Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathtransformer_report.tex
915 lines (727 loc) · 42.7 KB
/
transformer_report.tex
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
% Thin Sectioned Essay
% LaTeX Template
% Version 1.0 (3/8/13)
%
% This template has been downloaded from:
% http://www.LaTeXTemplates.com
%
% Original Author:
% Nicolas Diaz ([email protected]) with extensive modifications by:
% Vel ([email protected])
%
% License:
% CC BY-NC-SA 3.0 (http://creativecommons.org/licenses/by-nc-sa/3.0/)
%
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
%----------------------------------------------------------------------------------------
% PACKAGES AND OTHER DOCUMENT CONFIGURATIONS
%----------------------------------------------------------------------------------------
\documentclass[a4paper, 11pt]{article} % Font size (can be 10pt, 11pt or 12pt) and paper size (remove a4paper for US letter paper)
\usepackage[protrusion=true,expansion=true]{microtype} % Better typography
\usepackage{graphicx} % Required for including pictures
\graphicspath{{images/}}
\usepackage{wrapfig} % Allows in-line images
\usepackage{amsmath}
\usepackage{mathpazo} % Use the Palatino font
\usepackage[T1]{fontenc} % Required for accented characters
\linespread{1.05} % Change line spacing here, Palatino benefits from a slight increase by default
\makeatletter
\renewcommand\@biblabel[1]{\textbf{#1.}} % Change the square brackets for each bibliography item from '[1]' to '1.'
\renewcommand{\@listI}{\itemsep=0pt} % Reduce the space between items in the itemize and enumerate environments and the bibliography
\renewcommand{\maketitle}{ % Customize the title - do not edit title and author name here, see the TITLE block below
\begin{flushright} % Right align
{\LARGE\@title} % Increase the font size of the title
\vspace{50pt} % Some vertical space between the title and author name
{\large\@author} % Author name
\\\@date % Date
\vspace{40pt} % Some vertical space between the author block and abstract
\end{flushright}
}
%----------------------------------------------------------------------------------------
% TITLE
%----------------------------------------------------------------------------------------
\title{\textbf{High Frequency Transformer Design Report}\\ % Title
Work Package 4} % Subtitle
\author{\textsc{Ozan Keysan} % Author
\\{\textit{University of Edinburgh}}} % Institution
\date{\today} % Date
%----------------------------------------------------------------------------------------
\begin{document}
\maketitle % Print the title section
%----------------------------------------------------------------------------------------
% ABSTRACT AND KEYWORDS
%----------------------------------------------------------------------------------------
%\renewcommand{\abstractname}{Summary} % Uncomment to change the name of the abstract to something else
\begin{abstract}
This report presents the material options for the core of the medium frequency transformer that is being investigated within the Work Package 4 of the ``Next Generation HVDC Network for the Energy Industry'' project.
\end{abstract}
\hspace*{3,6mm}\textit{Keywords:} medium frequency transformer, HVDC transmission, core losses, HV transformer % Keywords
\vspace{30pt} % Some vertical space between the abstract and first section
%----------------------------------------------------------------------------------------
% ESSAY BODY
%----------------------------------------------------------------------------------------
\section{Introduction}
A literature review is presented by Robert Fox within WP 2, in which different medium-frequency transformers were compared and the components of medium-frequency transformers are listed. This report will focus on the suitable core materials for medium frequency transformers and the main loss components.
Transformers are the bulkiest part of the medium voltage conversion systems \cite{Agheb2012, Steiner2007}. Thus, there is a trend to reduce the size and weight of these components. In \cite{Prasai2007}, it is stated that the weight and size of a 3 MW 1.2 kHz transformer is less than 8\% of an equivalent 50 Hz line transformer. In Fig.~\ref{transformer-vols}, volume variation with operating frequency for a 1 MW transformer is presented. However, as the frequency is increased, skin effect, proximity effect, hysteresis losses and dielectric losses are significantly increased. Furthermore, the reduction in size usually implies same power loss in much smaller area, which demands forced cooling techniques as in \cite{Heinemann2002}.
In the transformer design, types of challenges change with increasing frequency. Important design factors in conventional line transformers and high frequency transformers are tabulated in Table~\ref{important}.
However, challenges of medium to high frequency transformers can be listed as
\cite{Villar2010}:
\begin{itemize}
\item Loss reduction for higher frequency range.
\item Efficient thermal management, higher power levels are contained in equal
volumes.
\item High-dielectric stress generated by rapidly changing rectangular voltage waveforms.
\item High-isolation levels are required (due to multi-level inverter structure).
\item Generation of acoustic noise, which reaches the most sensitive range of the human ear.
