Offline Recording

The offline recording makes it possible to record data into Polar device internal memory. The recording continues even though the BLE connection is lost while recording.

Basic usage

To enable the offline recording the feature FEATURE_POLAR_OFFLINE_RECORDING must be opted in at the time of Polar BLE SDK instantiation. Once the BLE connection is created to the Polar device the bleSdkFeatureReady callback is called by the SDK with feature FEATURE_POLAR_OFFLINE_RECORDING indicating the offline recording functionality is available in Polar device and it is ready to be used. From this point onwards the offline recording API functions, exposed in the PolarOfflineRecordingApi interface, are available and usable.

To know which data types are supported in the particular Polar device, the getAvailableOfflineRecordingDataTypes function can used to check the availability.

The API PolarOfflineRecordingApi has the basic functions to start startOfflineRecording and stop stopOfflineRecording offline recording. Status query of API function getOfflineRecordingStatus indicates if device is already having active recordings on going.

The listing of recordings saved in device memory can be done with listOfflineRecordings. The listing returns all the entries (PolarOfflineRecordingEntry) in the device or empty list if no recordings found. Using the PolarOfflineRecordingEntry it is possible to read the record with the getOfflineRecord and delete it with removeOfflineRecord.

To know what are the capabilities of each PolarDeviceDataType in offline recording, the settings shall be queried by the requestOfflineRecordingSettings. The wanted settings are then provided as parameter for startOfflineRecording.

Advanced usage

SDK Mode

The offline recording can be used in SDK mode. The SDK mode provides wider range of settings to be used, to know the available settings in SDK mode for offline recording the settings can be queried by the requestFullOfflineRecordingSettings. Please note that in SDK Mode, it is not possible to perform operations such as listing offline recordings (listOfflineRecordings), reading specific offline recording (getOfflineRecord), or deleting offline recordings (removeOfflineRecord).

Offline recording triggers

Triggers are the way to automatically start the offline recording. The options are TRIGGER_SYSTEM_START and TRIGGER_EXERCISE_START. In case the trigger is set to TRIGGER_SYSTEM_START the offline recording is started every time the Polar device is switched on, e.g. when VeritySense device power button is pressed by the user to turn device on. In case the trigger is set to TRIGER_EXERCISE_START the offline recording is started every time exercise is started in Polar device. With the VeritySense TRIGER_EXERCISE_START will trigger offline recording if either the exercise or swimming mode is started by the user of VeritySense.

The API setOfflineRecordingTrigger is used to setup the trigger. When the offline recording is automatically started by the trigger the recording will end in two conditions, either recording is stopped by stopOfflineRecording or user switch off the device. To disable the trigger the setOfflineRecordingTrigger function is called with the option TRIGGER_DISABLED

Memory management

The device does not automatically erase offline recordings to make space for new ones. If there is less than 2 MB of memory left when a new recording is started, the device will respond with the DISK_FULL error when startOfflineRecording is subscribed. Similarly, the same 2 MB memory limit prevents the setting of new triggers with setOfflineRecordingTrigger.

In addition, please note that the device will automatically stop the offline recording when there is less than 300 kB of free space remaining. At this point, all offline recording triggers will also be disabled.

Security

The offline record saved in device memory can be encrypted by providing the 128bit AES key as parameter for startOfflineRecording request. If providing the key with the startOfflineRecording request, the exact same key must be provided in getOfflineRecord to be able to read out the offline record. Each of the started recoding may be started with different key. The key management is not provided by the SDK, but the application developer shall implement the key management. It is recommended the security option is used, otherwise it might be possible by others to read out recordings in VeritySense.

Availability

Device Version onwards
Polar Verity Sense 2.1.0
Polar 360 1.0

Considerations

The online streaming and offline recording do not work same time for the same data type. For example if either accelerometer offline recording or the accelerometer online streaming is started, the attempt to start the online streaming or offline recording at this state will return the error ERROR_ALREADY_IN_STATE.

The offline recording read getOfflineRecord and delete removeOfflineRecord can be called while the offline recording is recording, but that is not recommended. It is recommended to stop the offline recording by stopOfflineRecording before trying to access the recording with getOfflineRecord or removeOfflineRecord functions.