8e5b-3132680a6520}, !- Handle
+ {01bdf77e-7fea-492d-becd-5e75c671355b}, !- Source Object
+ 17, !- Outlet Port
+ {801e7621-21b0-4cba-94c9-30680fdf331d}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {7cdfbb77-3412-46dd-beca-665b032aab4f}, !- Handle
+ {5c995fb9-d20f-4c54-b919-8dcc7d08738b}, !- Source Object
+ 3, !- Outlet Port
+ {9e819282-23d1-49ad-81f0-2b10940683b6}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {a4afc43b-cef4-4991-8987-9538b140a59b}, !- Handle
+ {fc97d1d1-d261-42c1-b98f-fa00da9724b2}, !- Source Object
+ 3, !- Outlet Port
+ {01bdf77e-7fea-492d-becd-5e75c671355b}, !- Target Object
+ 18; !- Inlet Port
+
+OS:Sizing:Plant,
+ {a08cd745-019d-425f-abde-558a3d32029d}, !- Handle
+ {01bdf77e-7fea-492d-becd-5e75c671355b}, !- Plant or Condenser Loop Name
+ Heating, !- Loop Type
+ 82.2222222222223, !- Design Loop Exit Temperature {C}
+ 11.1111111111111, !- Loop Design Temperature Difference {deltaC}
+ NonCoincident, !- Sizing Option
+ 1, !- Zone Timesteps in Averaging Window
+ None; !- Coincident Sizing Factor Mode
+
+OS:AvailabilityManagerAssignmentList,
+ {e4abecaf-8ff5-4d2f-bce2-596f28e7f59a}, !- Handle
+ Plant Loop 1 AvailabilityManagerAssignmentList 1; !- Name
+
+OS:Schedule:Ruleset,
+ {d8508416-8a72-489b-b065-fee4580845dc}, !- Handle
+ Hot Water Loop Temp - 180F, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ {eb35e972-5270-4f90-8901-4a420234c082}; !- Default Day Schedule Name
+
+OS:Schedule:Day,
+ {eb35e972-5270-4f90-8901-4a420234c082}, !- Handle
+ Hot Water Loop Temp - 180F Default, !- Name
+ {f8566bc6-f7b6-43af-b254-a450fd07a12e}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 82.2222222222223; !- Value Until Time 1
+
+OS:SetpointManager:Scheduled,
+ {411f802d-5a6c-4b75-8c81-14554fec6c77}, !- Handle
+ Hot Water Loop Setpoint Manager, !- Name
+ Temperature, !- Control Variable
+ {d8508416-8a72-489b-b065-fee4580845dc}, !- Schedule Name
+ {9458db6b-be1c-4f23-aff6-8e78ba354999}; !- Setpoint Node or NodeList Name
+
+OS:Pump:VariableSpeed,
+ {c80b729a-23e9-4e44-941a-a46d8fc9bb62}, !- Handle
+ Hot Water Loop Pump, !- Name
+ {8ba7f860-f16c-4da7-87f0-e9de19ab2076}, !- Inlet Node Name
+ {c1a655e3-fada-4333-89bf-ccd06cd1a864}, !- Outlet Node Name
+ , !- Rated Flow Rate {m3/s}
+ 179344.0152, !- Rated Pump Head {Pa}
+ , !- Rated Power Consumption {W}
+ 0.825, !- Motor Efficiency
+ , !- Fraction of Motor Inefficiencies to Fluid Stream
+ 0, !- Coefficient 1 of the Part Load Performance Curve
+ 3.2485, !- Coefficient 2 of the Part Load Performance Curve
+ -4.7443, !- Coefficient 3 of the Part Load Performance Curve
+ 2.5294, !- Coefficient 4 of the Part Load Performance Curve
+ , !- Minimum Flow Rate {m3/s}
+ Intermittent, !- Pump Control Type
+ , !- Pump Flow Rate Schedule Name
+ , !- Pump Curve Name
+ , !- Impeller Diameter {m}
+ , !- VFD Control Type
+ , !- Pump RPM Schedule Name
+ , !- Minimum Pressure Schedule {Pa}
+ , !- Maximum Pressure Schedule {Pa}
+ , !- Minimum RPM Schedule {rev/min}
+ , !- Maximum RPM Schedule {rev/min}
+ , !- Zone Name
+ 0.5, !- Skin Loss Radiative Fraction
+ PowerPerFlowPerPressure, !- Design Power Sizing Method
+ 348701.1, !- Design Electric Power per Unit Flow Rate {W/(m3/s)}
+ 1.282051282, !- Design Shaft Power per Unit Flow Rate per Unit Head {W-s/m3-Pa}
+ 0, !- Design Minimum Flow Rate Fraction
+ General; !- End-Use Subcategory
+
+OS:Node,
+ {69567b13-1f2e-4d5f-9ed0-674305a0ff43}, !- Handle
+ Hot Water Loop Pump Outlet Water Node, !- Name
+ {c1a655e3-fada-4333-89bf-ccd06cd1a864}, !- Inlet Port
+ {9861e72c-4797-454a-baf5-79dd0dab0f8c}; !- Outlet Port
+
+OS:Connection,
+ {8ba7f860-f16c-4da7-87f0-e9de19ab2076}, !- Handle
+ {5b5b69a7-6289-4993-8110-01085452a4f6}, !- Source Object
+ 3, !- Outlet Port
+ {c80b729a-23e9-4e44-941a-a46d8fc9bb62}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {c1a655e3-fada-4333-89bf-ccd06cd1a864}, !- Handle
+ {c80b729a-23e9-4e44-941a-a46d8fc9bb62}, !- Source Object
+ 3, !- Outlet Port
+ {69567b13-1f2e-4d5f-9ed0-674305a0ff43}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {9861e72c-4797-454a-baf5-79dd0dab0f8c}, !- Handle
+ {69567b13-1f2e-4d5f-9ed0-674305a0ff43}, !- Source Object
+ 3, !- Outlet Port
+ {ee51f920-7a9a-4734-9386-4639e650107b}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Boiler:HotWater,
+ {576400e0-794b-4a18-a8b5-35d807067673}, !- Handle
+ Boiler 247kBtu/hr 0.73 Thermal Eff, !- Name
+ NaturalGas, !- Fuel Type
+ , !- Nominal Capacity {W}
+ 0.73, !- Nominal Thermal Efficiency
+ LeavingBoiler, !- Efficiency Curve Temperature Evaluation Variable
+ {2edbcbc7-d092-4b81-9536-57f3c62aa4f8}, !- Normalized Boiler Efficiency Curve Name
+ , !- Design Water Flow Rate {m3/s}
+ 0, !- Minimum Part Load Ratio
+ 1.2, !- Maximum Part Load Ratio
+ 1, !- Optimum Part Load Ratio
+ {66fdbc5a-7be2-43a7-bfc4-2b1d8eda6437}, !- Boiler Water Inlet Node Name
+ {603ef721-ec78-40db-ad7c-df03c5ce15ea}, !- Boiler Water Outlet Node Name
+ 95.0000000000001, !- Water Outlet Upper Temperature Limit {C}
+ LeavingSetpointModulated, !- Boiler Flow Mode
+ 0, !- On Cycle Parasitic Electric Load {W}
+ 0, !- Off Cycle Parasitic Fuel Load {W}
+ 1, !- Sizing Factor
+ General; !- End-Use Subcategory
+
+OS:Node,
+ {f4f1689b-2b2f-49c2-9571-1008b6e90c3c}, !- Handle
+ Boiler Outlet Water Node, !- Name
+ {603ef721-ec78-40db-ad7c-df03c5ce15ea}, !- Inlet Port
+ {09a9de5f-6782-4cb6-9c8c-d653d489704a}; !- Outlet Port
+
+OS:Connection,
+ {66fdbc5a-7be2-43a7-bfc4-2b1d8eda6437}, !- Handle
+ {d1f0e374-c960-48f6-b4c9-137928ed4097}, !- Source Object
+ 3, !- Outlet Port
+ {576400e0-794b-4a18-a8b5-35d807067673}, !- Target Object
+ 11; !- Inlet Port
+
+OS:Connection,
+ {603ef721-ec78-40db-ad7c-df03c5ce15ea}, !- Handle
+ {576400e0-794b-4a18-a8b5-35d807067673}, !- Source Object
+ 12, !- Outlet Port
+ {f4f1689b-2b2f-49c2-9571-1008b6e90c3c}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {09a9de5f-6782-4cb6-9c8c-d653d489704a}, !- Handle
+ {f4f1689b-2b2f-49c2-9571-1008b6e90c3c}, !- Source Object
+ 3, !- Outlet Port
+ {f6d0575b-f55b-4e12-bb59-f58ac27d5e78}, !- Target Object
+ 3; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {6fbeb8ff-3e52-4022-99b6-110bdc9b2db1}, !- Handle
+ Hot Water Loop Supply Equipment Bypass, !- Name
+ {90b0c153-0e77-48b8-b9a0-736fc18869f4}, !- Inlet Node Name
+ {4a6d8d69-21f5-4ed8-a674-1ad1abc51de7}; !- Outlet Node Name
+
+OS:Node,
+ {2e7ff7c2-3891-4e67-bf00-f2d8e8a47368}, !- Handle
+ Hot Water Loop Supply Equipment Bypass Inlet Water Node, !- Name
+ {28c75f65-5b7f-4b4e-af1d-8919da2bec4f}, !- Inlet Port
+ {90b0c153-0e77-48b8-b9a0-736fc18869f4}; !- Outlet Port
+
+OS:Connection,
+ {28c75f65-5b7f-4b4e-af1d-8919da2bec4f}, !- Handle
+ {ee51f920-7a9a-4734-9386-4639e650107b}, !- Source Object
+ 4, !- Outlet Port
+ {2e7ff7c2-3891-4e67-bf00-f2d8e8a47368}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Node,
+ {c4aa4cae-af22-4193-a0b0-5282c0d5b85c}, !- Handle
+ Hot Water Loop Supply Equipment Bypass Outlet Water Node, !- Name
+ {4a6d8d69-21f5-4ed8-a674-1ad1abc51de7}, !- Inlet Port
+ {b719c2e5-d72c-4dd0-8f4c-37d09d17eb85}; !- Outlet Port
+
+OS:Connection,
+ {90b0c153-0e77-48b8-b9a0-736fc18869f4}, !- Handle
+ {2e7ff7c2-3891-4e67-bf00-f2d8e8a47368}, !- Source Object
+ 3, !- Outlet Port
+ {6fbeb8ff-3e52-4022-99b6-110bdc9b2db1}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {4a6d8d69-21f5-4ed8-a674-1ad1abc51de7}, !- Handle
+ {6fbeb8ff-3e52-4022-99b6-110bdc9b2db1}, !- Source Object
+ 3, !- Outlet Port
+ {c4aa4cae-af22-4193-a0b0-5282c0d5b85c}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {b719c2e5-d72c-4dd0-8f4c-37d09d17eb85}, !- Handle
+ {c4aa4cae-af22-4193-a0b0-5282c0d5b85c}, !- Source Object
+ 3, !- Outlet Port
+ {f6d0575b-f55b-4e12-bb59-f58ac27d5e78}, !- Target Object
+ 4; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {c45d6af0-5789-4ad5-98f0-de136b88773c}, !- Handle
+ Hot Water Loop Coil Bypass, !- Name
+ {84a6b4c4-b948-4d21-8a71-62f7751ee3b6}, !- Inlet Node Name
+ {c3f61ef2-556a-45d0-8cbe-8a53b3ceff45}; !- Outlet Node Name
+
+OS:Node,
+ {0ee5e39b-f7a1-46c7-99f5-5f12e31ff0b1}, !- Handle
+ Hot Water Loop Coil Bypass Outlet Water Node, !- Name
+ {c3f61ef2-556a-45d0-8cbe-8a53b3ceff45}, !- Inlet Port
+ {2cf1aa55-ae45-42ef-9dff-419ee0f71c37}; !- Outlet Port
+
+OS:Connection,
+ {84a6b4c4-b948-4d21-8a71-62f7751ee3b6}, !- Handle
+ {9e819282-23d1-49ad-81f0-2b10940683b6}, !- Source Object
+ 3, !- Outlet Port
+ {c45d6af0-5789-4ad5-98f0-de136b88773c}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {c3f61ef2-556a-45d0-8cbe-8a53b3ceff45}, !- Handle
+ {c45d6af0-5789-4ad5-98f0-de136b88773c}, !- Source Object
+ 3, !- Outlet Port
+ {0ee5e39b-f7a1-46c7-99f5-5f12e31ff0b1}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {2cf1aa55-ae45-42ef-9dff-419ee0f71c37}, !- Handle
+ {0ee5e39b-f7a1-46c7-99f5-5f12e31ff0b1}, !- Source Object
+ 3, !- Outlet Port
+ {f875a8c5-6ca6-4019-aa0e-98d692342249}, !- Target Object
+ 3; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {251df715-a578-4332-a9d6-b25eedfd9fe2}, !- Handle
+ Hot Water Loop Supply Outlet, !- Name
+ {3541954d-76fe-4c8d-bab6-c926b20bccf6}, !- Inlet Node Name
+ {75b8f733-8d98-4041-b8b0-6578ced5566f}; !- Outlet Node Name
+
+OS:Node,
+ {f666da7d-4490-468c-9d75-dc9bc237b958}, !- Handle
+ Hot Water Loop Supply Outlet Inlet Water Node, !- Name
+ {c56186a0-7a55-4ec1-8020-c1dfdfae2607}, !- Inlet Port
+ {3541954d-76fe-4c8d-bab6-c926b20bccf6}; !- Outlet Port
+
+OS:Connection,
+ {c56186a0-7a55-4ec1-8020-c1dfdfae2607}, !- Handle
+ {f6d0575b-f55b-4e12-bb59-f58ac27d5e78}, !- Source Object
+ 2, !- Outlet Port
+ {f666da7d-4490-468c-9d75-dc9bc237b958}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {3541954d-76fe-4c8d-bab6-c926b20bccf6}, !- Handle
+ {f666da7d-4490-468c-9d75-dc9bc237b958}, !- Source Object
+ 3, !- Outlet Port
+ {251df715-a578-4332-a9d6-b25eedfd9fe2}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {75b8f733-8d98-4041-b8b0-6578ced5566f}, !- Handle
+ {251df715-a578-4332-a9d6-b25eedfd9fe2}, !- Source Object
+ 3, !- Outlet Port
+ {9458db6b-be1c-4f23-aff6-8e78ba354999}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {2032c052-2224-4347-bf37-84cd9c74cdac}, !- Handle
+ Hot Water Loop Demand Inlet, !- Name
+ {02f07513-a0b0-4d3e-82b1-7924ed0cf1fb}, !- Inlet Node Name
+ {1299b1e5-5562-4c86-96ba-e08b35619f55}; !- Outlet Node Name
+
+OS:Node,
+ {fcf362d0-1893-4ca5-9e27-cbf000be43d0}, !- Handle
+ Hot Water Loop Demand Inlet Outlet Water Node, !- Name
+ {1299b1e5-5562-4c86-96ba-e08b35619f55}, !- Inlet Port
+ {fa42050d-f85d-459d-993d-4690f9b8a1d9}; !- Outlet Port
+
+OS:Connection,
+ {02f07513-a0b0-4d3e-82b1-7924ed0cf1fb}, !- Handle
+ {801e7621-21b0-4cba-94c9-30680fdf331d}, !- Source Object
+ 3, !- Outlet Port
+ {2032c052-2224-4347-bf37-84cd9c74cdac}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {1299b1e5-5562-4c86-96ba-e08b35619f55}, !- Handle
+ {2032c052-2224-4347-bf37-84cd9c74cdac}, !- Source Object
+ 3, !- Outlet Port
+ {fcf362d0-1893-4ca5-9e27-cbf000be43d0}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {fa42050d-f85d-459d-993d-4690f9b8a1d9}, !- Handle
+ {fcf362d0-1893-4ca5-9e27-cbf000be43d0}, !- Source Object
+ 3, !- Outlet Port
+ {5c995fb9-d20f-4c54-b919-8dcc7d08738b}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Pipe:Adiabatic,
+ {6308d3d2-abd4-49f3-8f57-2cf25f00e2ee}, !- Handle
+ Hot Water Loop Demand Outlet, !- Name
+ {52e03e97-15f2-476d-be73-592a3e440a06}, !- Inlet Node Name
+ {00d8a4b8-3eb1-47a5-823e-cd4e1cf07b81}; !- Outlet Node Name
+
+OS:Node,
+ {eec499f4-bc2c-4ad5-b82d-cd4260455d54}, !- Handle