\end{itemize}
\begin{table}[]
\begin{center}
\begin{tabular}{ll}
Line Transformer (50 Hz) & High Frequency Transformer\\
\hline
Core Mass & Skin Effect\\
Copper Losses & Core Losses\\
Volume & Parasitic Capacitance\\
& Cooling \\
& Resonance \\
\hline
\end{tabular}
\end{center}
\caption{Important factors in the design of line frequency and high-frequency transformers.}
\label{important}
\end{table}
\begin{figure}[]
\centering
\includegraphics[scale=0.3]{transformer_volume}
\includegraphics[scale=0.25]{transformer_frequency_commercial_orbitz2010a}
\caption{Volumes of high frequency transformers(normalized to 1 MW) and rated power and operating frequencies of existing DC-DC converter prototypes \cite{Ortiz2010a,Ortiz2010}.}
\label{transformer-vols}
\end{figure}
\section{Core Materials}
Although, silicon or nickel-steel laminations are commonly used in conventional line frequency power transformers, the high loss of these components at high frequencies makes other options more viable. Ferrite is one of the first alternatives in the market, but in he recent years materials like amorphous and nanocrystalline become increasingly popular \cite{Agheb2012}.
\subsection*{Amorphous Materials}
Amorphous cores are typically made of Metglas (metalic glass alloy), which is a thin non-crystalline amorphous metal alloy of iron, boron, silicon and phosphorus. The material has a much higher resistivity in electrical steel which results in a low eddy losses. Furthermore, the hysteresis losses of amorphous cores are lower, which reduces the no-load losses compared to one with electrical steel. However, amorphous materials usually have lower saturation flux density compared to conventional iron-silicon electrical steel.
Some manufacturers of amorphous transformer cores can be listed as:
\begin{itemize}
\item Hitachi Metals (Powerlite)
\item Vacuumschmelze (Vitrovac)
\item Metglas
\item Vijai Electricals
\end{itemize}
Although, amorphous materials are superior to electrical steel laminations, nano-crystalline materials are superior to amorphous materials with their lower cost and higher flux densities \cite{vitroperm_vitrovac}. Nano-crystalline materials will be discussed in the next section. The specifications of amorphous and nano-crystalline materials are compared in Table~\ref{vitropermvitrovac}. The only application that a amorphous material can be more advantageous is high-frequency single-ended forward converter topologies. For all other topologies, nano-crystalline materials are considered to be more suitable.
\begin{table}[]
\begin{center}
\begin{tabular}{lcc}
& Amorphous & Nano-crystalline \\
& (Vitrovac) & (VitroPerm) \\
\hline
Saturation Flux Density & 0.8 T & 1.2 T \\
Losses (f= 20 kHz, B=0.2 T) & 2 W/kg & 1.4 W/kg \\
Max. Operating temperature & $110\,^{\circ}\mathrm{C}$ & $120\,^{\circ}\mathrm{C}$ \\
Curie temperature & $365\,^{\circ}\mathrm{C}$ & $600\,^{\circ}\mathrm{C}$ \\
\hline
\end{tabular}
\end{center}
\caption{Comparison of amorphous (Vitrovac) and nano-crystalline (VitroPerm) materials \cite{vitroperm_vitrovac}.}
\label{vitropermvitrovac}
\end{table}
\subsection*{Nano-crystalline}
Nano-crystalline is a fairly new material that consists of approximately 80\% of iron with the remaining is mixture of silicon, boron, carbon, nickel and other materials. This is a special type of amorphous material, which has superior magnetic characteristics, such as lower core loss and high permeability. Other specifications can be listed as \cite{Magnetics}:
\begin{itemize}
\item Up to 50 \% permeability than 80\% nickel material (e.g. Supermalloy).
\item High saturation flux density (1.2-1.5 T).
\item High operating temperature up to $130\,^{\circ}\mathrm{C}$.
\item Minimal change of magnetic characteristics with temperature.
\item 17 \% lighter than Nickel with a density of 7.3 $\mathrm{g/cm^3}$.
\item Stacking density up to 90 \% can be achieved.
\end{itemize}
Some main manufacturers of nano-crystalline materials can be listed as:
\begin{itemize}
\item MK Magnetics
\item Vacuumschmelze
\item Hill-Tech
\end{itemize}
In this section, different types of nano-crystalline materials will be compared.
Vacuumschmelze manufactures various soft magnetic nano-crystalline materials under the brand of VitroPerm.
