Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

ResStock Args consistency with OS-HPXML #1289

Open
lixiliu opened this issue Aug 21, 2024 · 0 comments · May be fixed by #1312
Open

ResStock Args consistency with OS-HPXML #1289

lixiliu opened this issue Aug 21, 2024 · 0 comments · May be fixed by #1312

Comments

@lixiliu
Copy link
Contributor

lixiliu commented Aug 21, 2024

Compiling a list of inconsistencies between the ResStock Arguments in Options_lookup and OS-HPXML documentation:

  • For Water Heater Efficiency, water_heater_recovery_efficiency=0 for all electric tank options such as "Electric Premium". In OS-HPXML, all electric storage WH has RE=0.98. (Per Joe, RE is intentionally set to 0 to imply not used. IMO, this is a bit confusing as for HPWH, RE is also set to 0 but this time to imply not applicable.)
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

Successfully merging a pull request may close this issue.

1 participant