+ Hot Water Loop Demand Outlet Inlet Water Node, !- Name
+ {4649ce3b-5670-4514-9128-a9b6baa70877}, !- Inlet Port
+ {52e03e97-15f2-476d-be73-592a3e440a06}; !- Outlet Port
+
+OS:Connection,
+ {4649ce3b-5670-4514-9128-a9b6baa70877}, !- Handle
+ {f875a8c5-6ca6-4019-aa0e-98d692342249}, !- Source Object
+ 2, !- Outlet Port
+ {eec499f4-bc2c-4ad5-b82d-cd4260455d54}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {52e03e97-15f2-476d-be73-592a3e440a06}, !- Handle
+ {eec499f4-bc2c-4ad5-b82d-cd4260455d54}, !- Source Object
+ 3, !- Outlet Port
+ {6308d3d2-abd4-49f3-8f57-2cf25f00e2ee}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {00d8a4b8-3eb1-47a5-823e-cd4e1cf07b81}, !- Handle
+ {6308d3d2-abd4-49f3-8f57-2cf25f00e2ee}, !- Source Object
+ 3, !- Outlet Port
+ {fc97d1d1-d261-42c1-b98f-fa00da9724b2}, !- Target Object
+ 2; !- Inlet Port
+
+OS:AirLoopHVAC,
+ {b605de1e-4484-428a-a24f-44f9e68042c0}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC, !- Name
+ , !- Controller List Name
+ {68d41431-321e-4116-9d32-5a6a4124de5d}, !- Availability Schedule
+ {c2a4c4d6-64f5-42cc-936b-b29c1d75b742}, !- Availability Manager List Name
+ autosize, !- Design Supply Air Flow Rate {m3/s}
+ 1, !- Design Return Air Flow Fraction of Supply Air Flow
+ , !- Branch List Name
+ , !- Connector List Name
+ {4ff2a3f9-4d7a-4301-8f1b-2baa66e896ac}, !- Supply Side Inlet Node Name
+ {0a4b548f-4bc5-4b15-8361-72e3c255b805}, !- Demand Side Outlet Node Name
+ {89675e75-0e2c-4d46-8fe7-a2861ba7fe32}, !- Demand Side Inlet Node A
+ {5090b513-004a-47fa-a3e6-aaef48fa422c}, !- Supply Side Outlet Node A
+ , !- Demand Side Inlet Node B
+ , !- Supply Side Outlet Node B
+ , !- Return Air Bypass Flow Temperature Setpoint Schedule Name
+ {cefb47de-c28e-4b5d-96ff-3c88aba50f86}, !- Demand Mixer Name
+ {2edd60b3-e13f-416f-b5f9-b1caa6955c1b}, !- Demand Splitter A Name
+ , !- Demand Splitter B Name
+ ; !- Supply Splitter Name
+
+OS:Node,
+ {3e2ecc66-eccf-4a40-9262-9f988cb81e0d}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Supply Inlet Node, !- Name
+ {4ff2a3f9-4d7a-4301-8f1b-2baa66e896ac}, !- Inlet Port
+ {0d0c2d67-ad81-4326-9be6-e8303f8e721f}; !- Outlet Port
+
+OS:Node,
+ {073cdb6d-acd5-4955-b9f5-d8e9b03319a4}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Supply Outlet Node, !- Name
+ {44b4d2df-8673-432c-9081-f7d57647b753}, !- Inlet Port
+ {5090b513-004a-47fa-a3e6-aaef48fa422c}; !- Outlet Port
+
+OS:Connection,
+ {4ff2a3f9-4d7a-4301-8f1b-2baa66e896ac}, !- Handle
+ {b605de1e-4484-428a-a24f-44f9e68042c0}, !- Source Object
+ 9, !- Outlet Port
+ {3e2ecc66-eccf-4a40-9262-9f988cb81e0d}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {5090b513-004a-47fa-a3e6-aaef48fa422c}, !- Handle
+ {073cdb6d-acd5-4955-b9f5-d8e9b03319a4}, !- Source Object
+ 3, !- Outlet Port
+ {b605de1e-4484-428a-a24f-44f9e68042c0}, !- Target Object
+ 12; !- Inlet Port
+
+OS:Node,
+ {3281ce9d-9b75-40b4-81a1-2197110ba86f}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Demand Inlet Node, !- Name
+ {89675e75-0e2c-4d46-8fe7-a2861ba7fe32}, !- Inlet Port
+ {acf47dd1-68e8-4b55-8e64-ad85a2aff882}; !- Outlet Port
+
+OS:Node,
+ {d0717d5a-93a4-486f-baf9-d3a943e29716}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Demand Outlet Node, !- Name
+ {696f5daa-59e8-48c8-bda5-befd3f8c1de7}, !- Inlet Port
+ {0a4b548f-4bc5-4b15-8361-72e3c255b805}; !- Outlet Port
+
+OS:Node,
+ {95680c9e-25c2-4b46-8765-728cfe1974de}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Diffuser Outlet Air Node, !- Name
+ {76231016-6d35-4047-a1d5-3d784fe87093}, !- Inlet Port
+ {bac6ab62-445d-4d74-bb36-efde746e7354}; !- Outlet Port
+
+OS:Connection,
+ {89675e75-0e2c-4d46-8fe7-a2861ba7fe32}, !- Handle
+ {b605de1e-4484-428a-a24f-44f9e68042c0}, !- Source Object
+ 11, !- Outlet Port
+ {3281ce9d-9b75-40b4-81a1-2197110ba86f}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {0a4b548f-4bc5-4b15-8361-72e3c255b805}, !- Handle
+ {d0717d5a-93a4-486f-baf9-d3a943e29716}, !- Source Object
+ 3, !- Outlet Port
+ {b605de1e-4484-428a-a24f-44f9e68042c0}, !- Target Object
+ 10; !- Inlet Port
+
+OS:AirLoopHVAC:ZoneSplitter,
+ {2edd60b3-e13f-416f-b5f9-b1caa6955c1b}, !- Handle
+ Air Loop HVAC Zone Splitter 1, !- Name
+ {acf47dd1-68e8-4b55-8e64-ad85a2aff882}, !- Inlet Node Name
+ {ed03d6fd-09d1-436e-88bc-9e07a0ad3476}; !- Outlet Node Name 1
+
+OS:AirLoopHVAC:ZoneMixer,
+ {cefb47de-c28e-4b5d-96ff-3c88aba50f86}, !- Handle
+ Air Loop HVAC Zone Mixer 1, !- Name
+ {696f5daa-59e8-48c8-bda5-befd3f8c1de7}, !- Outlet Node Name
+ {72f99c54-ed5c-46a5-98d6-d9b24a903c99}; !- Inlet Node Name 1
+
+OS:Connection,
+ {acf47dd1-68e8-4b55-8e64-ad85a2aff882}, !- Handle
+ {3281ce9d-9b75-40b4-81a1-2197110ba86f}, !- Source Object
+ 3, !- Outlet Port
+ {2edd60b3-e13f-416f-b5f9-b1caa6955c1b}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {696f5daa-59e8-48c8-bda5-befd3f8c1de7}, !- Handle
+ {cefb47de-c28e-4b5d-96ff-3c88aba50f86}, !- Source Object
+ 2, !- Outlet Port
+ {d0717d5a-93a4-486f-baf9-d3a943e29716}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Sizing:System,
+ {73e309b9-d410-49b3-8916-f0610d0c9be5}, !- Handle
+ {b605de1e-4484-428a-a24f-44f9e68042c0}, !- AirLoop Name
+ Sensible, !- Type of Load to Size On
+ Autosize, !- Design Outdoor Air Flow Rate {m3/s}
+ 1, !- Central Heating Maximum System Air Flow Ratio
+ 7.22222222222229, !- Preheat Design Temperature {C}
+ 0.008, !- Preheat Design Humidity Ratio {kg-H2O/kg-Air}
+ 12.7777777777778, !- Precool Design Temperature {C}
+ 0.008, !- Precool Design Humidity Ratio {kg-H2O/kg-Air}
+ 12.7777777777778, !- Central Cooling Design Supply Air Temperature {C}
+ 50.0000000000001, !- Central Heating Design Supply Air Temperature {C}
+ Coincident, !- Sizing Option
+ No, !- 100% Outdoor Air in Cooling
+ No, !- 100% Outdoor Air in Heating
+ 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kg-H2O/kg-Air}
+ 0.008, !- Central Heating Design Supply Air Humidity Ratio {kg-H2O/kg-Air}
+ DesignDay, !- Cooling Design Air Flow Method
+ , !- Cooling Design Air Flow Rate {m3/s}
+ DesignDay, !- Heating Design Air Flow Method
+ , !- Heating Design Air Flow Rate {m3/s}
+ ZoneSum, !- System Outdoor Air Method
+ 1, !- Zone Maximum Outdoor Air Fraction {dimensionless}
+ 0.0099676501, !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2}
+ 1, !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate
+ 3.9475456e-05, !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W}
+ 0.0099676501, !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2}
+ 1, !- Heating Fraction of Autosized Heating Supply Air Flow Rate
+ 1, !- Heating Fraction of Autosized Cooling Supply Air Flow Rate
+ 3.1588213e-05, !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W}
+ CoolingDesignCapacity, !- Cooling Design Capacity Method
+ autosize, !- Cooling Design Capacity {W}
+ 234.7, !- Cooling Design Capacity Per Floor Area {W/m2}
+ 1, !- Fraction of Autosized Cooling Design Capacity
+ HeatingDesignCapacity, !- Heating Design Capacity Method
+ autosize, !- Heating Design Capacity {W}
+ 157, !- Heating Design Capacity Per Floor Area {W/m2}
+ 1, !- Fraction of Autosized Heating Design Capacity
+ OnOff, !- Central Cooling Capacity Control Method
+ autosize; !- Occupant Diversity
+
+OS:AvailabilityManagerAssignmentList,
+ {c2a4c4d6-64f5-42cc-936b-b29c1d75b742}, !- Handle
+ Air Loop HVAC 1 AvailabilityManagerAssignmentList, !- Name
+ {20472f18-f9d5-42e4-8813-b38018363740}; !- Availability Manager Name 1
+
+OS:SetpointManager:SingleZone:Reheat,
+ {7b2024e5-1b88-4390-99d3-c529ec40a5ab}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground Setpoint Manager SZ Reheat, !- Name
+ 12.7777777777778, !- Minimum Supply Air Temperature {C}
+ 50.0000000000001, !- Maximum Supply Air Temperature {C}
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- Control Zone Name
+ {073cdb6d-acd5-4955-b9f5-d8e9b03319a4}; !- Setpoint Node or NodeList Name
+
+OS:Coil:Heating:Water,
+ {d9545115-ebe8-4ae0-bb4c-4ac79d308b70}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Water Htg Coil, !- Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Availability Schedule Name
+ , !- U-Factor Times Area Value {W/K}
+ , !- Maximum Water Flow Rate {m3/s}
+ {0d7ce094-0cc6-4be6-8ed1-7975ff954dda}, !- Water Inlet Node Name
+ {0f674349-070f-4fce-80f7-47dc15d9ce3b}, !- Water Outlet Node Name
+ , !- Air Inlet Node Name
+ , !- Air Outlet Node Name
+ , !- Performance Input Method
+ , !- Rated Capacity {W}
+ 82.2222222222223, !- Rated Inlet Water Temperature {C}
+ 7.22222222222229, !- Rated Inlet Air Temperature {C}
+ 71.1111111111112, !- Rated Outlet Water Temperature {C}
+ 50.0000000000001, !- Rated Outlet Air Temperature {C}
+ ; !- Rated Ratio for Air and Water Convection
+
+OS:Node,
+ {34e3fab8-791d-4c1b-9af9-8eec95e882a8}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Water Htg Coil Inlet Water Node, !- Name
+ {eec653c3-d314-4a0b-a11c-23ac10c66d61}, !- Inlet Port
+ {0d7ce094-0cc6-4be6-8ed1-7975ff954dda}; !- Outlet Port
+
+OS:Connection,
+ {eec653c3-d314-4a0b-a11c-23ac10c66d61}, !- Handle
+ {5c995fb9-d20f-4c54-b919-8dcc7d08738b}, !- Source Object
+ 4, !- Outlet Port
+ {34e3fab8-791d-4c1b-9af9-8eec95e882a8}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Node,
+ {8379baa6-f836-4211-babe-08d886973aec}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Water Htg Coil Outlet Water Node, !- Name
+ {0f674349-070f-4fce-80f7-47dc15d9ce3b}, !- Inlet Port
+ {fe7c6ef1-03ab-4ac4-b95e-56d0613ed249}; !- Outlet Port
+
+OS:Connection,
+ {0d7ce094-0cc6-4be6-8ed1-7975ff954dda}, !- Handle
+ {34e3fab8-791d-4c1b-9af9-8eec95e882a8}, !- Source Object
+ 3, !- Outlet Port
+ {d9545115-ebe8-4ae0-bb4c-4ac79d308b70}, !- Target Object
+ 5; !- Inlet Port
+
+OS:Connection,
+ {0f674349-070f-4fce-80f7-47dc15d9ce3b}, !- Handle
+ {d9545115-ebe8-4ae0-bb4c-4ac79d308b70}, !- Source Object
+ 6, !- Outlet Port
+ {8379baa6-f836-4211-babe-08d886973aec}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {fe7c6ef1-03ab-4ac4-b95e-56d0613ed249}, !- Handle
+ {8379baa6-f836-4211-babe-08d886973aec}, !- Source Object
+ 3, !- Outlet Port
+ {f875a8c5-6ca6-4019-aa0e-98d692342249}, !- Target Object
+ 4; !- Inlet Port
+
+OS:Controller:WaterCoil,
+ {37924924-9ed2-41fb-b032-2e33952c2873}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Water Htg Coil Controller, !- Name
+ {d9545115-ebe8-4ae0-bb4c-4ac79d308b70}, !- Water Coil Name
+ , !- Control Variable
+ Normal, !- Action
+ , !- Actuator Variable
+ , !- Sensor Node Name
+ , !- Actuator Node Name
+ 0.0001, !- Controller Convergence Tolerance {deltaC}
+ , !- Maximum Actuated Flow {m3/s}
+ 0; !- Minimum Actuated Flow {m3/s}
+
+OS:Coil:Heating:Electric,
+ {d2a4b815-2b60-496a-a10c-b08c8474a00c}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Electric Backup Htg Coil, !- Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Availability Schedule Name
+ 1, !- Efficiency
+ , !- Nominal Capacity {W}
+ , !- Air Inlet Node Name
+ ; !- Air Outlet Node Name
+
+OS:Coil:Cooling:DX:SingleSpeed,
+ {b766c095-8406-42fb-b628-a4339b7579bb}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC 1spd DX AC Clg Coil 128kBtu/hr 9.63EER, !- Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Availability Schedule Name
+ autosize, !- Rated Total Cooling Capacity {W}
+ autosize, !- Rated Sensible Heat Ratio
+ 3.34349364290739, !- Rated COP {W/W}
+ autosize, !- Rated Air Flow Rate {m3/s}
+ 773.3, !- Rated Evaporator Fan Power Per Volume Flow Rate 2017 {W/(m3/s)}
+ 934.4, !- Rated Evaporator Fan Power Per Volume Flow Rate 2023 {W/(m3/s)}
