dmved(1) Manual Page

NAME

dmved - reads status of connected MPPT charger or battery shunt

SYNOPSIS

dmved --help

dmved --version

dmved --config file [--name name] [--node id] [--sensor id] [--target id] [--logger name] [--path path] [--receiver name] [--interval seconds] [--dump path] [--debug] [--verbose]

DESCRIPTION

This program captures status data received from a connected Maximum Power Point Tracking (MPPT) solar charge controller or SmartShunt battery monitor by Victron Energy, using the VE.Direct protocol. Only the BlueSolar/SmartSolar MPPT series and the SmartShunt monitor are supported. The serial port will be configured to 19200 baud (8N1). Observations are forwarded via message queue in the given interval if a receiver is specified.

The following VE.Direct fields are captured, depending on the device:

Alarm

Alarm condition active (on/off).

AR

Alarm reason.

CE

Consumed amp hours (mAh).

CS

State of operation.

DM

Mid-point deviation of the battery bank (%/10).

ERR

Error code.

H1

Depth of the deepest discharge (mAh).

H2

Depth of the last discharge (mAh).

H3

Depth of the average discharge (mAh).

H4

Number of charge cycles.

H5

Number of full discharges.

H6

Cumulative amp hours drawn (mAh).

H7

Minimum main (battery) voltage (mV).

H8

Maximum main (battery) voltage (mV).

H9

Number of seconds since last full charge (sec).

H10

Number of automatic synchronisations.

H11

Number of low main voltage alarms.

H12

Number of high main voltage alarms.

H15

Minimum auxiliary (battery) voltage (mV).

H16

Maximum auxiliary (battery) voltage (mV).

H17

Amount of produced energy (kWh/100).

H18

Amount of consumed energy (kWh/100).

H19

Yield total (kWh/100).

H20

Yield today (kWh/100).

H21

Maximum power today (W).

H22

Yield yesterday (kWh/100).

H23

Maximum power yesterday (W).

HSDS

Day sequence number (0 to 364).

I

Main or channel 1 battery current (mA).

IL

Load current (mA).

LOAD

Load output state (on/off).

MON

DC monitor mode.

MPPT

Tracker operation mode.

OR

Off reason.

P

Instantaneous power (W).

PPV

Panel power (W).

Relay

Relay state (on/off).

SOC

State-of-charge (%/10).

T

Battery temperature (degrees Celsius).

TTG

Time-to-go (min).

V

Main or channel 1 (battery) voltage (mV).

VM

Mid-point voltage of the battery bank (mV).

VPV

Panel voltage (mV).

VS

Auxiliary (starter) voltage (mV).

The response names equal the field names in lower-case.

OPTIONS

--config, -c file

File path to the configuration file.

--debug, -D

Forward logs messages of level LL_DEBUG via IPC (if logger is set).

--device, -d [mppt|shunt]

Connected device, either MPPT or SmartShunt.

--dump, -o path

Path of file or named pipe to dump received raw data to.

--help, -h

Print available command-line arguments and quit.

--interval, -I seconds

Observation emit interval in seconds (default is 60 seconds).

--logger, -l name

Name of logger. If set, sends logs to dmlogger(1) process of given name.

--name, -n name

Name of program instance and configuration (default is dmved).

--node, -N id

Node id.

--path, -p path

Path to TTY device (for example, /dev/ttyUSB0).

--receiver, -r name

Name of the observation receiver, without leading /.

--sensor, -S id

Sensor id.

--target, -T id

Target id.

--verbose, -V

Print log messages to stderr.

--version, -v

Print version information and quit.

EXIT STATUS

0

Success. Process terminated without errors.

1

Failure. Process failed.

EXAMPLE

Read status data from MPPT connected via TTL:

$ dmved --name dmved --config /usr/local/etc/dmpack/dmved.conf --verbose

RESOURCES

Project web site: https://www.dabamos.de/

COPYING

Copyright © 2025 Philipp Engel.