Case Name | Case Desciption | Base Model | Test Type |
Flow Support |
Comments |
---|---|---|---|---|---|
ACTIONW-WPIMULT-00 | Base case run, with producers OP01 to OP04 having ACTIONW blocks that applies a PI multiplier 1.00. | WPIMULT | NO | Waiting on OPM Flow implementation. | |
ACTIONW-WPIMULT-01 | Producers OP01 to OP04 have an ACTIONW blocks that reduces the PI of the well by 0.900. | WPIMULT | NO | Waiting on OPM Flow implementation. | |
ACTIONW-WPIMULT-02 | Various ACTIONW blocks to test behaviour, including nested ACTIONW block (see below). | WPIMULT | NO | Waiting on OPM Flow implementation. | |
ACTIONW-WPIMULT-03 | Various ACTIONW blocks to test behaviour on both producers and injectors (see below). | WPIMULT | NO | Waiting on OPM Flow implementation. | |
ACTIONW-WPIMULT-04 | Various ACTIONW blocks to test behaviour on both producers and injectors (see below). | WPIMULT | NO | Waiting on OPM Flow implementation. | |
ACTIONW-WPIMULT-05 | Various ACTIONW blocks with oil producers productivity indices modified to give more variable results (see below). | WPIMULT | NA | Waiting on OPM Flow implementation. |
The ACTIONW keyword is currently not supported, but work is ongoing to implement the keyword; thus, these tests are designed to test the implementation when the keyword has been implemented.
Notes:
- Test Type column shows if the case is used for integration testing (Int), or regression testing (Reg).
- All models run on five day time steps via the TUNNING keyword.
Version: 25 November 2022
This model is a simple (9, 9, 2) model with five oil producers and four water injectors using an Irregular Corner-Point grid. This is a three-phase model using MODEL05 PVT and well VFP data. The model has only one group, as shown below:
FIELD
|
|---PLAT-1
Base case model with:
- The field has an oil rate target of 10,000 m3/d and water injection is via PLAT-1 is set VREP 1.00.
- Base case run with producers OP01 to OP04 having ACTIONW blocks that applies a PI multiplier of 1.00 when the water cut exceeds, 0.20, 0.40 and 0.60. Used for testing the timing of the ACTIONW events, as the run should not change anything.
- The field has an oil rate target of 10,000 m3/d and water injection is via PLAT-1 is set VREP 1.00.
- Producers OP01 to OP04 have ACTIONW blocks that multiplies the PI of the well by 0.900 when the water cut exceeds, 0.20, 0.40 and 0.60.
- The field has an oil rate target of 10,000 m3/d and water injection is via PLAT-1 is set VREP 1.00.
- Producer OP01 has a nested ACTIONW block that first tests if the well's water cut exceeds 0.20 (ACTW-01A), if it does then ACTW-01B checks if the well PI is greater than 40.0 and if it is, then multiply the PI by 0.900. ACTW-01A is set to execute three times and ACTW-01B only once, so the action should only be executed once.
- For OP02 the ACTW-02A and ACTW-02B are the same as for OP01, except ACTW-02B is allowed to execute twice.
- OP03 is the same as OP01, except this should not execute as the ACTW-03A and ACTW-03B should be overwritten by OP04 action blocks.
- OP04 is the same as OP01, except this should execute as the ACTW-03A and ACTW-03B overwrite the previous versions, and thus OP04 is choked back but not OP03. This is a deliberate typo test to check if we issue a warning if this occurs.
- The field has an oil rate target of 10,000 m3/d and water injection is via PLAT-1 is set VREP 1.00.
- Producer OP01 has an ACTIONW block that tests if the well's total liquid production is greater than 2.10E6 (ACTW-01), if it is then the well PI is increased by 1.100. ACTW-01 is set to execute three times.
- OP02 has a ACTIONXW block with ACTW-02 checking if the well's total liquid production is greater than 1.56E6, and if is then the PI is reduced by 0.900, three times.
- ACTI-03 checks if the water injection total for WI03 is greater than 3.0E6 four times, and if it is, then the PI is reduced.
- Finally, ACTI-04 checks if the water injection total for WI04 is greater than 3.2E6 four times, and if it is then the PI is increased four times.
- The field has an oil rate target of 10,000 m3/d and water injection is via PLAT-1 is set VREP 1.00.
- Producer OP01 has an ACTIONW block that tests if the well's total liquid production is greater than 2.10E6 (ACTW-01), if it is then the well PI is increased by 1.100. ACTW-01 is set to execute three times.
- OP02 has a nested ACTIONXW with ACTW-02A checking if the well's total liquid production is greater than 1.56E6, and if is then ACTW-02B decreases the PI by 0.900. ACTW02A and ACTW-02B are allowed to execute three times.
- ACTI-03A checks if the water injection total for WI03 is greater than 3.0E6 one time, and if it is, then ACTI-03B is called four times to reduce the PI.
- Finally, ACTI-04A checks if the water injection total for WI04 is greater than 3.2E6 two times, and if it is then ACTI-04B called four times to reduce the PI.
- The field has an oil rate target of 10,000 m3/d and water injection is via PLAT-1 is set VREP 1.00.
- Oil producers productivity indices modified to give more variable results.
- ACT-01 checks all wells to see if their water cut is above a certain value, and if so shuts in layer two.