-
Notifications
You must be signed in to change notification settings - Fork 0
/
Template_ESXi_HP_Smart_Array.xml
140 lines (140 loc) · 5.85 KB
/
Template_ESXi_HP_Smart_Array.xml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
<?xml version="1.0" encoding="UTF-8"?>
<zabbix_export>
<version>3.2</version>
<date>2019-06-06T11:00:03Z</date>
<groups>
<group>
<name>Templates</name>
</group>
</groups>
<templates>
<template>
<template>Template ESXi HP Smart Array</template>
<name>Template ESXi HP Smart Array</name>
<description/>
<groups>
<group>
<name>Templates</name>
</group>
</groups>
<applications>
<application>
<name>HP Smart Array</name>
</application>
</applications>
<items/>
<discovery_rules>
<discovery_rule>
<name>Discovery HP Smart Array</name>
<type>0</type>
<snmp_community/>
<snmp_oid/>
<key>hpssacli.discovery</key>
<delay>3600</delay>
<status>0</status>
<allowed_hosts/>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<delay_flex/>
<params/>
<ipmi_sensor/>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port/>
<filter>
<evaltype>0</evaltype>
<formula/>
<conditions>
<condition>
<macro>{#PHYSICALDRIVE}</macro>
<value>^[0-9]</value>
<operator>8</operator>
<formulaid>A</formulaid>
</condition>
</conditions>
</filter>
<lifetime>14</lifetime>
<description/>
<item_prototypes>
<item_prototype>
<name>HP Smart Array Disk {#PHYSICALDRIVE}</name>
<type>0</type>
<snmp_community/>
<multiplier>0</multiplier>
<snmp_oid/>
<key>hpssacli.status[{#PHYSICALDRIVE}]</key>
<delay>3600</delay>
<history>30</history>
<trends>0</trends>
<status>0</status>
<value_type>4</value_type>
<allowed_hosts/>
<units/>
<delta>0</delta>
<snmpv3_contextname/>
<snmpv3_securityname/>
<snmpv3_securitylevel>0</snmpv3_securitylevel>
<snmpv3_authprotocol>0</snmpv3_authprotocol>
<snmpv3_authpassphrase/>
<snmpv3_privprotocol>0</snmpv3_privprotocol>
<snmpv3_privpassphrase/>
<formula>1</formula>
<delay_flex/>
<params/>
<ipmi_sensor/>
<data_type>0</data_type>
<authtype>0</authtype>
<username/>
<password/>
<publickey/>
<privatekey/>
<port/>
<description>The status of physical drive in smart array</description>
<inventory_link>0</inventory_link>
<applications>
<application>
<name>HP Smart Array</name>
</application>
</applications>
<valuemap/>
<logtimefmt/>
<application_prototypes/>
</item_prototype>
</item_prototypes>
<trigger_prototypes>
<trigger_prototype>
<expression>{Template ESXi HP Smart Array:hpssacli.status[{#PHYSICALDRIVE}].str("OK)",#3)}<>1</expression>
<recovery_mode>0</recovery_mode>
<recovery_expression/>
<name>HP Smart Array Physical disk {#PHYSICALDRIVE} failure</name>
<correlation_mode>0</correlation_mode>
<correlation_tag/>
<url/>
<status>0</status>
<priority>5</priority>
<description/>
<type>0</type>
<manual_close>0</manual_close>
<dependencies/>
<tags/>
</trigger_prototype>
</trigger_prototypes>
<graph_prototypes/>
<host_prototypes/>
</discovery_rule>
</discovery_rules>
<httptests/>
<macros/>
<templates/>
<screens/>
</template>
</templates>
</zabbix_export>