\subsubsection*{VitroPerm}
Nanocrystalline VitroPerm alloys are based on Fe with Si and B with Nb and Cu additives \cite{vitroterm_manual}. VitroPerm nano-crystalline alloys are optimized to combine highest permeability and lowest coercive field strength. The combination of very thin tapes and the relatively high electrical resistance (1.1-1.2~$\mu \Omega m$) to ensure minimal eddy current losses and an outstanding frequency vs. permeability behaviour. Along with saturation flux density of 1.2 T and wide operational temperature range, these features combine to make VitroPerm superior in many aspects to commonly used ferrite and amorphous materials. Magnetization curves and B-H characteristics of VitroPerm materials are presented in Fig.~\ref{vitroterm_BH}.
\begin{figure}[]
\centering
\includegraphics[scale=0.3]{vitroperm_magnetization}
\includegraphics[scale=0.3]{vitroterm_hysteresis}
\caption{Magnetisation curve and B-H characteristics of VitroPerm \cite{vitroterm_manual}.}
\label{vitroterm_BH}
\end{figure}
VitroPerm has a wide range material options with different permeability scale as as shown in Fig.~\ref{vitroterm_permeability}.
The permeability of VitroPerm 500F is significantly higher than ferrite as shown in Fig.~\ref{vitroperm500_250_permeability}.
\begin{figure}[]
\centering
\includegraphics[scale=0.3]{vitroterm_permeability}
\caption{Permeability change of different VitroPerm materials with frequency \cite{vitroperm_toroidal}.}
\label{vitroterm_permeability}
\end{figure}
\begin{figure}[]
\centering
\includegraphics[scale=0.3]{vitroperm500_250_permeability}
\caption{Permeability change of VitroPerm 250F($\mu = 5000$), VitroPerm 500F($\mu = 40000$) and ferrite($\mu = 5000$) with frequency. \cite{vitroterm_manual}.}
\label{vitroperm500_250_permeability}
\end{figure}
VitroPerm has also a high operating temperature compared to ferrite. The Curie temperature of VitroPerm alloys are $600\,^{\circ}\mathrm{C}$. Furthermore, the saturation flux density only reduces by 10\% at $120\,^{\circ}\mathrm{C}$, which allows the core can be overloaded for short-amount of periods up to $180-200 \,^{\circ}\mathrm{C}$. The variation of permeability with temperature for VitroPerm is presented in Fig.~\ref{temp_vs_saturation}.
\begin{figure}[]
\centering
\includegraphics[scale=0.3]{temp_vs_saturation}
\caption{Saturation flux density variation of VitroPerm with temperature.}
\label{temp_vs_saturation}
\end{figure}
\subsection*{Silicon-Steel}
Silicon-steel is a popular choice in line frequency power transformers for its low cost and high-saturation magnetic induction. However, core losses of silicon-steel is high compared to other materials, which makes them unsuitable for medium frequency transformers. The core losses of material will be compared in the next section.
\subsection*{Ferrites}
Ferrites have a low-loss density in very high-frequencies, which makes them a suitable material for high-frequency applications such as RF-filters and chokes. However, they have saturation flux density around 0.5 T, which increases the core volume and mass in high power applications.
\subsection*{Core Material Comparison}
Different core materials and manufacturers are presented in Table~\ref{core-loss-table}. In Fig.~\ref{material_table}, prototypes with common core materials are presented. It can be seen from the table that nano-crystalline and amorphous materials are the most suggested materials for medium frequency transformers that work between 1 kHz and 25 kHz.
\begin{table}[]
\begin{center}
\begin{tabular}{llccl}
Material & Brand & Saturation Flux & Core Loss & Manufacturer \\
\hline
& Microlite & 1.56 T & 1.5 kW/kg & Metglas\\
Amorphous & Powerlite & 1.56 T & 0.6 kW/kg & Metglas\\
& Namglass & 1.59 T & 0.34 kW/kg & Magmet\\
& Vitrovac & 0.82 T & 0.19 kW/kg & VAC\\
\hline
& Finemet & 1.23 T & 0.14 kW/kg & Hitachi\\
Nano-crystalline& VitroPerm & 1.2 T & 0.07 kW/kg & VAC\\
& Nanoperm & 1.2 T & 0.04 kW/kg & Magnetec\\
& Namglass 4 & 1.23 T & 0.04 kW/kg & Magmet\\
\hline
Silicon Steel & Arnon 7 & 1.53 T & 1.6 kW/kg & Arnold\\
& Arnon 5 & 1.48 T & 1.06 kW/kg & Arnold\\
\hline
\end{tabular}
\end{center}
\caption{Core materials and manufacturers for high-frequency transformers (specific losses at B = 1 T, f = 20 kHz) \cite{Ortiz2010}.}
\label{core-loss-table}
\end{table}
\begin{figure}[]
\centering
\includegraphics[]{material_table_villar_2010}
\caption{Common materials used in medium frequency transformers and previous prototypes (Heinemann, 2002:\cite{Heinemann2002}, Steiner,2007:\cite{Steiner2007}, Pavlovsky,2005:\cite{Pavlovsky2005}, Morren,2002:\cite{Morren2002}, Prasai,2007:\cite{Prasai2007}) \cite{Villar2010}.}
\label{material_table}
\end{figure}
The hysteresis losses and the core loss of different materials are compared in Fig.~\ref{core-loss}. Core losses are presented in Fig.~\ref{core-loss-log}. It can be seen that between 1 kHz and 10 kHz, the core loss of 0.3 mm silicon-steel laminations are 25 times higher than nano-crystalline material.