+ , !- Air Inlet Node Name
+ , !- Air Outlet Node Name
+ {b91b60f7-3eb3-4347-92ab-948af7c57808}, !- Total Cooling Capacity Function of Temperature Curve Name
+ {32fcd20e-5d7c-4f54-9bfc-7ea1e52e72d9}, !- Total Cooling Capacity Function of Flow Fraction Curve Name
+ {7e8c3aa1-78d8-46c9-8b5a-8f5f54b5a9f8}, !- Energy Input Ratio Function of Temperature Curve Name
+ {c82e87f7-9aab-457d-beef-d037ee88af0a}, !- Energy Input Ratio Function of Flow Fraction Curve Name
+ {5555e62f-8fc3-47ab-8a69-99510cc6adce}, !- Part Load Fraction Correlation Curve Name
+ -25, !- Minimum Outdoor Dry-Bulb Temperature for Compressor Operation {C}
+ 0, !- Nominal Time for Condensate Removal to Begin {s}
+ 0, !- Ratio of Initial Moisture Evaporation Rate and Steady State Latent Capacity {dimensionless}
+ 0, !- Maximum Cycling Rate {cycles/hr}
+ 0, !- Latent Capacity Time Constant {s}
+ , !- Condenser Air Inlet Node Name
+ AirCooled, !- Condenser Type
+ 0.9, !- Evaporative Condenser Effectiveness {dimensionless}
+ autosize, !- Evaporative Condenser Air Flow Rate {m3/s}
+ autosize, !- Evaporative Condenser Pump Rated Power Consumption {W}
+ 0, !- Crankcase Heater Capacity {W}
+ , !- Crankcase Heater Capacity Function of Temperature Curve Name
+ 10, !- Maximum Outdoor Dry-Bulb Temperature for Crankcase Heater Operation {C}
+ , !- Supply Water Storage Tank Name
+ , !- Condensate Collection Water Storage Tank Name
+ 0, !- Basin Heater Capacity {W/K}
+ 2; !- Basin Heater Setpoint Temperature {C}
+
+OS:Fan:OnOff,
+ {2840a1ed-600d-4d86-8d5c-712be62a2cc3}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Fan, !- Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Availability Schedule Name
+ 0.56875, !- Fan Total Efficiency
+ 622.722275, !- Pressure Rise {Pa}
+ autosize, !- Maximum Flow Rate {m3/s}
+ 0.875, !- Motor Efficiency
+ 1, !- Motor In Airstream Fraction
+ , !- Air Inlet Node Name
+ , !- Air Outlet Node Name
+ {1b575c22-d20a-44f3-9fe8-78ed0d9a849a}, !- Fan Power Ratio Function of Speed Ratio Curve Name
+ {9824c24f-8c7a-4eed-ab46-569bb7bdb1d2}, !- Fan Efficiency Ratio Function of Speed Ratio Curve Name
+ ; !- End-Use Subcategory
+
+OS:Curve:Exponent,
+ {1b575c22-d20a-44f3-9fe8-78ed0d9a849a}, !- Handle
+ Fan On Off Power Curve, !- Name
+ 1, !- Coefficient1 Constant
+ 0, !- Coefficient2 Constant
+ 0, !- Coefficient3 Constant
+ 0, !- Minimum Value of x
+ 1, !- Maximum Value of x
+ , !- Minimum Curve Output
+ , !- Maximum Curve Output
+ , !- Input Unit Type for X
+ ; !- Output Unit Type
+
+OS:Curve:Cubic,
+ {9824c24f-8c7a-4eed-ab46-569bb7bdb1d2}, !- Handle
+ Fan On Off Efficiency Curve, !- Name
+ 1, !- Coefficient1 Constant
+ 0, !- Coefficient2 x
+ 0, !- Coefficient3 x**2
+ 0, !- Coefficient4 x**3
+ 0, !- Minimum Value of x
+ 1; !- Maximum Value of x
+
+OS:AirLoopHVAC:UnitarySystem,
+ {a26aa34a-00b1-4d4c-8970-0abe47bee2d0}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Unitary AC, !- Name
+ Load, !- Control Type
+ {5f8deca6-f8f0-46dc-a050-bf52883a1bf1}, !- Controlling Zone or Thermostat Location
+ None, !- Dehumidification Control Type
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Availability Schedule Name
+ {13fac174-61ae-45e7-8ab5-f8c8b44fc307}, !- Air Inlet Node Name
+ {44b4d2df-8673-432c-9081-f7d57647b753}, !- Air Outlet Node Name
+ {2840a1ed-600d-4d86-8d5c-712be62a2cc3}, !- Supply Fan Name
+ DrawThrough, !- Fan Placement
+ {68d41431-321e-4116-9d32-5a6a4124de5d}, !- Supply Air Fan Operating Mode Schedule Name
+ {d9545115-ebe8-4ae0-bb4c-4ac79d308b70}, !- Heating Coil Name
+ 1, !- DX Heating Coil Sizing Ratio
+ {b766c095-8406-42fb-b628-a4339b7579bb}, !- Cooling Coil Name
+ No, !- Use DOAS DX Cooling Coil
+ 2, !- DOAS DX Cooling Coil Leaving Minimum Air Temperature {C}
+ SensibleOnlyLoadControl, !- Latent Load Control
+ {d2a4b815-2b60-496a-a10c-b08c8474a00c}, !- Supplemental Heating Coil Name
+ SupplyAirFlowRate, !- Supply Air Flow Rate Method During Cooling Operation
+ Autosize, !- Supply Air Flow Rate During Cooling Operation {m3/s}
+ , !- Supply Air Flow Rate Per Floor Area During Cooling Operation {m3/s-m2}
+ , !- Fraction of Autosized Design Cooling Supply Air Flow Rate
+ , !- Design Supply Air Flow Rate Per Unit of Capacity During Cooling Operation {m3/s-W}
+ SupplyAirFlowRate, !- Supply Air Flow Rate Method During Heating Operation
+ Autosize, !- Supply Air Flow Rate During Heating Operation {m3/s}
+ , !- Supply Air Flow Rate Per Floor Area during Heating Operation {m3/s-m2}
+ , !- Fraction of Autosized Design Heating Supply Air Flow Rate
+ , !- Design Supply Air Flow Rate Per Unit of Capacity During Heating Operation {m3/s-W}
+ None, !- Supply Air Flow Rate Method When No Cooling or Heating is Required
+ , !- Supply Air Flow Rate When No Cooling or Heating is Required {m3/s}
+ , !- Supply Air Flow Rate Per Floor Area When No Cooling or Heating is Required {m3/s-m2}
+ , !- Fraction of Autosized Design Cooling Supply Air Flow Rate When No Cooling or Heating is Required
+ , !- Fraction of Autosized Design Heating Supply Air Flow Rate When No Cooling or Heating is Required
+ , !- Design Supply Air Flow Rate Per Unit of Capacity During Cooling Operation When No Cooling or Heating is Required {m3/s-W}
+ , !- Design Supply Air Flow Rate Per Unit of Capacity During Heating Operation When No Cooling or Heating is Required {m3/s-W}
+ Yes, !- No Load Supply Air Flow Rate Control Set To Low Speed
+ 80, !- Maximum Supply Air Temperature {C}
+ 21, !- Maximum Outdoor Dry-Bulb Temperature for Supplemental Heater Operation {C}
+ , !- Outdoor Dry-Bulb Temperature Sensor Node Name
+ 0, !- Ancilliary On-Cycle Electric Power {W}
+ 0; !- Ancilliary Off-Cycle Electric Power {W}
+
+OS:Connection,
+ {44b4d2df-8673-432c-9081-f7d57647b753}, !- Handle
+ {a26aa34a-00b1-4d4c-8970-0abe47bee2d0}, !- Source Object
+ 7, !- Outlet Port
+ {073cdb6d-acd5-4955-b9f5-d8e9b03319a4}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Controller:OutdoorAir,
+ {3b9cb1b8-9df7-4d03-bbd0-68c7a8f092b2}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC OA System Controller, !- Name
+ , !- Relief Air Outlet Node Name
+ , !- Return Air Node Name
+ , !- Mixed Air Node Name
+ , !- Actuator Node Name
+ autosize, !- Minimum Outdoor Air Flow Rate {m3/s}
+ Autosize, !- Maximum Outdoor Air Flow Rate {m3/s}
+ FixedDryBulb, !- Economizer Control Type
+ ModulateFlow, !- Economizer Control Action Type
+ 23.8888888888889, !- Economizer Maximum Limit Dry-Bulb Temperature {C}
+ , !- Economizer Maximum Limit Enthalpy {J/kg}
+ , !- Economizer Maximum Limit Dewpoint Temperature {C}
+ , !- Electronic Enthalpy Limit Curve Name
+ , !- Economizer Minimum Limit Dry-Bulb Temperature {C}
+ LockoutWithCompressor, !- Lockout Type
+ FixedMinimum, !- Minimum Limit Type
+ {68d41431-321e-4116-9d32-5a6a4124de5d}, !- Minimum Outdoor Air Schedule Name
+ , !- Minimum Fraction of Outdoor Air Schedule Name
+ , !- Maximum Fraction of Outdoor Air Schedule Name
+ {a97ac60a-c4fe-4218-9881-6541cf9be699}, !- Controller Mechanical Ventilation
+ , !- Time of Day Economizer Control Schedule Name
+ No, !- High Humidity Control
+ , !- Humidistat Control Zone Name
+ , !- High Humidity Outdoor Air Flow Ratio
+ , !- Control High Indoor Humidity Based on Outdoor Humidity Ratio
+ BypassWhenWithinEconomizerLimits, !- Heat Recovery Bypass Control Type
+ InterlockedWithMechanicalCooling; !- Economizer Operation Staging
+
+OS:Controller:MechanicalVentilation,
+ {a97ac60a-c4fe-4218-9881-6541cf9be699}, !- Handle
+ Controller Mechanical Ventilation 1, !- Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Availability Schedule
+ , !- Demand Controlled Ventilation
+ ; !- System Outdoor Air Method
+
+OS:AirLoopHVAC:OutdoorAirSystem,
+ {72941f18-484a-433b-aa2a-c304630b1be8}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC OA System, !- Name
+ {3b9cb1b8-9df7-4d03-bbd0-68c7a8f092b2}, !- Controller Name
+ , !- Outdoor Air Equipment List Name
+ , !- Availability Manager List Name
+ {4aea51c8-4617-469c-9d62-c7b934d07965}, !- Mixed Air Node Name
+ {84bc2b3a-1388-415a-aa53-485c75cbea24}, !- Outdoor Air Stream Node Name
+ {ef7be3ae-55aa-45ec-97dc-753e15b37cb1}, !- Relief Air Stream Node Name
+ {0d0c2d67-ad81-4326-9be6-e8303f8e721f}; !- Return Air Stream Node Name
+
+OS:Node,
+ {920577ef-9709-42f1-9d65-60f86f95ea86}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Outdoor Air Node, !- Name
+ , !- Inlet Port
+ {84bc2b3a-1388-415a-aa53-485c75cbea24}; !- Outlet Port
+
+OS:Connection,
+ {84bc2b3a-1388-415a-aa53-485c75cbea24}, !- Handle
+ {920577ef-9709-42f1-9d65-60f86f95ea86}, !- Source Object
+ 3, !- Outlet Port
+ {72941f18-484a-433b-aa2a-c304630b1be8}, !- Target Object
+ 6; !- Inlet Port
+
+OS:Node,
+ {635cd140-57a2-43df-891b-fcedb7455089}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Relief Air Node, !- Name
+ {ef7be3ae-55aa-45ec-97dc-753e15b37cb1}, !- Inlet Port
+ ; !- Outlet Port
+
+OS:Connection,
+ {ef7be3ae-55aa-45ec-97dc-753e15b37cb1}, !- Handle
+ {72941f18-484a-433b-aa2a-c304630b1be8}, !- Source Object
+ 7, !- Outlet Port
+ {635cd140-57a2-43df-891b-fcedb7455089}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Node,
+ {f19b829f-7f6d-457b-ad26-769d1c17da13}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Mixed Air Node, !- Name
+ {4aea51c8-4617-469c-9d62-c7b934d07965}, !- Inlet Port
+ {13fac174-61ae-45e7-8ab5-f8c8b44fc307}; !- Outlet Port
+
+OS:Connection,
+ {0d0c2d67-ad81-4326-9be6-e8303f8e721f}, !- Handle
+ {3e2ecc66-eccf-4a40-9262-9f988cb81e0d}, !- Source Object
+ 3, !- Outlet Port
+ {72941f18-484a-433b-aa2a-c304630b1be8}, !- Target Object
+ 8; !- Inlet Port
+
+OS:Connection,
+ {4aea51c8-4617-469c-9d62-c7b934d07965}, !- Handle
+ {72941f18-484a-433b-aa2a-c304630b1be8}, !- Source Object
+ 5, !- Outlet Port
+ {f19b829f-7f6d-457b-ad26-769d1c17da13}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {13fac174-61ae-45e7-8ab5-f8c8b44fc307}, !- Handle
+ {f19b829f-7f6d-457b-ad26-769d1c17da13}, !- Source Object
+ 3, !- Outlet Port
+ {a26aa34a-00b1-4d4c-8970-0abe47bee2d0}, !- Target Object
+ 6; !- Inlet Port
+
+OS:AvailabilityManager:NightCycle,
+ {20472f18-f9d5-42e4-8813-b38018363740}, !- Handle
+ Availability Manager Night Cycle 1, !- Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Applicability Schedule
+ , !- Fan Schedule
+ CycleOnAny, !- Control Type
+ 1.9999, !- Thermostat Tolerance {deltaC}
+ Thermostat, !- Cycling Run Time Control Type
+ 1800, !- Cycling Run Time {s}
+ {89d9d232-d7cb-42a7-b1b5-f30406060585}, !- Control Zone or Zone List Name
+ {6c1c50f4-faf1-4cea-b7b9-88ebc12dbc53}, !- Cooling Control Zone or Zone List Name
+ {0ccdb32d-6c92-4cad-90d8-8a4354629bb6}, !- Heating Control Zone or Zone List Name
+ {e655b119-8680-4fce-91dc-584bb305b247}; !- Heating Zone Fans Only Zone or Zone List Name
+
+OS:ModelObjectList,
+ {89d9d232-d7cb-42a7-b1b5-f30406060585}, !- Handle
+ Availability Manager Night Cycle 1 Control Zone List; !- Name
+
+OS:ModelObjectList,
+ {6c1c50f4-faf1-4cea-b7b9-88ebc12dbc53}, !- Handle
+ Availability Manager Night Cycle 1 Cooling Control Zone List; !- Name
+
+OS:ModelObjectList,
+ {0ccdb32d-6c92-4cad-90d8-8a4354629bb6}, !- Handle
+ Availability Manager Night Cycle 1 Heating Control Zone List; !- Name
+
+OS:ModelObjectList,
+ {e655b119-8680-4fce-91dc-584bb305b247}, !- Handle
+ Availability Manager Night Cycle 1 Heating Zone Fans Only Zone List; !- Name
+
+OS:AirTerminal:SingleDuct:ConstantVolume:NoReheat,
+ {b6083448-e7f2-43a3-8f8e-63a4ef78dff8}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Diffuser, !- Name
