Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathsystem_set.py
380 lines (327 loc) · 12.2 KB
/
system_set.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
# -*- coding: utf-8 -*-
"""
Module implementing sys_set_ui.
"""
import sys
import time
import PyQt4
from PyQt4.QtGui import QDialog
from PyQt4.QtCore import pyqtSignature, QTimer, SIGNAL
from Ui_system_set import Ui_sys_set_ui
from init_op import read_config,write_config
from qmdz_const import SYS_CONF_PATH,PARA_NAME,PARA_DEFAULT
from INST.AI518P import ai518p_api
from INST.HMT_S48 import C_S48,REG_DICT
from INST.INST2400 import Keithley2400
from INST.valve_ctrl import Valve_Ctrl
flow_index = {'50':0,'500':1,'2000':2}
class sys_set_ui(QDialog, Ui_sys_set_ui):
"""
Class documentation goes here.
"""
def __init__(self, parent = None):
"""
Constructor
"""
QDialog.__init__(self, parent)
self.setupUi(self)
self.read_conf()
self.xtime = 0
self.timer = QTimer(self)
self.connect(self.timer,SIGNAL("timeout()"),self.measure)
@pyqtSignature("QString")
def on_com_518p_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'AI518P', 'port', str(p0))
@pyqtSignature("QString")
def on_baud_518p_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'AI518P', 'baud', str(p0))
@pyqtSignature("QString")
def on_com_flowmeter_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
self.s48_port = str(p0)
write_config(SYS_CONF_PATH, 'HMTS48', 'port', str(p0))
@pyqtSignature("QString")
def on_baud_flowmeter_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'HMTS48', 'baud', str(p0))
@pyqtSignature("QString")
def on_range1_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'HMTS48', 'flow1_range', str(p0))
@pyqtSignature("QString")
def on_range2_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'HMTS48', 'flow2_range', str(p0))
@pyqtSignature("QString")
def on_range3_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'HMTS48', 'flow3_range', str(p0))
@pyqtSignature("QString")
def on_com_pcb_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'PCB', 'port', str(p0))
Valve_Ctrl.close()
Valve_Ctrl.connect(str(p0))
@pyqtSignature("QString")
def on_baud_pcb_currentIndexChanged(self, p0):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
write_config(SYS_CONF_PATH, 'PCB', 'baud', str(p0))
@pyqtSignature("int")
def on_pcb_ctrl_obj_currentIndexChanged(self, index):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
res = ""
if index == 0:
res = Valve_Ctrl.flowmeter1_open()
elif index == 1:
res = Valve_Ctrl.flowmeter1_close()
elif index == 2:
res = Valve_Ctrl.flowmeter2_open()
elif index == 3:
res = Valve_Ctrl.flowmeter2_close()
elif index == 4:
res = Valve_Ctrl.flowmeter3_open()
elif index == 5:
res = Valve_Ctrl.flowmeter3_close()
elif index == 6:
res = Valve_Ctrl.airpump_open()
elif index == 7:
res = Valve_Ctrl.airpump_close()
else:
pass
self.pcb_ctrl_return.setText(str(res))
@pyqtSignature("int")
def on_flowmeter_addr_currentIndexChanged(self, index):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
self.flowapi.comm_close()
self.flowapi = C_S48(self.s48_port, index+1)
print index+1
@pyqtSignature("")
def on_flowmeter_read_clicked(self):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
para_index = self.flowmeter_para.currentIndex()
try:
para_value = self.flowapi.read_para(REG_DICT[para_index])
self.flowmeter_readpara.setText(str(para_value))
except Exception,e:
print e
self.flowmeter_readpara.setText('NA')
@pyqtSignature("")
def on_flowmeter_write_clicked(self):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
value_str = self.flowmeter_writepara.text()
if value_str:
para_value = int(value_str)
para_index = self.flowmeter_para.currentIndex()
para_reg = REG_DICT[para_index]
self.flowapi.write_para(para_reg, para_value)
@pyqtSignature("int")
def on_ai518p_addr_currentIndexChanged(self, index):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
pass
@pyqtSignature("int")
def on_ai518p_para_currentIndexChanged(self, index):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
pass
@pyqtSignature("")
def on_ai518p_read_clicked(self):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
para_no = self.ai518p_para.currentIndex()
try:
para_dict = ai518p_api.read_para(PARA_NAME[para_no])
self.ai518p_read_para.setText(str(para_dict['PARA']))
except Exception,e:
print e
self.ai518p_read_para.setText('NA')
@pyqtSignature("")
def on_ai518p_write_clicked(self):
"""
Slot documentation goes here.
"""
# TODO: not implemented yet
para_no = self.ai518p_para.currentIndex()
para_val = int(self.ai518p_write_para.text())
ai518p_api.write_para(PARA_NAME[para_no],para_val)
@pyqtSignature("")
def on_restore_518p_clicked(self):
for no in xrange(0,26):
try:
print PARA_NAME[no],PARA_DEFAULT[no]
ai518p_api.write_para(PARA_NAME[no],PARA_DEFAULT[no])
except:
print "PARA %s restore failed" % PARA_NAME[no]
time.sleep(1)
PyQt4.QtGui.QMessageBox.information(self,u'提示', u'AI-518P恢复出厂成功!')