A 50 kV, high frequency (20 kHz), 150 kW transformer that uses nano-crystalline material is presented in \cite{Filchev2009}, in which the core losses are estimated as 60W/kg at an operating flux density of 1 T.
\begin{figure}[]
\centering
\includegraphics[scale=0.3]{hysteresis-losses}
\includegraphics[scale=0.3]{core-loss}
\caption{Loss comparison of silicon-steel, amorphous, nano-crystalline and ferrite materials \cite{Villar2010}. a) Hysteresis loss, b) Core loss.}
\label{core-loss}
\end{figure}
\begin{figure}[]
\centering
\includegraphics[scale=0.3]{vitroperm_core_losses_vs_freq}
\caption{Core loss comparison of nano-crystalline (VitroPerm) with electrical steel and amorphous material \cite{vitroterm_manual}.}
\label{core-loss-log}
\end{figure}
\section{Losses in a Transformer}
There are many analytical models to calculate the losses of medium frequency transformers. These methods, for different transformers types are reviewed in \cite{Agheb2012} and in \cite{Villar2010}.
\subsection{AC Winding Losses}
The high frequency excitation in a medium frequency transformer has two main effects in the transformer windings:
\begin{itemize}
\item Skin Effect: In AC excitation the current itself generates an opposing magnetic field and current, which reduce the net current density inside the conductor. The total current will stay same, but the distribution will be higher across the circumference of the conductor.
\item Proximity Effect is the interaction between two adjacent conductors that alters the current distribution in the conductor. Same principles(e.g. proximity, frequency) apply in the proximity affect.
\end{itemize}
Losses due to skin effect decrease by increasing the foil thickness whereas proximity effect losses increase with increasing foil thickness \cite{Ortiz2010}.
\subsubsection{Skin Effect}
Skin effect is an important factor in AC resistance and eddy current losses in a transformer. Skin effect is effected by the skin depth, which can be expressed as:
\begin{equation}
\sigma = \sqrt{\frac{2\rho}{\mu \omega}}
\end{equation}
where $\rho$ is the resistivity of the conductor, $\mu$ is permeability, and $\omega$ is the frequency in rad/s. Skin depth of copper for different operating frequencies are presented in Table~\ref{skin-depth}. For reasonable AC resistance characteristics, the rule of thumb is to choose the conductor diameter smaller than 1.6 times of the skin depth. Thus, for a 1-2 kHz transformer application, the conductor should not be thicker than 2-3 mm.
\begin{table}[]
\begin{center}
\begin{tabular}{cc}
Frequency & Skin Depth \\
\hline
50 Hz & 9.2 mm \\
1 kHz & 2.06 mm \\
2 kHz & 1.49 mm \\
5 kHz & 0.94 mm \\
10 kHz & 0.65 mm \\
50 kHz & 0.29 mm \\
\hline
\end{tabular}
\end{center}
\caption{Skin depth in a copper conductor.}
\label{skin-depth}
\end{table}
In a step-up transformer the cross-section area of the primary conductor will be larger. However, the limit due to skin-depth limits the thickness of the conductor. Therefore, the most feasible way is to use foil conductors in the primary windings.
Dowell calculated eddy losses in foil type transformer windings in \cite{Dowell1966}. A detailed explanation of these one dimensional Maxwell equations can be found in \cite{Villar2010} and a summary will be presented in this section.
The DC resistance of a foil winding can be expressed as:
\begin{equation}
R_{dc} = \rho \frac{L_{mean}}{t_w h_w} N_{turns}
\end{equation}
where $L_{mean}$ is the mean turn length of the coil, $t_w$ is the thickness, $h_w$ is the height, $\rho$ is the resistivity of copper.
The AC resistance is more complicated to calculate and depends on the ratio of the wire thickness to skin depth ($\delta$) and can be expressed as:
\begin{equation}
R_{ac}=\rho \frac{L_{mean}}{h_w \delta} N_{turns} \left[\varsigma_1 + \frac{2}{3} (N_{turns}^2-1)\varsigma_2\right]
\label{R_ac_foil}
\end{equation}
where:
\begin{equation}
\varsigma_1 = \dfrac{sinh(2\Delta)+sin(2\Delta)}{cosh(2\Delta)-cos(2\Delta)} \quad
\varsigma_2 = \dfrac{sinh(\Delta)-sin(\Delta)}{cosh(\Delta)+cos(\Delta)} \quad
\Delta = \dfrac{t_w}{\delta}
\end{equation}
as can be seen from the equation above, the important factor is the penetration factor (i.e the ratio of conductor thickness to skin depth, $\Delta$). The ratio of AC resistance to DC resistance is called Dowell's resistance factor ($F_r$). The resistance factor as a function of penetration ratio for a 2 mm thick foil wire is presented in Fig.~\ref{resistance_factor}. For example, at 1 kHz the skin depth is 2.1 mm (the penetration ratio is approximately 1), the resistance factor is 2.7 for a layer number of 4. Thus the resistive losses will be 2.7 times more compared to DC conduction.
\begin{figure}[]
\centering
\includegraphics[scale=1.25]{resistance_factor}
\caption{Resistance factor for a function of penetration ratio (for 2 mm thick foil conductor) \cite{Villar2010}.}
\label{resistance_factor}
\end{figure}
\subsubsection{Secondary-Winding}
There are different analytical models to estimate the AC resistances of round conductors (e.g. high voltage cables that can be used in the secondary winding), such as presented in \cite{Sullivan2003,Ferreira1994}. Although, the method presented by Dowell in \cite{Dowell1966} is assumed as the most established method. In this method Dowell introduced a porosity factor to convert the round conductors to square conductors and then convert to foil type conductors.
Equivalent thickness of a round conductor can be defined as \cite{Dowell1966}:
\begin{equation}
d_w = \sqrt{\frac{\pi}{4}} d
\end{equation}
where $d$ is the diameter of the round conductor and $d_w$ is the thickness of the equivalent square conductor. Then, similar technique can be applied to convert square conductor to foil type conductor using a second porosity factor as shown in \cite{Villar2010}. Therefore, the AC resistance of the round conductor can be expressed similarly to equation (\ref{R_ac_foil})) as given in \cite{Villar2010}.
\section{Core Losses}
The core losses mainly depend on the material type, flux density and operating frequency. Although, there are many methods to estimate the core losses as reviewed in \cite{Shen2006}, the most common method is to use a power equation, which is known as the Steinmetz equation:
\begin{equation}
P_{core} = K f^a B^b
\end{equation}
where $f$ is the operating frequency, $B$ is peak magnetic flux density, $K$, $a$ and $b$ are factors determined by the material characteristic obtained from the manufacturer's data.
Steinmetz equation is usually well established method for line transformers, in which sinusoidal excitation is used. However, in the medium-high frequency transformers, the transformer is excited using power electronics (usually a square waveform, or stepped waveform), and transformer voltage and current include many harmonics.
\subsection{Core Losses in Non-Sinusoidal Excitation}
Various methods are developed to model the core losses under non-sinusoidal excitation \cite{Venkatachalam2002,Reinert2001}. Some of the methods reviewed in \cite{Villar2010} can be listed as:
\begin{itemize}
\item Modified Steinmetz Equation
\item Improved Generalized Steinmetz Equation
\item Equivalent Elliptical Loop
\item Waveform Coefficient Steinmetz Equation
\end{itemize}
In \cite{Venkatachalam2002}, a model has been developed to predict the non-sinusoidal excitation losses using just the standard Steinmetz parameters. The model calculates the total loss by adding the losses in major and minor loops in the voltage waveform.
Although these methods can provide more accurate results compared to Fourier transform method, they all require extra measurement steps to determine the material characteristics at different operating frequencies and waveforms. Therefore, it is impractical to use these models without experimental study at first. Therefore, using standard Steinmetz equation with harmonics contents is an ideal choice for analytical core loss estimation.
For non-sinusoidal waveforms, the easiest way to calculate the core losses is to use Fourier transform to get the frequency components and then to estimate individual core losses for each component.
The transformer developed by Narec will be excited using a square waveform in the low voltage side, and a multi-level inverter will be used in the high voltage side.
The core losses resulting from the low-voltage square wave excitation can be calculated by expressing the square wave as a Fourier series:
\begin{equation}
f(x) = \frac{4}{\pi} \sum_{n=1,3,5...}^{+\infty} \frac{1}{n} sin ( n \omega x )
\end{equation}
where $\omega$ is the frequency of the square waveform in radians/s, $n$ is the harmonic order. The magnitudes of the Fourier series components of the square wave relative to the magnitude of the square wave is presented in Table~\ref{square_harmonics}.
\begin{table}[]
\begin{center}
\begin{tabular}{ll}
Harmonic Order & Magnitude\\
\hline
1 & 1.273\\
3 & 0.424 \\
5 & 0.254 \\
7 & 0.182 \\
9 & 0.141 \\
11 & 0.116 \\
13 & 0.098 \\
\hline
\end{tabular}
\end{center}
\caption{Fourier series magnitudes relative to the magnitude of the square wave.}
\label{square_harmonics}
\end{table}
\section{Modeling of the Transformer}
A Matlab model is developed to estimate the transformer models and calculate copper and core losses. The design methodology used in the Matlab code is depicted in Fig.~\ref{design_method}.
