diff --git a/project_national/national_upgrades_perf_data.yml b/project_national/national_upgrades_perf_data.yml new file mode 100644 index 0000000000..b2732fa7c1 --- /dev/null +++ b/project_national/national_upgrades_perf_data.yml @@ -0,0 +1,140 @@ +schema_version: '0.3' +os_version: 3.7.0 +os_sha: d5269793f1 +buildstock_directory: ../ # Relative to this file or absolute +project_directory: project_national # Relative to buildstock_directory +output_directory: national_upgrades_perf_data +weather_files_url: https://data.nrel.gov/system/files/156/Buildstock_TMY3_FIPS-1678817889.zip +# weather_files_path: c:/OpenStudio/BuildStock_TMY3_FIPS.zip + +sampler: + type: residential_quota + args: + n_datapoints: 5 + +workflow_generator: + type: residential_hpxml + args: + build_existing_model: + simulation_control_timestep: 60 + simulation_control_run_period_begin_month: 1 + simulation_control_run_period_begin_day_of_month: 1 + simulation_control_run_period_end_month: 12 + simulation_control_run_period_end_day_of_month: 31 + simulation_control_run_period_calendar_year: 2007 + + emissions: + - scenario_name: LRMER_MidCase_15 + type: CO2e + elec_folder: data/emissions/cambium/2022/LRMER_MidCase_15 + + utility_bills: + - scenario_name: Bills + + simulation_output_report: + timeseries_frequency: hourly + include_timeseries_total_consumptions: true + include_timeseries_fuel_consumptions: true + include_timeseries_end_use_consumptions: true + include_timeseries_emissions: true + include_timeseries_emission_fuels: true + include_timeseries_emission_end_uses: true + include_timeseries_hot_water_uses: true + include_timeseries_total_loads: true + include_timeseries_component_loads: true + include_timeseries_unmet_hours: true + include_timeseries_zone_temperatures: true + include_timeseries_airflows: true + include_timeseries_weather: true + include_timeseries_resilience: true + + reporting_measures: + - measure_dir_name: QOIReport + + server_directory_cleanup: + retain_in_idf: false + retain_schedules_csv: false + +baseline: + n_buildings_represented: 139647020 # American Community Survey 2021 5-year, B25001, does not include territories ( 138765649 without AK and HI ) + +upgrades: + - upgrade_name: ASHP Default + package_apply_logic: + - HVAC Has Ducts|Yes + options: + - &hvac_heating_efficiency_ashp_seer_22_10_hspf + option: HVAC Heating Efficiency|ASHP, SEER 22, 10 HSPF + costs: + - value: 50.0 + multiplier: Size, Heating System Primary (kBtu/h) + lifetime: 30 + - &hvac_cooling_efficiency_ducted_heat_pump + option: HVAC Cooling Efficiency|Ducted Heat Pump + - &heat_pump_backup_use_existing_system + option: Heat Pump Backup|Use Existing System + - &hvac_detailed_performance_data_default + option: HVAC Detailed Performance Data|Default + + - upgrade_name: ASHP Heating Reference + package_apply_logic: + - HVAC Has Ducts|Yes + options: + - *hvac_heating_efficiency_ashp_seer_22_10_hspf + - *hvac_cooling_efficiency_ducted_heat_pump + - *heat_pump_backup_use_existing_system + - &hvac_detailed_performance_data_heating_reference + option: HVAC Detailed Performance Data|Heating Reference + + - upgrade_name: ASHP Heating 10 HSPF + package_apply_logic: + - HVAC Has Ducts|Yes + options: + - *hvac_heating_efficiency_ashp_seer_22_10_hspf + - *hvac_cooling_efficiency_ducted_heat_pump + - *heat_pump_backup_use_existing_system + - &hvac_detailed_performance_data_heating_10_hspf + option: HVAC Detailed Performance Data|Heating 10 HSPF + + - upgrade_name: MSHP Default + package_apply_logic: + - HVAC Has Ducts|No + options: + - &hvac_heating_efficiency_mshp_seer_25_12_pt_7_hspf + option: HVAC Heating Efficiency|MSHP, SEER 25, 12.7 HSPF + costs: + - value: 50.0 + multiplier: Size, Heating System Primary (kBtu/h) + lifetime: 30 + - &hvac_cooling_efficiency_non_ducted_heat_pump + option: HVAC Cooling Efficiency|Non-Ducted Heat Pump + - *heat_pump_backup_use_existing_system + - *hvac_detailed_performance_data_default + + - upgrade_name: MSHP Heating Reference + package_apply_logic: + - HVAC Has Ducts|No + options: + - *hvac_heating_efficiency_ashp_seer_22_10_hspf + - *hvac_cooling_efficiency_non_ducted_heat_pump + - *heat_pump_backup_use_existing_system + - *hvac_detailed_performance_data_heating_reference + + - upgrade_name: MSHP Heating 10 HSPF + package_apply_logic: + - HVAC Has Ducts|No + options: + - *hvac_heating_efficiency_ashp_seer_22_10_hspf + - *hvac_cooling_efficiency_non_ducted_heat_pump + - *heat_pump_backup_use_existing_system + - *hvac_detailed_performance_data_heating_10_hspf + +eagle: + n_jobs: 3 + minutes_per_sim: 5 + account: + postprocessing: + time: 20 + n_workers: 1 + sampling: + time: 10 diff --git a/resources/options_lookup.tsv b/resources/options_lookup.tsv index 25191279f7..972476a9bb 100644 --- a/resources/options_lookup.tsv +++ b/resources/options_lookup.tsv @@ -9675,6 +9675,8 @@ HVAC Cooling Type Non-Ducted Heat Pump HVAC Cooling Type None HVAC Cooling Type Room AC HVAC Detailed Performance Data Default ResStockArguments hvac_perf_data_capacity_type=auto hvac_perf_data_heating_outdoor_temperatures=auto hvac_perf_data_heating_min_speed_capacities=auto hvac_perf_data_heating_max_speed_capacities=auto hvac_perf_data_heating_min_speed_cops=auto hvac_perf_data_heating_max_speed_cops=auto hvac_perf_data_cooling_outdoor_temperatures=auto hvac_perf_data_cooling_min_speed_capacities=auto hvac_perf_data_cooling_max_speed_capacities=auto hvac_perf_data_cooling_min_speed_cops=auto hvac_perf_data_cooling_max_speed_cops=auto +HVAC Detailed Performance Data Heating 10 HSPF ResStockArguments hvac_perf_data_capacity_type=Normalized capacity fractions hvac_perf_data_heating_outdoor_temperatures=47.0, 17.0, 5.0, -15.0 hvac_perf_data_heating_min_speed_capacities=0.314, 0.338, 0.347, 0.363 hvac_perf_data_heating_max_speed_capacities=1.029, 0.750, 0.638, 0.452 hvac_perf_data_heating_min_speed_cops=4.370, 2.810, 2.190, 1.157 hvac_perf_data_heating_max_speed_cops=3.54, 2.50, 2.08, 1.38 hvac_perf_data_cooling_outdoor_temperatures=auto hvac_perf_data_cooling_min_speed_capacities=auto hvac_perf_data_cooling_max_speed_capacities=auto hvac_perf_data_cooling_min_speed_cops=auto hvac_perf_data_cooling_max_speed_cops=auto +HVAC Detailed Performance Data Heating Reference ResStockArguments hvac_perf_data_capacity_type=Normalized capacity fractions hvac_perf_data_heating_outdoor_temperatures=47.0, 17.0, 5.0, -15.0 hvac_perf_data_heating_min_speed_capacities=0.310, 0.374, 0.392, 0.272 hvac_perf_data_heating_max_speed_capacities=1.030, 0.759, 0.679, 0.479 hvac_perf_data_heating_min_speed_cops=4.42, 2.57, 2.06, 1.66 hvac_perf_data_heating_max_speed_cops=3.38, 2.33, 1.99, 1.49 hvac_perf_data_cooling_outdoor_temperatures=auto hvac_perf_data_cooling_min_speed_capacities=auto hvac_perf_data_cooling_max_speed_capacities=auto hvac_perf_data_cooling_min_speed_cops=auto hvac_perf_data_cooling_max_speed_cops=auto HVAC Has Ducts No HVAC Has Ducts Void HVAC Has Ducts Yes @@ -9697,7 +9699,7 @@ HVAC Heating Efficiency "ASHP, SEER 15, 9.0 HSPF" ResStockArguments heating_syst HVAC Heating Efficiency "ASHP, SEER 16, 9.0 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=air-to-air heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=9.0 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=16 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=auto heat_pump_heating_capacity_retention_temp=auto heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "ASHP, SEER 17, 8.7 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=air-to-air heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=8.7 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=17 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=auto heat_pump_heating_capacity_retention_temp=auto heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "ASHP, SEER 18, 9.3 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=air-to-air heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=9.3 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=18 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=auto heat_pump_heating_capacity_retention_temp=auto heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto -HVAC Heating Efficiency "ASHP, SEER 22, 10 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=air-to-air heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=10 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=22 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=auto heat_pump_heating_capacity_retention_temp=auto heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto +HVAC Heating Efficiency "ASHP, SEER 22, 10 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=air-to-air heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=10 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=22 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=auto heat_pump_heating_capacity_retention_temp=auto heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=variable speed heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "Dual-Fuel ASHP, SEER 14, 8.2 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=air-to-air heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=8.2 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=14 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=natural gas heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=auto heat_pump_heating_capacity_retention_temp=auto heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "Electric Baseboard, 100% Efficiency" ResStockArguments heating_system_type=ElectricResistance heating_system_heating_efficiency=1 