Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathINA260.py
executable file
·421 lines (330 loc) · 12.9 KB
/
INA260.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
import smbus
import time
# This code is derived from the Arduino code developed by Adafruit
# along with the TI documentation to the INA260 IC.
# The byte order coming out of the INA260 is reversed from normal SMbus or I2C
# There is a lot of byte switching down below.
# Creating an INA260 object and then calling the member functions
# readVoltage()
# readCurrent()
# readPower()
# should be enough to get started.
# The alarm functions set alarm types and can only be called once.
# In order for the alarm to work on the Pi, the pull-up for whatever GPIO
# you are using needs to be set to pull-up using gpio.PUD_UP.
# The alarm pin will be normally high and will go low during an alarm condition.
# The alarm functions can only be set once. Changing the alarm function requires
# resetting the chip. The reset requirement is specific to this interface module.
# The initialization code sets the INA260 to continuous sampling in case
# it was previously disabled. This is the default mode.
# Calling the member function setModeShutdown() will shut down the
# board to reduce current usage if not in use.
def bswap(val):
ret = ((val>>8) & 0xff) + ((val & 0xff)<<8)
return ret
# The I2C address can be changed by bridging the address pads on the Adafruit circuit
# board. The addresses below are untested.
INA260_I2CADDR_DEFAULT = 0x40 # INA260 default i2c address
INA260_I2CADDR_A0 = 0x41 # A0 connected to Vcc
INA260_I2CADDR_A1 = 0x44 # A1 connected to Vcc
INA260_I2CADDR_A0A1 = 0x45 # A0 and A1 connected to Vcc
# Contants for talking to the INA260
INA260_REG_CONFIG = 0x00 # Configuration register
INA260_REG_CURRENT = 0x01 # Current measurement register (signed) in mA
INA260_REG_BUSVOLTAGE = 0x02 # Bus voltage measurement register in mV
INA260_REG_POWER = 0x03 # Power calculation register in mW
INA260_REG_MASK_ENABLE = 0x06 # Interrupt/Alert setting and checking register
INA260_REG_ALERT_LIMIT = 0x07 # Alert limit value register
INA260_REG_MFG_UID = 0xFE # Manufacturer ID Register
INA260_REG_DIE_UID = 0xFF # Die ID and Revision Register
INA260_MODE_SHUTDOWN = 0x00 # SHUTDOWN: Minimize quiescient current and
# turn off current into the device inputs. Set
# another mode to exit shutown mode **/
INA260_MODE_TRIGGERED = 0x03 # TRIGGERED: Trigger a one-shot measurement
# of current and bus voltage. Set the TRIGGERED
# mode again to take a new measurement **/
INA260_MODE_CONTINUOUS = 0x07 # CONTINUOUS: (Default) Continuously update
INA260_TIME_140_us = 0x0 # Measurement time: 140us
INA260_TIME_204_us = 0x1 # Measurement time: 204us
INA260_TIME_332_us = 0x2 # Measurement time: 332us
INA260_TIME_558_us = 0x3 # Measurement time: 558us
INA260_TIME_1_1_ms = 0x4 # Measurement time: 1.1ms (Default)
INA260_TIME_2_116_ms = 0x5 # Measurement time: 2.116ms
INA260_TIME_4_156_ms = 0x6 # Measurement time: 4.156ms
INA260_TIME_8_244_ms = 0x7 # Measurement time: 8.244ms
INA260_COUNT_1 = 0x0 # Window size: 1 sample (Default)
INA260_COUNT_4 = 0x1 # Window size: 4 samples
INA260_COUNT_16 = 0x2 # Window size: 16 samples
INA260_COUNT_64 = 0x3 # Window size: 64 samples
INA260_COUNT_128 = 0x4 # Window size: 128 samples
INA260_COUNT_256 = 0x5 # Window size: 256 samples
INA260_COUNT_512 = 0x6 # Window size: 512 samples
INA260_COUNT_1024 = 0x7 # Window size: 1024 samples
voltageScale = 0.00125
currentScale = 0.00125
powerScale = 0.01
ALARM_NOTSET = 0
ALARM_HIGHVOLTAGE = 1
ALARM_LOWVOLTAGE = 2
ALARM_HIGHCURRENT = 3
ALARM_LOWCURRENT = 4
ALARM_OVERPOWER = 5
class INA260(object):
_myAddr = INA260_I2CADDR_DEFAULT
_myBus = None
_myAlarmType = ALARM_NOTSET
def __init__(self, addr=INA260_I2CADDR_DEFAULT):
self._myAddr = addr
self._myBus = smbus.SMBus(1)
try:
# We would like to call the checkCorrectDevice member function here
# but Python won't let us.
reg = self._myBus.read_word_data(addr, INA260_REG_MFG_UID)
if reg != 0x4954:
raise Exception("Wrong type of part at address 0x%x" % (addr))
self._myBus.write_word_data(addr, INA260_REG_CONFIG, 0x80)
except:
self._myBus = None
def _readAnalog(self, param, scale):
if self._myBus:
analog = self._myBus.read_word_data(self._myAddr, param)
analog = bswap(analog) * scale
else:
analog = None
return(analog)
def _writeAnalog(self, param, analog, scale):
if self._myBus:
analog = int(analog / scale)
analog = bswap(analog)
self._myBus.write_word_data(self._myAddr, param, analog)
def _readDigital(self, param):
if self._myBus:
dig = self._myBus.read_word_data(self._myAddr, param)
dig = bswap(dig)
else:
dig = None
return(dig)
def _writeDigital(self, param, dig):
if self._myBus:
dig = bswap(dig)
self._myBus.write_word_data(self._myAddr, param, dig)
def _setOpMode(self, mode):
if self._myBus:
reg = self._myBus.read_word_data(self._myAddr, INA260_REG_CONFIG)
reg = bswap(reg)
reg = (reg & 0xFFF0) + mode
reg = bswap(reg)
self._myBus.write_word_data(self._myAddr, INA260_REG_CONFIG, reg)
def _setAvgMode(self, mode):
if self._myBus:
reg = self._myBus.read_word_data(self._myAddr, INA260_REG_CONFIG)
reg = bswap(reg)
reg = (reg & 0xF1FF) + (mode << 9)
reg = bswap(reg)
self._myBus.write_word_data(self._myAddr, INA260_REG_CONFIG, reg)
def _setCurrCnvTime(self, time):
if self._myBus:
reg = self._myBus.read_word_data(self._myAddr, INA260_REG_CONFIG)
reg = bswap(reg)
reg = (reg & 0xFFC7) + (time << 3)
reg = bswap(reg)
self._myBus.write_word_data(self._myAddr, INA260_REG_CONFIG, reg)
def _setVoltCnvTime(self, time):
if self._myBus:
reg = self._myBus.read_word_data(self._myAddr, INA260_REG_CONFIG)
reg = bswap(reg)
reg = (reg & 0xFE3F) + (time << 6)
reg = bswap(reg)
self._myBus.write_word_data(self._myAddr, INA260_REG_CONFIG, reg)
### Public methods
def getAddress(self):
return(self._myAddr)
# Methods to read the voltage, current, and power
def readVoltage(self):
voltage = self._readAnalog(INA260_REG_BUSVOLTAGE, voltageScale)
return(voltage)
def readCurrent(self):
current = self._readAnalog(INA260_REG_CURRENT, currentScale)
return(current)
def readPower(self):
power = self._readAnalog(INA260_REG_POWER, powerScale)
return(power)
def readMode(self):
mode = self._readDigital(INA260_REG_CONFIG) & 0x7
return(mode)
def readAvgMode(self):
mode = self._readDigital(INA260_REG_CONFIG)
mode = (mode >> 9) & 0x7
return(mode)
def readVoltCnvTime(self):
mode = self._readDigital(INA260_REG_CONFIG)
mode = (mode >> 6) & 0x7
return(mode)
def readCurrCnvTime(self):
mode = self._readDigital(INA260_REG_CONFIG)
mode = (mode >> 3) & 0x7
return(mode)
def readConfig(self):
reg = self._readDigital(INA260_REG_CONFIG)
return(reg)
def resetConfig(self):
self._writeDigital(INA260_REG_CONFIG, 0x8000)
self._myAlarmType = ALARM_NOTSET
def setModeShutdown(self):