\begin{figure}[]
\centering
\includegraphics[scale=0.4]{design_method}
\caption{Design methodology to estimate transformer parameters and losses.}
\label{design_method}
\end{figure}
\subsection{Estimation of Winding Parameters}
It is assumed from the WP 2 report that, foil type conductors are the most suitable option for the low voltage side. On the high voltage side, circular stranded cables are more suitable with their mechanical strength and increased dielectric insulation. It is stated in \cite{Morren2002} that, using standard high-voltage cables has advantages such as: elimination of oil insulation, and better distribution of electric field in round conductors.
The thickness of the coil is chosen according to the skin depth at the operating frequency. The conductor thickness is selected to be less than 1.5 times skin depth, however, actual foil conductor thickness is limited to standard wire gauges (e.g. 1 mm, 1.6 mm, 2 mm, 2.25 mm...). The frequency of the transformer versus the most suitable foil coil thickness is plotted in Fig.~\ref{primary_thickness}. For example, for operating frequencies between 2 kHz and 3 kHz, the most suitable conductor thickness is 2 mm.
\begin{figure}[]
\centering
\includegraphics[]{primary_thickness}
\caption{Skin depth and primary foil winding size variation (Standard foil conductor sizes are used).}
\label{primary_thickness}
\end{figure}
Then, using rated current and the rated current density, the required conductor area can be calculated. The conductor height can be found by dividing the conductor area to conductor thickness. For example, assuming a current density of $4 A/mm^2$, the foil conductor height can be calculated as a function of the operating frequency as shown in Fig.~\ref{primary_height}.
Similar method can be used for the secondary HV winding, where a standard circular HV cable can be used. The standard diameter of these cables are 2.5 mm, 4 mm, 6 mm, 10 mm, 16 mm. More information about HV cables can be found in \cite{HVcable}.
\begin{figure}[]
\centering
\includegraphics[]{primary_height}
\caption{Height of the foil conductor as a function of the operating frequency.}
\label{primary_height}
\end{figure}
Insulation parameters should be known to determine the dimensions of the primary and secondary windings. Dry insulation is considered to be the most suitable insulation type due to increased reliability and ease of manufacturing. However, oil flooded windings can be preferred to improve thermal performance. In Table~\ref{dielectric}, dielectric strengths of some common dry-type insulation materials are presented and typical insulation thickness values are presented in \cite{Ortiz2010}. Although, type of the insulation material is not specified in this report, but it is stated in WP2 report that the most suitable insulation type is potted epoxy. Following insulation thickness values are chosen to calculate AC copper losses. In order to get more accurate results, these values should be modified in the model once the detailed design of the transformer is completed.
\begin{table}[]
\begin{center}
\begin{tabular}{lcc}
Insulation Type & Material & Dielectric Strength\\
\hline
Potted & Epoxy & 16 kV/mm\\
Potted & Micares & 8-24 kV/mm \\
HV Cable & Silicone & 4-28 kV/mm\\
HV Cable & PVC & 10-10 kV/mm\\
HV Cable & HDPE & 19 kV/mm \\
\hline
\end{tabular}
\end{center}
\caption{Dry-type insulation dielectric strengths \cite{Ortiz2010}.}
\label{dielectric}
\end{table}
\begin{itemize}
\item Insulation thickness between primary (low voltage) conductors: 1 mm
\item Insulation thickness from primary winding to core: 10 mm
\item Outer insulation thickness around primary winding: 10 mm
\item Insulation thickness between secondary (high voltage) conductors: 5 mm
\item Insulation thickness from secondary winding to core: 20 mm
\item Outer insulation around secondary winding: 20 mm
\item Insulation thickness between primary and secondary windings: 50 mm
\end{itemize}
\subsection{Estimation of Core Dimensions}
The most important parameter of the core is the cross-section area, which depends on the operating frequency, flux density in the core and the number of turns. Assuming a square cross-section area, the thickness of the core as a function of the primary number of turns is estimated as in Fig.~\ref{core_dimensions}, and similarly graphs for the secondary number of turns are presented in Fig.~\ref{secondary_core_dimensions}. The operating flux density of the core is assumed as 1.1 T, the primary voltage magnitude is assumed as 3 kV, and the secondary voltage magnitude is assumed as 300 kV.