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=none heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=0 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=none heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "Electric Boiler, 100% AFUE" ResStockArguments heating_system_type=Boiler heating_system_heating_efficiency=1 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=none heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=0 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=none heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto @@ -9730,7 +9732,7 @@ HVAC Heating Efficiency "MSHP, SEER 17, 9.5 HSPF" ResStockArguments heating_syst HVAC Heating Efficiency "MSHP, SEER 17, 9.5 HSPF, Ducted" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=9.5 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=17.0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.25 heat_pump_heating_capacity_retention_temp=-5 heat_pump_is_ducted=true heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "MSHP, SEER 18.0, 9.6 HSPF, 60% Conditioned" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=9.6 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=18.0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=0.6 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=0.6 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.25 heat_pump_heating_capacity_retention_temp=-5 heat_pump_is_ducted=false heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "MSHP, SEER 18.0, 9.6 HSPF, 60% Conditioned, Ducted" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=9.6 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=18.0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=0.6 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=0.6 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.25 heat_pump_heating_capacity_retention_temp=-5 heat_pump_is_ducted=true heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto -HVAC Heating Efficiency "MSHP, SEER 25, 12.7 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=12.7 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=25.0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.5 heat_pump_heating_capacity_retention_temp=-15 heat_pump_is_ducted=false heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto +HVAC Heating Efficiency "MSHP, SEER 25, 12.7 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=12.7 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=25.0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.5 heat_pump_heating_capacity_retention_temp=-15 heat_pump_is_ducted=false heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=variable speed heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "MSHP, SEER 25, 12.7 HSPF, Ducted" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=12.7 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=25.0 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.5 heat_pump_heating_capacity_retention_temp=-15 heat_pump_is_ducted=true heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "MSHP, SEER 29.3, 14 HSPF" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=14 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=29.3 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.5 heat_pump_heating_capacity_retention_temp=-15 heat_pump_is_ducted=false heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto HVAC Heating Efficiency "MSHP, SEER 29.3, 14 HSPF, Ducted" ResStockArguments heating_system_type=none heating_system_heating_efficiency=0 heating_system_heating_capacity=auto heating_system_fraction_heat_load_served=1 heating_system_has_flue_or_chimney=auto heat_pump_type=mini-split heat_pump_heating_efficiency_type=HSPF heat_pump_heating_efficiency=14 heat_pump_cooling_efficiency_type=SEER heat_pump_cooling_efficiency=29.3 heat_pump_sizing_methodology=ACCA heat_pump_heating_capacity=auto heat_pump_fraction_heat_load_served=1 heat_pump_cooling_capacity=auto heat_pump_fraction_cool_load_served=1 heat_pump_backup_type=integrated heat_pump_backup_fuel=electricity heat_pump_backup_heating_efficiency=1 heat_pump_backup_heating_capacity=auto heat_pump_heating_capacity_retention_fraction=0.5 heat_pump_heating_capacity_retention_temp=-15 heat_pump_is_ducted=true heat_pump_backup_heating_lockout_temp=auto heat_pump_compressor_lockout_temp=auto heat_pump_cooling_compressor_type=auto heat_pump_cooling_sensible_heat_fraction=auto heat_pump_crankcase_heater_watts=auto geothermal_loop_configuration=none geothermal_loop_borefield_configuration=auto geothermal_loop_loop_flow=auto geothermal_loop_boreholes_count=auto geothermal_loop_boreholes_length=auto geothermal_loop_boreholes_spacing=auto geothermal_loop_boreholes_diameter=auto geothermal_loop_grout_type=auto geothermal_loop_pipe_type=auto geothermal_loop_pipe_diameter=auto