+ {1380f75d-3079-4274-b521-055f01fb8026}, !- Availability Schedule Name
+ {1fa363a4-4eb5-4e75-bcb0-ce37596e44ae}, !- Air Inlet Node Name
+ {76231016-6d35-4047-a1d5-3d784fe87093}, !- Air Outlet Node Name
+ AutoSize; !- Maximum Air Flow Rate {m3/s}
+
+OS:Node,
+ {00c7e53b-e03f-4d79-8546-131d3631cd4e}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground Return Air Node, !- Name
+ {61c23f50-5a9d-4fdf-8104-66aad6726319}, !- Inlet Port
+ {72f99c54-ed5c-46a5-98d6-d9b24a903c99}; !- Outlet Port
+
+OS:Connection,
+ {bac6ab62-445d-4d74-bb36-efde746e7354}, !- Handle
+ {95680c9e-25c2-4b46-8765-728cfe1974de}, !- Source Object
+ 3, !- Outlet Port
+ {18712918-a872-478d-8031-a535d2036264}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {61c23f50-5a9d-4fdf-8104-66aad6726319}, !- Handle
+ {f106ff60-dc30-4089-aa91-bca99a72d7c4}, !- Source Object
+ 2, !- Outlet Port
+ {00c7e53b-e03f-4d79-8546-131d3631cd4e}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {72f99c54-ed5c-46a5-98d6-d9b24a903c99}, !- Handle
+ {00c7e53b-e03f-4d79-8546-131d3631cd4e}, !- Source Object
+ 3, !- Outlet Port
+ {cefb47de-c28e-4b5d-96ff-3c88aba50f86}, !- Target Object
+ 3; !- Inlet Port
+
+OS:Node,
+ {06d82eee-c393-4135-a0ef-fddb2e74e049}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Diffuser Inlet Air Node, !- Name
+ {ed03d6fd-09d1-436e-88bc-9e07a0ad3476}, !- Inlet Port
+ {1fa363a4-4eb5-4e75-bcb0-ce37596e44ae}; !- Outlet Port
+
+OS:Connection,
+ {ed03d6fd-09d1-436e-88bc-9e07a0ad3476}, !- Handle
+ {2edd60b3-e13f-416f-b5f9-b1caa6955c1b}, !- Source Object
+ 3, !- Outlet Port
+ {06d82eee-c393-4135-a0ef-fddb2e74e049}, !- Target Object
+ 2; !- Inlet Port
+
+OS:Connection,
+ {1fa363a4-4eb5-4e75-bcb0-ce37596e44ae}, !- Handle
+ {06d82eee-c393-4135-a0ef-fddb2e74e049}, !- Source Object
+ 3, !- Outlet Port
+ {b6083448-e7f2-43a3-8f8e-63a4ef78dff8}, !- Target Object
+ 3; !- Inlet Port
+
+OS:Connection,
+ {76231016-6d35-4047-a1d5-3d784fe87093}, !- Handle
+ {b6083448-e7f2-43a3-8f8e-63a4ef78dff8}, !- Source Object
+ 4, !- Outlet Port
+ {95680c9e-25c2-4b46-8765-728cfe1974de}, !- Target Object
+ 2; !- Inlet Port
+
+OS:AdditionalProperties,
+ {e046232e-11e1-4a07-9933-98445218f751}, !- Handle
+ {3356aedb-116e-430d-91d1-31f2b67492b4}, !- Object Name
+ hvac_system_type, !- Feature Name 1
+ String, !- Feature Data Type 1
+ Inferred; !- Feature Value 1
+
+OS:Sizing:Parameters,
+ {a71a048a-0bdd-4d4f-b611-81cbddb6f9b6}, !- Handle
+ 1.25, !- Heating Sizing Factor
+ 1.15; !- Cooling Sizing Factor
+
+OS:SimulationControl,
+ {31cdc826-23a2-477f-8136-b8afb45f1d1f}, !- Handle
+ Yes, !- Do Zone Sizing Calculation
+ Yes, !- Do System Sizing Calculation
+ Yes, !- Do Plant Sizing Calculation
+ No, !- Run Simulation for Sizing Periods
+ Yes, !- Run Simulation for Weather File Run Periods
+ , !- Loads Convergence Tolerance Value {W}
+ , !- Temperature Convergence Tolerance Value {deltaC}
+ , !- Solar Distribution
+ , !- Maximum Number of Warmup Days
+ , !- Minimum Number of Warmup Days
+ No, !- Do HVAC Sizing Simulation for Sizing Periods
+ 1; !- Maximum Number of HVAC Sizing Simulation Passes
+
+OS:Schedule:Ruleset,
+ {68d41431-321e-4116-9d32-5a6a4124de5d}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Occ Sch, !- Name
+ {b5141937-a292-414b-a754-572e4097c022}, !- Schedule Type Limits Name
+ {d0b8b57b-a037-4b6b-bf3a-c974f35277e8}, !- Default Day Schedule Name
+ {4f1f33b5-0bf9-4b61-becf-1203f1e300a2}, !- Summer Design Day Schedule Name
+ {8fd96dc8-0d05-41f3-9db2-e85ed43c8fa6}; !- Winter Design Day Schedule Name
+
+OS:Schedule:Day,
+ {d0b8b57b-a037-4b6b-bf3a-c974f35277e8}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Occ Sch Default, !- Name
+ {b5141937-a292-414b-a754-572e4097c022}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 7, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 18, !- Hour 2
+ 0, !- Minute 2
+ 1, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 0; !- Value Until Time 3
+
+OS:AdditionalProperties,
+ {d5a57b88-2004-4014-9212-1772f1b79b27}, !- Handle
+ {68d41431-321e-4116-9d32-5a6a4124de5d}, !- Object Name
+ max_occ_in_spaces, !- Feature Name 1
+ Double, !- Feature Data Type 1
+ 17.500000000000039, !- Feature Value 1
+ number_of_spaces_included, !- Feature Name 2
+ Integer, !- Feature Data Type 2
+ 1, !- Feature Value 2
+ date_parent_object_last_edited, !- Feature Name 3
+ String, !- Feature Data Type 3
+ 2024-09-24 18:56:25 UTC, !- Feature Value 3
+ date_parent_object_created, !- Feature Name 4
+ String, !- Feature Data Type 4
+ 2024-09-24 18:56:25 UTC; !- Feature Value 4
+
+OS:Schedule:Day,
+ {8fd96dc8-0d05-41f3-9db2-e85ed43c8fa6}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Occ Sch Winter Design Day, !- Name
+ {b5141937-a292-414b-a754-572e4097c022}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 1; !- Value Until Time 1
+
+OS:Schedule:Day,
+ {4f1f33b5-0bf9-4b61-becf-1203f1e300a2}, !- Handle
+ Zone Office WholeBuilding - Sm Office - Story ground PSZ-AC Occ Sch Summer Design Day, !- Name
+ {b5141937-a292-414b-a754-572e4097c022}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 1; !- Value Until Time 1
+
+OS:Schedule:Rule,
+ {a95240c6-f850-4664-892e-1d18d8b5ba7d}, !- Handle
+ Schedule Rule 17, !- Name
+ {68d41431-321e-4116-9d32-5a6a4124de5d}, !- Schedule Ruleset Name
+ 1, !- Rule Order
+ {51aab576-9160-4d45-8487-bbf8f8699184}, !- Day Schedule Name
+ , !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ Yes, !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 6, !- Start Day
+ 12, !- End Month
+ 29; !- End Day
+
+OS:Schedule:Day,
+ {51aab576-9160-4d45-8487-bbf8f8699184}, !- Handle
+ Schedule Day 19, !- Name
+ {b5141937-a292-414b-a754-572e4097c022}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 8, !- Hour 1
+ 0, !- Minute 1
+ 0, !- Value Until Time 1
+ 12, !- Hour 2
+ 0, !- Minute 2
+ 1, !- Value Until Time 2
+ 24, !- Hour 3
+ 0, !- Minute 3
+ 0; !- Value Until Time 3
+
+OS:Schedule:Rule,
+ {4e88ade3-dd4a-4241-8e28-2dd2af2c4cbb}, !- Handle
+ Schedule Rule 18, !- Name
+ {68d41431-321e-4116-9d32-5a6a4124de5d}, !- Schedule Ruleset Name
+ 0, !- Rule Order
+ {ec5f10e6-07be-4761-855f-b8f0ecd373db}, !- Day Schedule Name
+ Yes, !- Apply Sunday
+ , !- Apply Monday
+ , !- Apply Tuesday
+ , !- Apply Wednesday
+ , !- Apply Thursday
+ , !- Apply Friday
+ , !- Apply Saturday
+ DateRange, !- Date Specification Type
+ 1, !- Start Month
+ 7, !- Start Day
+ 12, !- End Month
+ 30; !- End Day
+
+OS:Schedule:Day,
+ {ec5f10e6-07be-4761-855f-b8f0ecd373db}, !- Handle
+ Schedule Day 20, !- Name
+ {b5141937-a292-414b-a754-572e4097c022}, !- Schedule Type Limits Name
+ , !- Interpolate to Timestep
+ 24, !- Hour 1
+ 0, !- Minute 1
+ 0; !- Value Until Time 1
+
+OS:ScheduleTypeLimits,
+ {b5141937-a292-414b-a754-572e4097c022}, !- Handle
+ ControlMode, !- Name
+ 0, !- Lower Limit Value
+ 1, !- Upper Limit Value
+ Discrete, !- Numeric Type
+ ControlMode; !- Unit Type
+
+OS:Curve:Biquadratic,
+ {b91b60f7-3eb3-4347-92ab-948af7c57808}, !- Handle
+ DOE Ref DX Clg Coil Cool-Cap-fT, !- Name
+ 0.9712123, !- Coefficient1 Constant
+ -0.015275502, !- Coefficient2 x
+ 0.0014434524, !- Coefficient3 x**2
+ -0.00039321, !- Coefficient4 y
+ -6.8364e-06, !- Coefficient5 y**2
+ -0.0002905956, !- Coefficient6 x*y
+ -100, !- Minimum Value of x
+ 100, !- Maximum Value of x
+ -100, !- Minimum Value of y
+ 100; !- Maximum Value of y
+
+OS:Curve:Cubic,
+ {32fcd20e-5d7c-4f54-9bfc-7ea1e52e72d9}, !- Handle
+ DOE Ref DX Clg Coil Cool-CAP-fFlow, !- Name
+ 1, !- Coefficient1 Constant
+ 0, !- Coefficient2 x
+ 0, !- Coefficient3 x**2
+ 0, !- Coefficient4 x**3
+ -100, !- Minimum Value of x
+ 100; !- Maximum Value of x
+
+OS:Curve:Biquadratic,
+ {7e8c3aa1-78d8-46c9-8b5a-8f5f54b5a9f8}, !- Handle
+ DOE Ref DX Clg Coil Cool-EIR-fT, !- Name
+ 0.28687133, !- Coefficient1 Constant
+ 0.023902164, !- Coefficient2 x
+ -0.000810648, !- Coefficient3 x**2
+ 0.013458546, !- Coefficient4 y
+ 0.0003389364, !- Coefficient5 y**2
+ -0.0004870044, !- Coefficient6 x*y
+ -100, !- Minimum Value of x
+ 100, !- Maximum Value of x
+ -100, !- Minimum Value of y
+ 100; !- Maximum Value of y
+
+OS:Curve:Cubic,
+ {c82e87f7-9aab-457d-beef-d037ee88af0a}, !- Handle
+ DOE Ref DX Clg Coil Cool-EIR-fFlow, !- Name
+ 1, !- Coefficient1 Constant
+ 0, !- Coefficient2 x
+ 0, !- Coefficient3 x**2
+ 0, !- Coefficient4 x**3
+ -100, !- Minimum Value of x
+ 100; !- Maximum Value of x
+
+OS:Curve:Quadratic,
+ {5555e62f-8fc3-47ab-8a69-99510cc6adce}, !- Handle
+ DOE Ref DX Clg Coil Cool-PLF-fPLR, !- Name
+ 0.90949556, !- Coefficient1 Constant
+ 0.09864773, !- Coefficient2 x
+ -0.00819488, !- Coefficient3 x**2
+ 0, !- Minimum Value of x
+ 1; !- Maximum Value of x
+
+OS:Curve:Cubic,
+ {2edbcbc7-d092-4b81-9536-57f3c62aa4f8}, !- Handle
+ Boiler Constant Efficiency Curve, !- Name
+ 1, !- Coefficient1 Constant
+ 0, !- Coefficient2 x
+ 0, !- Coefficient3 x**2
+ 0, !- Coefficient4 x**3
+ 0, !- Minimum Value of x
+ 1; !- Maximum Value of x
+
+OS:OutputControl:ReportingTolerances,
+ {c1cb3daf-feb8-498b-9b1e-3ab99923f428}, !- Handle
+ 0.555555555555556, !- Tolerance for Time Heating Setpoint Not Met {deltaC}
+ 0.555555555555556; !- Tolerance for Time Cooling Setpoint Not Met {deltaC}
+
+OS:Facility,
+ {ebe3ceeb-4951-4d8e-b16b-c15938c7bb6a}; !- Handle
+
+OS:ShadowCalculation,
+ {b44e801e-f8bd-4472-847b-06efb73832af}, !- Handle
+ PolygonClipping, !- Shading Calculation Method
+ , !- Shading Calculation Update Frequency Method
+ 20, !- Shading Calculation Update Frequency
+ 15000, !- Maximum Figures in Shadow Overlap Calculations
+ , !- Polygon Clipping Algorithm
+ 512, !- Pixel Counting Resolution
+ , !- Sky Diffuse Modeling Algorithm
+ No, !- Output External Shading Calculation Results
+ No, !- Disable Self-Shading Within Shading Zone Groups
+ No; !- Disable Self-Shading From Shading Zone Groups to Other Zones
+
+OS:HeatBalanceAlgorithm,
+ {48e13834-1a9d-4fcc-bc9f-15a03a5c1e11}, !- Handle
+ ConductionTransferFunction, !- Algorithm
+ 200; !- Surface Temperature Upper Limit {C}
+
+OS:LifeCycleCost:Parameters,
+ {cb4397f8-595d-4364-a5ba-abdcfc2f7a14}, !- Handle
+ , !- Analysis Type
+ , !- Discounting Convention
+ , !- Inflation Approach
+ , !- Real Discount Rate
+ , !- Nominal Discount Rate
+ , !- Inflation
+ , !- Base Date Month
+ , !- Base Date Year
+ , !- Service Date Month
+ , !- Service Date Year
+ ; !- Length of Study Period in Years
+
+OS:StandardsInformation:Material,
+ {792f46b2-decc-4d3d-96aa-197f6212a444}, !- Handle
+ {89f4529a-9f2a-4f93-9d8a-65cb5ced96e5}; !- Material Name
+
+OS:StandardsInformation:Construction,
+ {6f146ce4-add6-41e6-b901-0c48db5ff910}, !- Handle
+ {13e6c855-3a65-406b-b8da-78b7bc6759d6}; !- Construction Name
+
+OS:StandardsInformation:Material,
+ {861fe5dd-e117-4e8c-a210-264229cdfe2e}, !- Handle
+ {b42b5042-e52e-48cf-910d-b9562cb2b53e}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {e29dbc1e-bc10-4f0b-861a-627512fe5576}, !- Handle
+ {6e8a037e-d01d-4b89-bfac-1a10c2955410}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {2d643156-d6ce-48df-94be-a0d9984e73a8}, !- Handle
+ {14ecbd0a-d02e-4c6d-9e68-ecc89392cb6a}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {2d0b1130-7a2b-46dd-948d-c5a525367949}, !- Handle
+ {8f5d7d17-c063-42c3-a65c-e1e4f3fb8233}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {a72ac13a-2d05-497d-9418-dbac04029293}, !- Handle
+ {effbbb2d-afe0-484a-8155-77b05b7846a0}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {3337b98f-e2a3-4678-aaf5-450eec1d3a28}, !- Handle