self._setOpMode(INA260_MODE_SHUTDOWN)
def setModeTriggered(self):
self._setOpMode(INA260_MODE_TRIGGERED)
def setModeContinuous(self):
self._setOpMode(INA260_MODE_CONTINUOUS)
# Functions to set the averaging mode in terms of the number of samples
def setAvgMode_1(self):
self._setAvgMode(INA260_COUNT_1)
def setAvgMode_4(self):
self._setAvgMode(INA260_COUNT_4)
def setAvgMode_16(self):
self._setAvgMode(INA260_COUNT_16)
def setAvgMode_64(self):
self._setAvgMode(INA260_COUNT_64)
def setAvgMode_128(self):
self._setAvgMode(INA260_COUNT_128)
def setAvgMode_256(self):
self._setAvgMode(INA260_COUNT_256)
def setAvgMode_512(self):
self._setAvgMode(INA260_COUNT_512)
def setAvgMode_1024(self):
self._setAvgMode(INA260_COUNT_1024)
# Functions to set the conversion times for current or voltage measurements.
# Functions with 'Curr' or 'Volt' in the name set the conversion times for
# current or voltage, respectively. Functions without 'Curr' or 'Volt' in the
# name are convenience functions that set both parameters to be the same.
def setCurrCnvTime_140usec(self):
self._setCurrCnvTime(INA260_TIME_140_us)
def setVoltCnvTime_140usec(self):
self._setVoltCnvTime(INA260_TIME_140_us)
def setCnvTime_140usec(self):
self.setCurrCnvTime_140usec()
self.setVoltCnvTime_140usec()
def setCurrCnvTime_204usec(self):
self._setCurrCnvTime(INA260_TIME_204_us)
def setVoltCnvTime_204usec(self):
self._setVoltCnvTime(INA260_TIME_204_us)
def setCnvTime_204usec(self):
self.setCurrCnvTime_204usec()
self.setVoltCnvTime_204usec()
def setCurrCnvTime_332usec(self):
self._setCurrCnvTime(INA260_TIME_332_us)
def setVoltCnvTime_332usec(self):
self._setVoltCnvTime(INA260_TIME_332_us)
def setCnvTime_332usec(self):
self.setCurrCnvTime_332usec()
self.setVoltCnvTime_332usec()
def setCurrCnvTime_588usec(self):
self._setCurrCnvTime(INA260_TIME_558_us)
def setVoltCnvTime_588usec(self):
self._setVoltCnvTime(INA260_TIME_588_us)
def setCnvTime_588usec(self):
self.setCurrCnvTime_588usec()
self.setVoltCnvTime_588usec()
def setCurrCnvTime_1_1ms(self):
self._setCurrCnvTime(INA260_TIME_1_1_ms)
def setVoltCnvTime_1_1ms(self):
self._setVoltCnvTime(INA260_TIME_1_1_ms)
def setCnvTime_1_1ms(self):
self.setCurrCnvTime_1_1ms()
self.setVoltCnvTime_1_1ms()
def setCurrCnvTime_2_116ms(self):
self._setCurrCnvTime(INA260_TIME_2_116_ms)
def setVoltCnvTime_2_116ms(self):
self._setVoltCnvTime(INA260_TIME_2_116_ms)
def setCnvTime_2_116ms(self):
self.setCurrCnvTime_2_116ms()
self.setVoltCnvTime_2_116ms()
def setCurrCnvTime_4_156ms(self):
self._setCurrCnvTime(INA260_TIME_4_156_ms)
def setVoltCnvTime_4_156ms(self):
self._setVoltCnvTime(INA260_TIME_4_156_ms)
def setCnvTime_4_156ms(self):
self.setCurrCnvTime_4_156ms()
self.setVoltCnvTime_4_156ms()
def setCurrCnvTime_8_244ms(self):
self._setCurrCnvTime(INA260_TIME_8_244_ms)
def setVoltCnvTime_8_244ms(self):
self._setVoltCnvTime(INA260_TIME_8_244_ms)
def setCnvTime_8_244ms(self):
self.setCurrCnvTime_8_244ms()
self.setVoltCnvTime_8_244ms()
# Functions to set alarm limits
# These functions are a one shot deal.
# Call resetConfig to completely reset the configuration and allow a change
# of the alarm.
def getAlarmType:
return self._myAlarmType
def setOverCurrentLimit(self, limit):
if self._myBus and (self._myAlarmType == ALARM_NOTSET):
self._writeAnalog(INA260_REG_ALERT_LIMIT, limit, currentScale)
mask = self._readDigital(INA260_REG_MASK_ENABLE)
mask = (mask & 0x0403) + 0x8000
self._writeDigital(INA260_REG_MASK_ENABLE, mask)
self._myAlarmType = ALARM_HIGHCURRENT
def setUnderCurrentLimit(self, limit):
if self._myBus and (self._myAlarmType == ALARM_NOTSET):
self._writeAnalog(INA260_REG_ALERT_LIMIT, limit, currentScale)
mask = self._readDigital(INA260_REG_MASK_ENABLE)
mask = (mask & 0x0403) + 0x4000
self._writeDigital(INA260_REG_MASK_ENABLE, mask)
self._myAlarmType = ALARM_LOWCURRENT
def setOverVoltageLimit(self, limit):
if self._myBus and (self._myAlarmType == ALARM_NOTSET):
self._writeAnalog(INA260_REG_ALERT_LIMIT, limit, voltageScale)
mask = self._readDigital(INA260_REG_MASK_ENABLE)
mask = (mask & 0x0403) + 0x2000
self._writeDigital(INA260_REG_MASK_ENABLE, mask)
self._myAlarmType = ALARM_HIGHVOLTAGE
def setUnderVoltageLimit(self, limit):
if self._myBus and (self._myAlarmType == ALARM_NOTSET):
self._writeAnalog(INA260_REG_ALERT_LIMIT, limit, voltageScale)
mask = self._readDigital(INA260_REG_MASK_ENABLE)
mask = (mask & 0x0403) + 0x1000
self._writeDigital(INA260_REG_MASK_ENABLE, mask)
self._myAlarmType = ALARM_LOWVOLTAGE
def setOverPowerLimit(self, limit):
if self._myBus and (self._myAlarmType == ALARM_NOTSET):
self._writeAnalog(INA260_REG_ALERT_LIMIT, limit, powerScale)
mask = self._readDigital(INA260_REG_MASK_ENABLE)
mask = (mask & 0x0403) + 0x800
self._writeDigital(INA260_REG_MASK_ENABLE, mask)
self._myAlarmType = ALARM_OVERPOWER
def setAlertLatch(self):
dig = self._readDigital(INA260_REG_MASK_ENABLE)
if dig:
dig = (dig & 0xFFFE) + 1
self._writeDigital(INA260_REG_MASK_ENABLE, dig)
def clearAlertLatch(self):
dig = self._readDigital(INA260_REG_MASK_ENABLE)
if dig:
dig = dig & 0xFFFE
self._writeDigital(INA260_REG_MASK_ENABLE, dig)
def setAlertPolarity(self, pol):
dig = self._readDigital(INA260_REG_MASK_ENABLE)
if dig:
if pol:
dig = (dig & 0xFFFD) + 2
else:
dig = dig & 0xFFFD
self._writeDigital(INA260_REG_MASK_ENABLE, dig)
# These are public functions but they are only useful for testing the API.
def readMaskEnable(self):
dig = self._readDigital(INA260_REG_MASK_ENABLE)
return (dig)
def readLimitRegister(self):
dig = self._readDigital(INA260_REG_ALERT_LIMIT)
return (dig)
def readManufID(self):
manufID = self._readDigital(INA260_REG_MFG_UID)
return manufID
def checkCorrectDevice(self):
manufID = self.readManufID()
if manufID == 0x5449:
return(True)
else:
return(False)