You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Go to Methods tab and add Constant Baseline Offset of 1 under Signal Processing
Go to Spin Systems tab
Add new 1H spin system
Observe baseline on the spectrum
Repeat from step 5 for desired number of spin systems
Expected behavior:
The spectrum always shows a baseline at 1
Observed behavior:
The spectrum baseline is dependent on the number of spin systems. For n>1 spin systems and a defined baseline offset of b the observed offset is n*b
The text was updated successfully, but these errors were encountered:
The individual spin systems have the signal processor operations applied before being combined into a spectrum. When each of n spin systems each have a baseline offset of b applied then adding them together will result in a spectrum baseline offset of n*b
Steps to reproduce:
Expected behavior:
The spectrum always shows a baseline at 1
Observed behavior:
The spectrum baseline is dependent on the number of spin systems. For
n>1
spin systems and a defined baseline offset ofb
the observed offset isn*b
The text was updated successfully, but these errors were encountered: