! LOAD DEFINITIONS
!
! Note that 1-phase loads have a voltage rating = to actual voltage across terminals
! This could be either 2.4kV for Wye connectoin or 4.16 kV for Delta or Line-Line connection.
! 3-phase loads are rated Line-Line (as are 2-phase loads, but there are none in this case).
! Only the balanced 3-phase loads are declared as 3-phase; unbalanced 3-phase loads are declared
! as three 1-phase loads.
New Load.S1a Bus1=1.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S2b Bus1=2.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S4c Bus1=4.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S5c Bus1=5.3 Phases=1 Conn=Wye Model=5 kV=2.4 kW=20.0 kvar=10.0
New Load.S6c Bus1=6.3 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S7a Bus1=7.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S9a Bus1=9.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S10a Bus1=10.1 Phases=1 Conn=Wye Model=5 kV=2.4 kW=20.0 kvar=10.0
New Load.S11a Bus1=11.1 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S12b Bus1=12.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S16c Bus1=16.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S17c Bus1=17.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S19a Bus1=19.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S20a Bus1=20.1 Phases=1 Conn=Wye Model=5 kV=2.4 kW=40.0 kvar=20.0
New Load.S22b Bus1=22.2 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S24c Bus1=24.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S28a Bus1=28.1 Phases=1 Conn=Wye Model=5 kV=2.4 kW=40.0 kvar=20.0
New Load.S29a Bus1=29.1 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S30c Bus1=30.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S31c Bus1=31.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S32c Bus1=32.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S33a Bus1=33.1 Phases=1 Conn=Wye Model=5 kV=2.4 kW=40.0 kvar=20.0
New Load.S34c Bus1=34.3 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S35a Bus1=35.1.2 Phases=1 Conn=Delta Model=1 kV=4.160 kW=40.0 kvar=20.0
New Load.S37a Bus1=37.1 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S38b Bus1=38.2 Phases=1 Conn=Wye Model=5 kV=2.4 kW=20.0 kvar=10.0
New Load.S39b Bus1=39.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S41c Bus1=41.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S42a Bus1=42.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S43b Bus1=43.2 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S45a Bus1=45.1 Phases=1 Conn=Wye Model=5 kV=2.4 kW=20.0 kvar=10.0
New Load.S46a Bus1=46.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S47 Bus1=47 Phases=3 Conn=Wye Model=5 kV=4.160 kW=105.0 kvar=75.0
New Load.S48 Bus1=48 Phases=3 Conn=Wye Model=2 kV=4.160 kW=210.0 kVAR=150.0
New Load.S49a Bus1=49.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=35.0 kvar=25.0
New Load.S49b Bus1=49.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=70.0 kvar=50.0
New Load.S49c Bus1=49.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=35.0 kvar=20.0 ! used to be 25 in on-line document
New Load.S50c Bus1=50.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S51a Bus1=51.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S52a Bus1=52.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S53a Bus1=53.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S55a Bus1=55.1 Phases=1 Conn=Wye Model=2 kV=2.4 kW=20.0 kvar=10.0
New Load.S56b Bus1=56.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S58b Bus1=58.2 Phases=1 Conn=Wye Model=5 kV=2.4 kW=20.0 kvar=10.0
New Load.S59b Bus1=59.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S60a Bus1=60.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S62c Bus1=62.3 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S63a Bus1=63.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S64b Bus1=64.2 Phases=1 Conn=Wye Model=5 kV=2.4 kW=75.0 kvar=35.0
New Load.S65a Bus1=65.1.2 Phases=1 Conn=Delta Model=2 kV=4.160 kW=35.0 kvar=25.0
New Load.S65b Bus1=65.2.3 Phases=1 Conn=Delta Model=2 kV=4.160 kW=35.0 kvar=25.0
New Load.S65c Bus1=65.3.1 Phases=1 Conn=Delta Model=2 kV=4.160 kW=70.0 kvar=50.0
New Load.S66c Bus1=66.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=75.0 kvar=35.0
New Load.S68a Bus1=68.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S69a Bus1=69.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S70a Bus1=70.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S71a Bus1=71.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S73c Bus1=73.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S74c Bus1=74.3 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S75c Bus1=75.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S76a Bus1=76.1.2 Phases=1 Conn=Delta Model=5 kV=4.160 kW=105.0 kvar=80.0
New Load.S76b Bus1=76.2.3 Phases=1 Conn=Delta Model=5 kV=4.160 kW=70.0 kvar=50.0
New Load.S76c Bus1=76.3.1 Phases=1 Conn=Delta Model=5 kV=4.160 kW=70.0 kvar=50.0
New Load.S77b Bus1=77.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S79a Bus1=79.1 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S80b Bus1=80.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S82a Bus1=82.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S83c Bus1=83.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S84c Bus1=84.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S85c Bus1=85.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S86b Bus1=86.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S87b Bus1=87.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S88a Bus1=88.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S90b Bus1=90.2 Phases=1 Conn=Wye Model=5 kV=2.4 kW=40.0 kvar=20.0
New Load.S92c Bus1=92.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S94a Bus1=94.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S95b Bus1=95.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S96b Bus1=96.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S98a Bus1=98.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S99b Bus1=99.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S100c Bus1=100.3 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S102c Bus1=102.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S103c Bus1=103.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S104c Bus1=104.3 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S106b Bus1=106.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S107b Bus1=107.2 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S109a Bus1=109.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=40.0 kvar=20.0
New Load.S111a Bus1=111.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0
New Load.S112a Bus1=112.1 Phases=1 Conn=Wye Model=5 kV=2.4 kW=20.0 kvar=10.0
New Load.S113a Bus1=113.1 Phases=1 Conn=Wye Model=2 kV=2.4 kW=40.0 kvar=20.0
New Load.S114a Bus1=114.1 Phases=1 Conn=Wye Model=1 kV=2.4 kW=20.0 kvar=10.0