Modbus.c - a Modbus TCP Slave Library for Netcruzer (PIC24)
EMMERTEX - Andrew Frahn
https://github.com/emmertex/Modbus-Library/
Ported from Siamects variation of Mudbus.cpp by Dee Wykoff
Arduino Library - http://gitorious.org/mudbus
This program is free software: you can redistribute it and/or modify
it under the terms of the GNU General Public License as published by
the Free Software Foundation, either version 3 of the License, or
(at your option) any later version.
This program is distributed in the hope that it will be useful,
but WITHOUT ANY WARRANTY; without even the implied warranty of
MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
GNU General Public License for more details.
You should have received a copy of the GNU General Public License
along with this program. If not, see <http://www.gnu.org/licenses/>.
*/
//#define MbDebug //extra debugging, see Modbus.c
#include <stdbool.h>
#include <stdint.h>
#ifndef Modbus_h
#define Modbus_h
#define MB_C 64 //Holding Coils (commonly 0x)
#define MB_I 16 //Input Coils (commonly 1x)
#define MB_IR 32 //Input Registers (commonly 3x)
#define MB_HR 64 //Holding Registers (commonly 4x)
#define MB_PORT 502 //Modbus Port (default is 502)
// Global Variables ///////////////////////////////////
#if !defined(THIS_IS_MODBUS_C)
extern BOOL MBC[MB_C];
extern BOOL MBI[MB_I];
extern WORD MBIR[MB_IR];
extern WORD MBR[MB_HR];
#endif
// Function Prototypes ///////////////////////////////////
void MBRun();
void MFSetFC(WORD fc);
void MBPopulateSendBuffer(BYTE *SendBuffer, WORD NoOfBytes);
void MBbuffer_restore();
void MBbuffer_save();
int word(BYTE a, BYTE b);
void MB_wFloat(float f, int i);
float MB_rFloat(int i);
/* Speculations on Modbus message structure:
**********************************************
**********Master(PC) request frames***********
00 ID high 0
01 ID low 1
02 Protocol high 0
03 Protocol low 0
04 Message length high 0
05 Message length low 6 (6 bytes after this)
06 Slave number 1
07 Function code
08 Start address high maybe 0
09 Start address low maybe 0
10 Length high maybe 125 or Data high if write
11 Length low maybe 125 or Data low if write
**********************************************
**********Slave response frames******
00 ID high echo / 0
01 ID low echo / slave ID 1
02 Protocol high echo
03 Protocol low echo
04 Message length high echo
05 Message length low num bytes after this
06 Slave number echo
07 Function code echo for OK, 80h+FC for Exception
08 Start address high num bytes of data for OK, else Exception Code
09 Data high
10 Data low
**********************************************
*/
/* Exception Codes
**********************************************
01 Illegal Function Implemented
02 Illegal Data Address Implemented
03 Illegal Data Value Not Needed? Application Specific?
04 Failure in Device Not Needed. Application Specific.
All others are program or special function related
**********************************************
*/
#endif /* MODBUS_H */