@pyqtSignature("")
def on_start_AT_clicked(self):
print "start"
self.xtime = 0
self.xdata = []
self.data_pv = []
self.data_sv = []
# self.AT_MPL.clear_curve()
target_temp = int(self.PID_temp.text())
ai518p_api.write_para('CtrL', 2)
ai518p_api.write_para('c01', target_temp*10)
ai518p_api.write_para('t01', 50)
ai518p_api.write_para('c02', target_temp*10)
ai518p_api.write_para('t01', -1)
ai518p_api.write_para('RUNSTA', 0)
self.AT_MPL.change_y(1, target_temp*1.5)
self.timer.start(1000)
def measure(self):
self.xtime +=1
self.xdata.append(self.xtime)
pv,sv = ai518p_api.get_psv()
self.data_pv.append(float(pv))
self.data_sv.append(float(sv))
self.now_PV.setText(str(pv))
self.now_SV.setText(str(sv))
self.now_temp.setText(str(pv))
# print "SV:",self.data_sv
# print "PV:",self.data_pv
if self.xtime == 1:
self.AT_MPL.generateData(self.xdata, self.data_pv, 'g', 'PV', 1)
self.AT_MPL.generateData(self.xdata, self.data_sv, 'r', 'SV', 1)
else:
self.AT_MPL.generateData(self.xdata, self.data_pv, 'g', 'PV', 0)
self.AT_MPL.generateData(self.xdata, self.data_sv, 'r', 'SV', 0)
self.is_at_finish()
def is_at_finish(self):
ctrl = ai518p_api.read_para('CtrL')['PARA']
if ctrl == 3:
self.timer.stop()
PyQt4.QtGui.QMessageBox.information(self,u'提示', u'恭喜!自整定完成!')
M5_hold = ai518p_api.read_para('M5')['PARA']
self.para_M5.setText(str(M5_hold))
P_rate = ai518p_api.read_para('P')['PARA']
self.para_P.setText(str(P_rate))
t_delay = ai518p_api.read_para('t')['PARA']
self.para_t.setText(str(t_delay))
@pyqtSignature("")
def on_stop_AT_clicked(self):
print "stop"
ai518p_api.set_stop()
self.timer.stop()
self.AT_MPL.clear_curve()
def read_conf(self):
ai518p_port = read_config(SYS_CONF_PATH, 'AI518P', 'port')
self.com_518p.setCurrentIndex(int(ai518p_port[-1])-1)
self.s48_port = read_config(SYS_CONF_PATH, 'HMTS48', 'port')
self.com_flowmeter.setCurrentIndex(int(self.s48_port[-1])-1)
pcb_port = read_config(SYS_CONF_PATH, 'PCB', 'port')
self.com_pcb.setCurrentIndex(int(pcb_port[-1])-1)
inst2400_port = Keithley2400.get_gpibport()
if inst2400_port:
self.com_2400.setItemText(0,inst2400_port)
else:
self.com_2400.setItemText(0,'NA')
ai518p_baud = read_config(SYS_CONF_PATH, 'AI518P', 'baud')
self.baud_518p.setCurrentIndex(int(ai518p_baud)/9600/2)
s48_baud = read_config(SYS_CONF_PATH, 'HMTS48', 'baud')
self.baud_flowmeter.setCurrentIndex(int(s48_baud)/9600/2)
pcb_baud = read_config(SYS_CONF_PATH, 'PCB', 'baud')
self.baud_pcb.setCurrentIndex(int(pcb_baud)/9600/2)
self.addr_518p = self.ai518p_addr.currentIndex()+1
self.addr_flowmeter = self.flowmeter_addr.currentIndex()+1
flow1 = read_config(SYS_CONF_PATH, 'HMTS48', 'flow1_range')
self.range1.setCurrentIndex(flow_index[flow1])
flow2 = read_config(SYS_CONF_PATH, 'HMTS48', 'flow2_range')
self.range2.setCurrentIndex(flow_index[flow2])
flow3 = read_config(SYS_CONF_PATH, 'HMTS48', 'flow3_range')
self.range3.setCurrentIndex(flow_index[flow3])
flow_addr = self.flowmeter_addr.currentIndex() + 1
self.flowapi = C_S48(self.s48_port, flow_addr)
# M5_hold = ai518p_api.read_para('M5')['PARA']
# self.para_M5.setText(str(M5_hold))
# P_rate = ai518p_api.read_para('P')['PARA']
# self.para_P.setText(str(P_rate))
# t_delay = ai518p_api.read_para('t')['PARA']
# self.para_t.setText(str(t_delay))
@pyqtSignature("int")
def on_tabWidget_currentChanged(self,index):
# pass
if index==2:
try:
M5_hold = ai518p_api.read_para('M5')['PARA']
self.para_M5.setText(str(M5_hold))
P_rate = ai518p_api.read_para('P')['PARA']
self.para_P.setText(str(P_rate))
t_delay = ai518p_api.read_para('t')['PARA']
self.para_t.setText(str(t_delay))
except:
self.para_M5.setText("NA")
self.para_P.setText("NA")
self.para_t.setText("NA")
def closeEvent(self, event):
pass
def disp_sys_set():
UI_SET = sys_set_ui()
UI_SET.show()
UI_SET.exec_()
return True
#运行UI APP
if __name__ == "__main__":
app = PyQt4.QtGui.QApplication(sys.argv)
UI_SYS_SET = sys_set_ui()
UI_SYS_SET.show()
sys.exit(app.exec_())
'''
自整定具体操作步骤:
1、长按半圆带箭头的键,将里面CTRL改为2。
2、Co1设定为400;
3、按半圆带箭头的键,出现to1,设定为50
4、co2设定为400
5、to2,设定为-1
6、按运行键启动,此时OP1指示灯会亮红色,SV界面中会显示AT字样
6、自整定刚结束后CTRL将变为3
'''