+ {ce2f72e5-e930-42ef-8582-0f9e0279c550}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {1e4bd2ff-fa85-4894-99a1-c477ec20de5e}, !- Handle
+ {5ef34cb0-9fe9-4560-b71d-608593cf084a}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {aae0ab05-91f1-4d8d-accc-7ed7a790283d}, !- Handle
+ {39e18fdb-601f-4a7b-accd-288065a06e81}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {cf9673b3-0748-4bdd-a8c3-158e540fdd91}, !- Handle
+ {b990dbff-64ca-469b-b057-806c4023155c}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {8475234c-2fa6-4edc-ab0a-cdd00ec51792}, !- Handle
+ {ec74f628-4d78-42a2-a542-cda843f4aa27}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {def6e36d-c505-4674-abe8-5485db20716b}, !- Handle
+ {7ff61b74-57ab-49a5-8563-135ec3fe148e}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {e89c41c4-a357-489a-90b0-df5c98d3ba32}, !- Handle
+ {74bc0cd9-a986-4138-923d-027c806a0263}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {c61f6f5d-46d7-4634-bf2a-842af9541399}, !- Handle
+ {1f0b51b8-7abe-4639-b9a5-4f45444fee76}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {1a9ca66e-2c27-463c-8ab9-5a072ff5ca38}, !- Handle
+ {dd31cfb0-cf9a-4789-9046-087f5fa08062}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {86507548-b091-444e-9e83-140677a4becf}, !- Handle
+ {d56413b2-72a4-4199-9e4b-c3a461d3c0f9}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {7aedbb2d-56b3-4eb0-9681-504a4b06b52c}, !- Handle
+ {47452380-ba0e-4f6f-a321-392aced50aaa}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {60b72525-7676-4f5a-bec2-1f905087875a}, !- Handle
+ {eae4043c-3774-4b34-af5b-055f7694aa71}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {c59b3119-26c2-4a05-8734-39c4872aa144}, !- Handle
+ {46469dab-3c42-4ac1-922f-e14e0e857773}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {95c5ed8c-0100-47ca-8ae5-7cae5670b085}, !- Handle
+ {60e078db-69c1-4c10-ac14-391cd58d2bfc}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {78a3920d-562a-46f8-8e1e-e0bcbe345adc}, !- Handle
+ {654db37a-9f7b-477a-a04e-0e724d82c11a}; !- Material Name
+
+OS:StandardsInformation:Construction,
+ {c48e4cf8-9dd8-4bf3-8d56-7ae6448324eb}, !- Handle
+ {b867469e-c77d-44f6-9002-a0d91c146056}; !- Construction Name
+
+OS:StandardsInformation:Material,
+ {fd5dc0ba-9d16-4d8e-988d-b7f1d42e2183}, !- Handle
+ {baed53d3-a22d-4016-be2e-3aef134c0014}; !- Material Name
+
+OS:StandardsInformation:Material,
+ {36cf753e-2ff2-42b0-87cc-c659a56d22ea}, !- Handle
+ {bc3fd780-2282-436d-9581-f5207bda8949}; !- Material Name
+
+OS:StandardsInformation:Construction,
+ {15722992-8bbb-4f97-a240-1abe504fe61b}, !- Handle
+ {0212f535-8a17-48b3-ba4e-b19d59e6fae1}; !- Construction Name
+
diff --git a/measures/utility_bills/measure.rb b/measures/utility_bills/measure.rb
index b6501d3f3..498a8e620 100644
--- a/measures/utility_bills/measure.rb
+++ b/measures/utility_bills/measure.rb
@@ -407,40 +407,43 @@ def run(runner, user_arguments)
runner.registerValue('electricity_bill_number_of_rates', n_bills)
# Natural Gas Bill
+ ng_bill_dollars = 0
if sql.naturalGasTotalEndUses.is_initialized
tot_kbtu = OpenStudio.convert(sql.naturalGasTotalEndUses.get, 'GJ', 'kBtu').get
if tot_kbtu > 0
prices_path = File.join(File.dirname(__FILE__), 'resources', 'eia_com_gas_prices_dol_per_kbtu_2022.json')
dollars_per_kbtu = JSON.parse(File.read(prices_path))[state_abbreviation]
- utility_bill_dollars = (tot_kbtu * dollars_per_kbtu).round.to_i
+ ng_bill_dollars = (tot_kbtu * dollars_per_kbtu).round.to_i
runner.registerValue("natural_gas_rate_name", "EIA 2022 Average Commercial Natural Gas Price for #{state_abbreviation}")
- runner.registerValue("natural_gas_bill_dollars", utility_bill_dollars)
end
end
+ runner.registerValue("natural_gas_bill_dollars", ng_bill_dollars)
# Propane Bill
+ propane_bill_dollars = 0
if sql.propaneTotalEndUses.is_initialized
tot_kbtu = OpenStudio.convert(sql.propaneTotalEndUses.get, 'GJ', 'kBtu').get
if tot_kbtu > 0
prices_path = File.join(File.dirname(__FILE__), 'resources', 'eia_res_propane_prices_dol_per_kbtu_2022.json')
dollars_per_kbtu = JSON.parse(File.read(prices_path))[state_abbreviation]
- utility_bill_dollars = (tot_kbtu * dollars_per_kbtu).round.to_i
+ propane_bill_dollars = (tot_kbtu * dollars_per_kbtu).round.to_i
runner.registerValue("propane_rate_name", "EIA 2022 Average Residential Propane Price for #{state_abbreviation}")
- runner.registerValue("propane_bill_dollars", utility_bill_dollars)
end
end
+ runner.registerValue("propane_bill_dollars", propane_bill_dollars)
# Fuel Oil Bill
+ fo_bill_dollars = 0
if sql.fuelOilNo2TotalEndUses.is_initialized
tot_kbtu = OpenStudio.convert(sql.fuelOilNo2TotalEndUses.get, 'GJ', 'kBtu').get
if tot_kbtu > 0
prices_path = File.join(File.dirname(__FILE__), 'resources', 'eia_res_fuel_oil_prices_dol_per_kbtu_2022.json')
dollars_per_kbtu = JSON.parse(File.read(prices_path))[state_abbreviation]
- utility_bill_dollars = (tot_kbtu * dollars_per_kbtu).round.to_i
+ fo_bill_dollars = (tot_kbtu * dollars_per_kbtu).round.to_i
runner.registerValue("fuel_oil_rate_name", "EIA 2022 Average Residential Fuel Oil Price for #{state_abbreviation}")
- runner.registerValue("fuel_oil_bill_dollars", utility_bill_dollars)
end
end
+ runner.registerValue("fuel_oil_bill_dollars", fo_bill_dollars)
# District Heating Bills
# TODO have not found any source of rates beyond data for individual utilities
diff --git a/measures/utility_bills/measure.xml b/measures/utility_bills/measure.xml
index 3ca509054..6ca7352b9 100644
--- a/measures/utility_bills/measure.xml
+++ b/measures/utility_bills/measure.xml
@@ -3,8 +3,8 @@
3.1
utility_bills
2a3442c1-944d-4e91-9e11-11e0cf368c64
- 3835ce49-df43-471c-8439-6bb22b89f8a5
- 2024-06-20T19:00:14Z
+ fb2cbc7a-9ce7-4b09-9253-fb7777fd62c5
+ 2024-10-14T14:44:11Z
15BF4E57
UtilityBills
Utility Bills
@@ -33,7 +33,7 @@
measure.rb
rb
script
- C5A9C741
+ FCA5245A
calc_elec_bill.py
diff --git a/postprocessing/comstockpostproc/resources/comstock_column_definitions.csv b/postprocessing/comstockpostproc/resources/comstock_column_definitions.csv
index 277d4e3cf..52a7c6e7d 100644
--- a/postprocessing/comstockpostproc/resources/comstock_column_definitions.csv
+++ b/postprocessing/comstockpostproc/resources/comstock_column_definitions.csv
@@ -643,282 +643,285 @@ results.csv,com_stock_sensitivity_reports.com_report_smallest_space_m_2,out.para
results.csv,com_stock_sensitivity_reports.com_report_number_of_surfaces,out.params.number_of_surfaces,TRUE,FALSE,integer,,,Number of Surface objects in the building energy model
results.csv,completed_at,,FALSE,FALSE,float,,,Simulation end time for model
results.csv,completed_status,completed_status,TRUE,FALSE,string,,,Simulation completion status
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_95_decarb_by_2035_15 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_95_decarb_by_2035_15 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_95_decarb_by_2035_15 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_95_decarb_by_2035_30 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_95_decarb_by_2050_15 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_95_decarb_by_2050_30 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_high_re_cost_15 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_high_re_cost_30 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_low_re_cost_15 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_low_re_cost_15 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_low_re_cost_15 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_low_re_cost_30 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_mid_case_30 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_mid_case_15 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_mid_case_30 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity use, using Cambium 2022 lrmer_mid_case_30 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.cooling.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 aer_95_decarb_by_2035non-levelized values from 2023non-levelized values from 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.cooling.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.cooling.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.cooling.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.cooling.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.cooling.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.cooling.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.cooling.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.cooling.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.cooling.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.cooling.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.cooling.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.cooling.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.cooling.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.cooling.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.cooling.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.cooling.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.cooling.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_cooling_hvac_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.cooling.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the cooling end use, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.exterior_lighting.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.exterior_lighting.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.exterior_lighting.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.exterior_lighting.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.exterior_lighting.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.exterior_lighting.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.exterior_lighting.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.exterior_lighting.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.exterior_lighting.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.exterior_lighting.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.exterior_lighting.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.exterior_lighting.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.exterior_lighting.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.exterior_lighting.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.exterior_lighting.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.exterior_lighting.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.exterior_lighting.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.exterior_lighting.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.exterior_lighting.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.exterior_lighting.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.exterior_lighting.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.exterior_lighting.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.exterior_lighting.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.exterior_lighting.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.exterior_lighting.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.exterior_lighting.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.exterior_lighting.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.exterior_lighting.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.exterior_lighting.