Notifications
You must be signed in to change notification settings - Fork 178
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
resultGUI.w to dij #713
Comments
Your mapping seems correct, and I don't agree that this is not "logical". matRad does not use an analytic SOBP-Formula to determine weights, which would give you monotonic increasing weights, but performs full IMPT optimization. Thus, there is no "strict" rule that the weights should increase. However, you still see the trend that intensities increase towards higher energies (if the last value is the weight). |
Thanks Niklas,
I have one question about ct data in mat files. does it contain HU units or stopping powers? in case of matrad default TG119 file.
I guess this 3D matrix includes stopping powers
…________________________________
From: Niklas Wahl ***@***.***>
Sent: 03 May 2024 18:31
To: e0404/matRad ***@***.***>
Cc: Mariam Abuladze ***@***.***>; Author ***@***.***>
Subject: Re: [e0404/matRad] resultGUI.w to dij (Issue #713)
Your mapping seems correct, and I don't agree that this is not "logical". matRad does not use an analytic SOBP-Formula to determine weights, which would give you monotonic increasing weights, but performs full IMPT optimization. Thus, there is no "strict" rule that the weights should increase. However, you still see the trend that intensities increase towards higher energies (if the last value is the weight).
—
Reply to this email directly, view it on GitHub<#713 (comment)>, or unsubscribe<https://github.com/notifications/unsubscribe-auth/ASBXGRH75GAHQOT3MSQUF53ZAONSRAVCNFSM6AAAAABHAKEST2VHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDAOJTGE2DAMZQGQ>.
You are receiving this because you authored the thread.Message ID: ***@***.***>
|
Sorry, I already got an answer for previous question,
file consists ct cube and HU cube too.
But There is now way how to guess with which materials dies voxel consist of. Is there any way to guess it? As I need it to simulate phantom in Geant4.
Thanks,
Mariam
…________________________________
From: Mariam Abuladze ***@***.***>
Sent: 04 May 2024 00:04
To: e0404/matRad ***@***.***>
Subject: Re: [e0404/matRad] resultGUI.w to dij (Issue #713)
Thanks Niklas,
I have one question about ct data in mat files. does it contain HU units or stopping powers? in case of matrad default TG119 file.
I guess this 3D matrix includes stopping powers
________________________________
From: Niklas Wahl ***@***.***>
Sent: 03 May 2024 18:31
To: e0404/matRad ***@***.***>
Cc: Mariam Abuladze ***@***.***>; Author ***@***.***>
Subject: Re: [e0404/matRad] resultGUI.w to dij (Issue #713)
Your mapping seems correct, and I don't agree that this is not "logical". matRad does not use an analytic SOBP-Formula to determine weights, which would give you monotonic increasing weights, but performs full IMPT optimization. Thus, there is no "strict" rule that the weights should increase. However, you still see the trend that intensities increase towards higher energies (if the last value is the weight).
—
Reply to this email directly, view it on GitHub<#713 (comment)>, or unsubscribe<https://github.com/notifications/unsubscribe-auth/ASBXGRH75GAHQOT3MSQUF53ZAONSRAVCNFSM6AAAAABHAKEST2VHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDAOJTGE2DAMZQGQ>.
You are receiving this because you authored the thread.Message ID: ***@***.***>
|
matRad has no builtin function to do that, only for HU -> rSP / rED lookup. You should look into Schneider et al (2000) to figure out how to do it. When we forward to Monte Carlo codes like MCsquare or TOPAS, we rely on such conversion schemes provided by those codes (or do water-equivalent simulations). |
Dear Niklas,
Thanks for your answers.
Although there are some issues still. as it is visible on screeshot, HU units of TG119 are mostly close to -1000 which is considered to be air. but proton energies in optimized beams in matRad are between 80 and 110 MeV, so according to Geant4 simulations proton with these energies can not be stopped in air Phantom of this size, as the densities of voxels are close to 0.026 according to octave.
Is there something wrong with matRad simulations? Or I might have a mistake.
Thanks so much,
Mariam Abuladze
…________________________________
From: Niklas Wahl ***@***.***>
Sent: 05 May 2024 04:01
To: e0404/matRad ***@***.***>
Cc: Mariam Abuladze ***@***.***>; Author ***@***.***>
Subject: Re: [e0404/matRad] resultGUI.w to dij (Issue #713)
matRad has no builtin function to do that, only for HU -> rSP / rED lookup. You should look into Schneider et al (2000)<https://doi.org/10.1088/0031-9155/45/2/314> to figure out how to do it. When we forward to Monte Carlo codes like MCsquare or TOPAS, we rely on such conversion schemes provided by those codes (or do water-equivalent simulations).
—
Reply to this email directly, view it on GitHub<#713 (comment)>, or unsubscribe<https://github.com/notifications/unsubscribe-auth/ASBXGREVF3XQMALO62MLOY3ZAVZHHAVCNFSM6AAAAABHAKEST2VHI2DSMVQWIX3LMV43OSLTON2WKQ3PNVWWK3TUHMZDAOJUGUYDKNRZGU>.
You are receiving this because you authored the thread.Message ID: ***@***.***>
|
The TG119 phantom image includes a lot of air (which is at ~-1000), but the water phantom itself has consistently values a bit higher than 0 (between 0-30 HU). figure; hist(ct.cubeHU{1}(cst{3,4}{1})) So I don't really understand how you end up with TG119 having mostly air? |
This issue was automatically marked as stale because it has been sitting there for 14 days without activity. It will be closed in 14 days if no further activity occurs. |
Dear friends,
As it is mentioned in matRad documentation dij variable includes information about number of each bixel in each Ray in a beam.
But, weights created after optimization is stored in resultGui.w. how can I reconstruct one to one mapping from weights to bixel ID?
I did some such kind of mapping so that firsk element in resultGui.w corresponds to a first element in dij.bixelnumber, but the issue is that low energetic bixel has higher intensity (like it is shown on picture) and it not logical.
Thanks,
![Screenshot from 2024-04-30 17-46-58](https://private-user-images.githubusercontent.com/75723588/326834028-786c9ded-38fa-4903-bb41-029766536502.png?jwt=eyJhbGciOiJIUzI1NiIsInR5cCI6IkpXVCJ9.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.7ansYmCLxuwbYbgXmWUox-Q3W7DaFk0nPvJql370hXo)
Mariam
The text was updated successfully, but these errors were encountered: