Hi @madalinaStreche, |
It might be due to autocalibration not being perfect, so quality of sniff depends on the physical position of the chameleon in the NFC field |
@madalinaStreche Sniffing in the direction from reader to card should normally work without problems. The opposite direction is much harder due to the weaker load modulation. So it might depend on setup, calibration etc as the others pointed out. |
The autocalibraton mode is available only for reading mode? It will help if I will run the autocalibration in reader mode first and then change to sniffing? |
Sniffing NFC fields is always a finicky process since reader's field is MUCH stronger than card modulation, which means picking a threshold to discriminate noise from actual data is nontrivial. Have a look at the scope captures in this post for more insight (it's about the Proxmark but the concepts are the same) https://swende.se/blog/PM3-development.html |
I try to record a communication between 2 devices, but from my logs it seems that Chameleon manages to sniff only in one direction: reader -> card. What about the transmitted data from the card to the reader? Are there any updates on this?