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the exterior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.heating.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.heating.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.heating.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.heating.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.heating.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.heating.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.heating.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.heating.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.heating.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.heating.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.heating.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.heating.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.heating.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.heating.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.heating.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.heating.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.heating.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.heating.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.heating.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.heating.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.heating.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.heating.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.heating.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the heating end use, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.interior_equipment.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.interior_equipment.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.interior_equipment.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.interior_equipment.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.interior_equipment.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.interior_equipment.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.interior_equipment.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.interior_equipment.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.interior_equipment.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.interior_equipment.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.interior_equipment.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_equipment end use, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_equipment_fuel_oil_ghg_emissions_kg,out.emissions.electricity.interior_equipment_fuel_oil_ghg_emissions,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the interior_equipment_fuel_oil_ghg_emissions
-results.csv,emissions_reporting.annual_interior_equipment_natural_gas_ghg_emissions_kg,out.emissions.electricity.interior_equipment_natural_gas_ghg_emissions,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the interior_equipment_natural_gas_ghg_emissions
-results.csv,emissions_reporting.annual_interior_equipment_propane_ghg_emissions_kg,out.emissions.electricity.interior_equipment_propane_ghg_emissions,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the interior_equipment_propane_ghg_emissions
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.interior_lighting.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.interior_lighting.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.interior_lighting.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.interior_lighting.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.interior_lighting.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.interior_lighting.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.interior_lighting.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.interior_lighting.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.interior_lighting.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.interior_lighting.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.interior_lighting.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.interior_lighting.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.interior_lighting.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.interior_lighting.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.interior_lighting.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.interior_lighting.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.interior_lighting.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.interior_lighting.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.interior_lighting.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.interior_lighting.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.interior_lighting.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.interior_lighting.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.interior_lighting.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.interior_lighting.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.interior_lighting.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.interior_lighting.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.interior_lighting.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.interior_lighting.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.interior_lighting.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the interior_lighting end use, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.refrigeration.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.refrigeration.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.refrigeration.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.refrigeration.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.refrigeration.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.refrigeration.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.refrigeration.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.refrigeration.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.refrigeration.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.refrigeration.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.refrigeration.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.refrigeration.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.refrigeration.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.refrigeration.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.refrigeration.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the refrigeration end use, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.enduse_group.hvac.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.enduse_group.hvac.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.enduse_group.hvac.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.enduse_group.hvac.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.enduse_group.hvac.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the hvac enduse group, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.water_systems.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 aer_95_decarb_by_2035 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.water_systems.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 aer_95_decarb_by_2050 non-levelized values from 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.water_systems.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 aer_high_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.water_systems.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 aer_low_re_cost non-levelized values from 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.water_systems.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 aer_mid_case non-levelized values from 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.water_systems.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2018 state emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.water_systems.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2018 subregion emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.water_systems.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2019 state emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.water_systems.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2019 subregion emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.water_systems.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2020 state emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.water_systems.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2020 subregion emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.water_systems.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2021 state emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.water_systems.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using egrid 2021 subregion emissions intensity"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_95_decarb_by_2035 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_95_decarb_by_2050 levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.water_systems.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_high_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.water_systems.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_high_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_low_re_cost levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_low_re_cost levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_low_re_cost levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.water_systems.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2025"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.water_systems.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_mid_case levelized over 15 years starting in 2023"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.water_systems.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_mid_case levelized over 25 years starting in 2025"
-results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.water_systems.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,"annual greenhouse gas emissions from electricity for the water_systems end use, using Cambium 2022 lrmer_mid_case levelized over 30 years starting in 2023"
-results.csv,emissions_reporting.annual_natural_gas_ghg_emissions_kg,out.emissions.natural_gas,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on site natural gas use
-results.csv,emissions_reporting.annual_water_systems_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.water_systems,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the water_systems_natural_gas_ghg_emissions
-results.csv,emissions_reporting.annual_total_hvac_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.heating,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the hvac_natural_gas_ghg_emissions
-results.csv,emissions_reporting.annual_heating_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.enduse_group.hvac,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the heating_natural_gas_ghg_emissions
-results.csv,emissions_reporting.annual_propane_ghg_emissions_kg,out.emissions.propane,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on site propane use
-results.csv,emissions_reporting.annual_water_systems_propane_ghg_emissions_kg,out.emissions.propane.water_systems,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the water_systems_propane_ghg_emissions
-results.csv,emissions_reporting.annual_heating_propane_ghg_emissions_kg,out.emissions.propane.enduse_group.hvac,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the heating_propane_ghg_emissions