Although, it is not presented in this report, the main dimensions and the mass of the core is calculated in the Matlab models and these figures can be used to estimate the overall weight and cost of the transformer.
\begin{figure}[]
\centering
\includegraphics[]{primary_Nturns_core}
\includegraphics[]{primary_Nturns_freq}
\caption{Core-thickness (assuming square cross-section area) as a function of the primary number of turns and operating frequency (B=1.1 T, Vin=3 kV, Vout=300 kV).}
\label{core_dimensions}
\end{figure}
\begin{figure}[]
\centering
\includegraphics[]{secondary_Nturns_core}
\includegraphics[]{secondary_Nturns_freq}
\caption{Core-thickness (assuming square cross-section area) as a function of the secondary number of turns and operating frequency (B=1.1 T, Vin=3 kV, Vout=300 kV).}
\label{secondary_core_dimensions}
\end{figure}
\section{Sample Design}
In this section, four transformer designs will be presented with different primary number of turns. The initial designs are developed the Matlab model described in the previous section.
The main dimensions in the analytical design are presented in Fig.~\ref{transformer_dimensions}.
\begin{figure}[]
\centering
\includegraphics[width=0.5\textwidth]{transformer_dimensions}
\includegraphics[width=0.45\textwidth]{transformer_dimensions_cross_section}
\caption{Main dimensions of the transformer. a) Side-view, b) Cross section of the core and winding.}
\label{transformer_dimensions}
\end{figure}
Following assumptions are made in the design process:
\begin{itemize}
\item Operating Frequency: 1 kHz
\item Core Material: Vitroperm 500F
\item Operating Flux Density: 1.1 T (90\% of the saturation flux density)
\item Operating Temp: 110 C (for resistance calculations)
\item Current Density: 4 A/mm$^2$ (in the conductor).
\item Permeability: $\mu = 30000$
\item Core Type: C-core with square cross-section.
\item LV Coil Type: Foil type conductor. The thickness is calculated considering eddy current loss as described in the previous section.
\item HV Coil Type: Round insulated HV cable.
\item Inner Insulation Thickness(Insulation between winding and the core): 6 mm for the low-voltage side, 20 mm for the high-voltage side.
\item Outer Insulation Thickness: 10 mm for the low-voltage side, 20 mm for the high-voltage side.
\item Insulation Thickness Between Conductors: 1 mm for the primary coil, 5 mm for the secondary.
\item Gap Between LV and HV Winding: 50 mm
\end{itemize}
In this report, four transformer designs are presented with varying primary(low-voltage) number of turns:
\begin{itemize}
\item Design A: $Nturns_{LV}=5$
\item Design B: $Nturns_{LV}=8$
\item Design C: $Nturns_{LV}=12$
\item Design D: $Nturns_{LV}=15$
\end{itemize}
\begin{figure}[]
\centering
\includegraphics[width=0.45\textwidth]{Np5}
\includegraphics[width=0.45\textwidth]{Np8_pers}
a) Nturn$_{LV}$=5 \hspace{1.1in} b) Nturn$_{LV}$=8
\includegraphics[width=0.45\textwidth]{N12}
\includegraphics[width=0.45\textwidth]{N15}
a) Nturn$_{LV}$=12 \hspace{1.1in} b) Nturn$_{LV}$=15
\caption{Opera models of transformers with varying LV number of turns.}
\label{trans_images}
\end{figure}
The FEA models of the designs are presented in Fig.~\ref{trans_images}, and the specifications of these designs are presented through Table~\ref{design_A} to Table~\ref{design_D}. Table~\ref{conductor_length} compares the core mass, conductor length (for the LV and HV windings).
From the table, following can be concluded:
\begin{itemize}
\item Core mass reduces as the number of turns increases.
\item The length of both windings increase with number of turns. However, increase in the HV winding length is more significant compared to the LV winding. For example, when primary number of turns is increased from 5 to 15, the length of the LV winding just doubles, however, the length of HV winding quadruples, which makes the losses in the HV side more dominant. This is due to thick insulation around the HV cable and high number of turns.
\item Assuming the core loss is proportional to core mass and the copper loss is proportional to conductor length, the core loss reduces with increasing number of turns, whereas the copper loss increases with increasing number of turns.
\end{itemize}
Based on the initial models, the optimum number of turns for the primary winding is selected as 8, and more detailed FEA simulations are performed. FEA simulations are performed with Opera 3D software and the scripts that are used to model the transformer are available in the project folder.
