Notifications
You must be signed in to change notification settings - Fork 16
/
smc_rnics.8
123 lines (100 loc) · 2.25 KB
/
smc_rnics.8
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
.\" Copyright IBM Corp. 2018
.TH SMC_RNICS 8 "October 2018" "smc-tools" "Linux Programmer's Manual"
.SH NAME
smc_rnics \- list, enable and disable (R)NICS as used by SMC-R and SMC-D
.SH SYNOPSIS
.B smc_rnics
.RB [ \-ahrv ]
.RB [ \-d
.IR FID ]
.RB [ \-e
.IR FID ]
.RI [ FID ]
.SH DESCRIPTION
The SMC protocol requires an (R)NIC for the (R)DMA traffic.
Use
.B smc_rnics
to handle, and to identify hotplugged (R)NICs.
.SH OPTIONS
By default,
.B smc_rnics
shows all enabled (R)NICs in the system.
.TP
.I FID
Limit output to the specified function ID
.RI ( FID ).
.TP
.BR "\-a, \-\-all"
Include disabled and unknown devices in output
.TP
.BR "\-d, \-\-disable " \fIFID
Set (R)NIC
.I FID
offline.
.TP
.BR "\-e, \-\-enable " \fIFID
Set (R)NIC
.I FID
online. Note that devices other than (R)NICs are not displayed by default and
therefore, once enabled, will not appear in further output unless option
.BR -a
or
.BR -r
is specified.
.TP
.BR "\-h, \-\-help"
Display a brief
.B smc_rnics
usage information.
.TP
.BR "\-I, \-\-IB-dev"
Display IB device information.
.TP
.BR "\-r, \-\-rawids"
Display raw PCI vendor and device codes in column. Note that this will
also include unknown devices.
.TP
.BR "\-v, \-\-version"
Display version information.
.SH OUTPUT
.SS "FID"
Function ID.
.SS "Power"
Indicates whether the PCI slot is on (1) or off (0). See option
.B -e
on how to enable a device that is offline.
.SS "PCI_ID"
PCI ID in BDF (Bus:Device.Function) notation.
.SS "PCHID"
Physical channel identifier, or virtual channel identifier (VCHID) for
ISM devices.
.SS "Type"
Device type in human readable form. See option
.B -r
to switch to display of PCI vendor and device instead.
.SS "PPrt"
Corresponding physical port of an RNIC, if applicable. Starts counting at 0.
.SS "IPrt"
Corresponding Infiniband port of an RNIC, if applicable. Starts counting at 1.
.SS "PNET_ID"
Physical network ID. Has an asterisk
.B *
appended if defined via
.BR smc_pnet .
.SS "Net-Dev"
Network interface in Linux, if applicable.
.SS "IB-Dev"
Infiniband interface in Linux, if applicable.
.SH RETURN CODES
On success,
.B smc_rnics
returns 0.
If an error occurs, a return code other than 0 is returned.
.P
.SH SEE ALSO
.BR af_smc (7),
.BR smc_pnet (8),
.BR smc_run (8),
.BR smcd (8),
.BR smcr (8),
.BR smcss (8)