-results.csv,emissions_reporting.annual_total_hvac_propane_ghg_emissions_kg,out.emissions.propane.heating,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the hvac_propane_ghg_emissions
-results.csv,emissions_reporting.annual_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on site fuel oil use
-results.csv,emissions_reporting.annual_water_systems_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.water_systems,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the water_systems_fuel_oil_ghg_emissions
-results.csv,emissions_reporting.annual_total_hvac_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.heating,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the hvac_fuel_oil_ghg_emissions
-results.csv,emissions_reporting.annual_heating_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.enduse_group.hvac,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from electricity for the heating_fuel_oil_ghg_emissions
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.cooling.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.cooling.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.cooling.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.cooling.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.cooling.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.cooling.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.cooling.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.cooling.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.cooling.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.cooling.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.cooling.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.cooling.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.cooling.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.cooling.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.cooling.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.cooling.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.cooling.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.cooling.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.cooling.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.cooling.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_cooling_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.cooling.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_cooling_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.cooling,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling fuel oil use
+results.csv,emissions_reporting.annual_cooling_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.cooling,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling natural gas use
+results.csv,emissions_reporting.annual_cooling_propane_ghg_emissions_kg,out.emissions.propane.cooling,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site cooling propane use
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site electricity use using Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.exterior_lights.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.exterior_lights.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.exterior_lights.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.exterior_lights.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.exterior_lights.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.exterior_lights.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.exterior_lights.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.exterior_lights.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.exterior_lights.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.exterior_lights.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.exterior_lights.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.exterior_lights.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.exterior_lights.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.exterior_lights.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.exterior_lights.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.exterior_lights.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.exterior_lights.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.exterior_lights.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.exterior_lights.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.exterior_lights.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.exterior_lights.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.exterior_lights.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.exterior_lights.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.exterior_lights.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.exterior_lights.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.exterior_lights.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.exterior_lights.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.exterior_lights.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_exterior_lights_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.exterior_lights.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site exterior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site fuel oil use
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.heating.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.heating.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.heating.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.heating.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.heating.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.heating.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.heating.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.heating.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.heating.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.heating.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.heating.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.heating.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.heating.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.heating.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.heating.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.heating.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.heating.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.heating.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.heating.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.heating.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.heating.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.heating.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.heating.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_heating_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.heating.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_heating_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.heating,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating fuel oil use
+results.csv,emissions_reporting.annual_heating_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.heating,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating natural gas use
+results.csv,emissions_reporting.annual_heating_propane_ghg_emissions_kg,out.emissions.propane.heating,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site heating propane use
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.interior_equipment.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.interior_equipment.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.interior_equipment.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.interior_equipment.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.interior_equipment.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.interior_equipment.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.interior_equipment.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.interior_equipment.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.interior_equipment.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.interior_equipment.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.interior_equipment.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.interior_equipment.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.interior_equipment.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.interior_equipment.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_interior_equipment_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.interior_equipment.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_equipment_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.interior_equipment,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment fuel oil use
+results.csv,emissions_reporting.annual_interior_equipment_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.interior_equipment,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment natural gas use
+results.csv,emissions_reporting.annual_interior_equipment_propane_ghg_emissions_kg,out.emissions.propane.interior_equipment,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior equipment propane use
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.interior_lights.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.interior_lights.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.interior_lights.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.interior_lights.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.interior_lights.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.interior_lights.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.interior_lights.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.interior_lights.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.interior_lights.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.interior_lights.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.interior_lights.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.interior_lights.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.interior_lights.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.interior_lights.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.interior_lights.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.interior_lights.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.interior_lights.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.interior_lights.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.interior_lights.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.interior_lights.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.interior_lights.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.interior_lights.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.interior_lights.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.interior_lights.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.interior_lights.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.interior_lights.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.interior_lights.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.interior_lights.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_interior_lights_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.interior_lights.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site interior lights electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_natural_gas_ghg_emissions_kg,out.emissions.natural_gas,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site natural gas use
+results.csv,emissions_reporting.annual_propane_ghg_emissions_kg,out.emissions.propane,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from total on-site propane use
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.refrigeration.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.refrigeration.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.refrigeration.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.refrigeration.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.refrigeration.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.refrigeration.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.refrigeration.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.refrigeration.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.refrigeration.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.refrigeration.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.refrigeration.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.refrigeration.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.refrigeration.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.refrigeration.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.refrigeration.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.refrigeration.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.refrigeration.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_refrigeration_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.refrigeration.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site refrigeration electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.enduse_group.hvac.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.enduse_group.hvac.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.enduse_group.hvac.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.enduse_group.hvac.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.enduse_group.hvac.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.enduse_group.hvac.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.enduse_group.hvac.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_total_hvac_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.enduse_group.hvac.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_total_hvac_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.enduse_group.hvac,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac fuel oil use
+results.csv,emissions_reporting.annual_total_hvac_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.enduse_group.hvac,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac natural gas use
+results.csv,emissions_reporting.annual_total_hvac_propane_ghg_emissions_kg,out.emissions.propane.enduse_group.hvac,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site total hvac propane use
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_95_decarb_by_2035_kg,out.emissions.electricity.water_systems.aer_95_decarb_by_2035_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2035 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_95_decarb_by_2050_kg,out.emissions.electricity.water_systems.aer_95_decarb_by_2050_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Average Emissions Rate 95% decarb by 2050 non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_high_re_cost_kg,out.emissions.electricity.water_systems.aer_high_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Average Emissions Rate high renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_low_re_cost_kg,out.emissions.electricity.water_systems.aer_low_re_cost_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Average Emissions Rate low renewable energy cost non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_aer_mid_case_kg,out.emissions.electricity.water_systems.aer_mid_case_from_2023,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Average Emissions Rate mid case non-levelized emissions intensity values from 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2018_state_kg,out.emissions.electricity.water_systems.egrid_2018_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2018 state emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2018_subregion_kg,out.emissions.electricity.water_systems.egrid_2018_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2018 subregion emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2019_state_kg,out.emissions.electricity.water_systems.egrid_2019_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2019 state emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2019_subregion_kg,out.emissions.electricity.water_systems.egrid_2019_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2019 subregion emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2020_state_kg,out.emissions.electricity.water_systems.egrid_2020_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2020 state emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2020_subregion_kg,out.emissions.electricity.water_systems.egrid_2020_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2020 subregion emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2021_state_kg,out.emissions.electricity.water_systems.egrid_2021_state,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2021 state emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_egrid_2021_subregion_kg,out.emissions.electricity.water_systems.egrid_2021_subregion,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with eGRID 2021 subregion emissions intensity values
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_2025_start_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_15_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_25_2025_start_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2035_30_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2035_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2035 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2050_15_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2050_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_95_decarb_by_2050_30_kg,out.emissions.electricity.water_systems.lrmer_95_decarb_by_2050_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate 95% decarb by 2050 emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_high_re_cost_15_kg,out.emissions.electricity.water_systems.lrmer_high_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_high_re_cost_30_kg,out.emissions.electricity.water_systems.lrmer_high_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate high renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_15_2025_start_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_15_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_25_2025_start_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_low_re_cost_30_kg,out.emissions.electricity.water_systems.lrmer_low_re_cost_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate low renewable energy cost emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_15_2025_start_kg,out.emissions.electricity.water_systems.lrmer_mid_case_15_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2025
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_15_kg,out.emissions.electricity.water_systems.lrmer_mid_case_15_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 15 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_25_2025_start_kg,out.emissions.electricity.water_systems.lrmer_mid_case_25_2025_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 25 years starting in 2025
+results.csv,emissions_reporting.annual_water_systems_electricity_ghg_emissions_lrmer_mid_case_30_kg,out.emissions.electricity.water_systems.lrmer_mid_case_30_2023_start,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems electricity use with Cambium 2022 Long-Range Marginal Emissions Rate mid case emissions intensity values levelized over 30 years starting in 2023
+results.csv,emissions_reporting.annual_water_systems_fuel_oil_ghg_emissions_kg,out.emissions.fuel_oil.water_systems,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems fuel oil use
+results.csv,emissions_reporting.annual_water_systems_natural_gas_ghg_emissions_kg,out.emissions.natural_gas.water_systems,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems natural gas use
+results.csv,emissions_reporting.annual_water_systems_propane_ghg_emissions_kg,out.emissions.propane.water_systems,TRUE,FALSE,float,co2e_kg,co2e_kg,annual greenhouse gas emissions from on-site water systems propane use
results.csv,emissions_reporting.applicable,,FALSE,FALSE,boolean,,,
results.csv,emissions_reporting.emissions_scenario,,FALSE,FALSE,string,,,
results.csv,emissions_reporting.grid_region,,FALSE,FALSE,string,,,
diff --git a/sampling/README.md b/sampling/README.md
index 867a6b672..b173f7760 100644
--- a/sampling/README.md
+++ b/sampling/README.md
@@ -18,6 +18,12 @@ This only needs to be done once because it will create a new environment called
$ conda activate comstock-sampling
```
+Install buildstockbatch in comstock-sampling environment: navigate to location of buildstock batch, e.g.:
+```
+$ cd /path/to/buildstockbatch
+$ python -m pip install -e .
+```
+
## AWS Access
### Non-NREL Staff
@@ -73,10 +79,15 @@ There are two types of samples you can generate:
- From this directory, run the following command:
```
- $ python tsv_resampling.py tsv_version sim_year n_samples hvac_sizing
+ $ python tsv_resampling.py tsv_version sim_year n_samples n_buckets hvac_sizing
```
- - Where `tsv_version` is the version of tsv files to sample from (e.g., v16), `sim_year` is the simulation year (2015-2019), `n_samples` is the number of samples you wish to generate -- a typical full national sample is 350,000 samples -- and `hvac_sizing` dictates whether the HVAC systems in the models are autosized or hardsized (use "autosize" or "hardsize" for this argument).
+ - Where:
+ - `tsv_version` is the version of tsv files to sample from (e.g., v99 TODO: Ry to change)
+ - `sim_year` is the simulation year (2015-2019)
+ - `n_samples` is the number of samples you wish to generate. A typical full national sample is 350,000 samples.
+ - 'n_buckets` is 1 (TODO: Ry to explain this)
+ - `hvac_sizing` dictates whether the HVAC systems in the models are autosized or hardsized (use "autosize" or "hardsize" for this argument).
- This will generate a buildstock.csv file and save it to `.\output-buildstocks\intermediate`.
- The name of the file will include the date, tsv version, simulation year, your username, and number of samples. For example: `buildstock_20221020_v17_2018_alebar_500.csv`.
diff --git a/sampling/tsv_resampling.py b/sampling/tsv_resampling.py
index 76fe41b88..03e6510d1 100644
--- a/sampling/tsv_resampling.py
+++ b/sampling/tsv_resampling.py
@@ -334,12 +334,12 @@ def _run_sampling(self, tmp_csv_path, csv_path):
)
if jsons:
- res = Parallel(round(cpu_count()), verbose=5)(
+ res = Parallel(round(cpu_count()), verbose=5, prefer='threads')(
delayed(self._com_execute_json_samples)(
tsv_hash, dependency_hash, attr_order, sample_matrices[bucket], prev_results_list[bucket]
) for bucket in range(self.n_buckets))
else:
- res = Parallel(round(cpu_count()), verbose=5)(
+ res = Parallel(round(cpu_count()), verbose=5, prefer='threads')(
delayed(self._com_execute_samples)(
tsv_hash, dependency_hash, attr_order, sample_matrices[bucket], prev_results_list[bucket]
) for bucket in range(self.n_buckets)