Fig.~\ref{Np8_FEA} shows the FEA model and magnetic flux distribution for Design-B($Nturns_{LV}=8$). Flux density vectors are shown in Fig.~\ref{Np8_FEA}(b). The distribution in the core cross-section area is presented in Fig.~\ref{Np8_FEA}(c) and Fig.~\ref{Np8_FEA}(d). These figures show that the distribution of the magnetic flux is quite homogeneous at the operating magnetic flux magnitude. Thus, analytical core loss models, which are presented in the previous sections, can also be used with enough accuracy, if required.
\begin{table}[]
\begin{center}
\begin{tabular}{lcccc}
& $Nturns_{LV}$ & LV Winding & HV Winding & Core Mass \\
\hline
Design A & 5 & 8.3 m & 1159 m & 2477 kg \\
Design B & 8 & 11.0 m & 1889 m & 1500 kg \\
Design C & 12 & 14.4 m & 3146 m & 1037 kg \\
Design D & 15 & 17.0 m & 4358 m & 877 kg \\
\hline
\end{tabular}
\end{center}
\caption{Variation of conductor length and core mass with number of turns.}
\label{conductor_length}
\end{table}
\begin{table}[]
\begin{center}
\begin{tabular}{lc}
Primary(LV) & Nturns=5\\
\hline
Coil Height & 172 mm \\
Total Height & 192 mm \\
Coil Thickness & 3.15 mm\\
Winding Width & 20.75 \\
R$_{in}$ & 254 mm \\
R$_{out}$ & 285 mm \\
Mean Length & 1662 mm \\
AC Resistance & 0.0034 $\Omega$ \\
\hline
Secondary (HV) \\
Coil Area & 6 mm$^2$\\
Winding Height & 152 mm \\
Total Height & 192 mm \\
Ncoil horizontal & 25 \\
Ncoil vertical & 20 \\
Winding Width & 202 mm \\
R$_{in}$ & 268 mm \\
R$_{out}$ & 490 mm \\
Mean Length & 2319 mm \\
\hline
Core \\
Thickness & 351 mm \\
Cross Section & 0.1228 m$^2$\\
Horizontal Gap & 474 mm \\
Vertical Gap & 192 mm \\
Height & 894 mm \\
Width & 1176 mm \\
Volume & 0.337 m$^3$ \\
Mass & 2477 kg \\
\hline
Approx. Core Loss & 867 W (1 kHz) \\
\hline
\end{tabular}
\end{center}
\caption{Design-A ($Nturns_{LV}=5$) winding and core parameters.}
\label{design_A}
\end{table}
\begin{table}[]
\begin{center}
\begin{tabular}{lc}
Primary (LV) & Nturns=8\\
\hline
Coil Height & 172 mm \\
Total Height & 192 mm \\
Coil Thickness & 3.15 mm\\
Winding Width & 33 mm \\
R$_{in}$ & 202 mm \\
R$_{out}$ & 245 mm \\
Mean Length & 1377 mm \\
AC Resistance & 0.011 $\Omega$ \\
\hline
Secondary (HV) \\
Coil Area & 6 mm$^2$\\
Winding Height & 152 mm \\
Total Height & 192 mm \\
Ncoil horizontal & 40 \\
Ncoil vertical & 20 \\
Winding Width & 318 mm \\
R$_{in}$ & 216.5 mm \\
R$_{out}$ & 555 mm \\
Mean Length & 2361 mm \\
\hline
Core \\
Thickness & 278 mm \\
Cross Section & 0.0767 m$^2$\\
Horizontal Gap & 572 mm \\
Vertical Gap & 192 mm \\
Height & 748 mm \\
Width & 1148 mm \\
Volume & 0.204 m$^3$ \\
Mass & 1500 kg \\
\hline
Approx. Core Loss & 525 W (1 kHz) \\
\hline
\end{tabular}
\end{center}
\caption{Design-B ($Nturns_{LV}=8$) winding and core parameters.}
\label{design_B}
\end{table}
\begin{table}[]
\begin{center}
\begin{tabular}{lc}
Primary (LV) & Nturns=12\\
\hline
Coil Height & 172 mm \\
Total Height & 192 mm \\
Coil Thickness & 3.15 mm\\
Winding Width & 50 mm \\
R$_{in}$ & 166.5 mm \\
R$_{out}$ & 226 mm \\
Mean Length & 1202 mm \\
AC Resistance & 0.0323 $\Omega$ \\
\hline
Secondary (HV) \\
Coil Area & 6 mm$^2$\\
Winding Height & 152 mm \\
Total Height & 192 mm \\
Ncoil horizontal & 60 \\
Ncoil vertical & 20 \\
Winding Width & 473 mm \\
R$_{in}$ & 180.5 mm \\
R$_{out}$ & 674 mm \\
Mean Length & 2622 mm \\
\hline
Core \\
Thickness & 227 mm \\
Cross Section & 0.0512 m$^2$\\
Horizontal Gap & 572 mm \\
Vertical Gap & 192 mm \\
Height & 646 mm \\
Width & 1177 mm \\
Volume & 0.141 m$^3$ \\
Mass & 1037 kg \\
\hline
Approx. Core Loss & 363 W (1 kHz) \\
\hline
\end{tabular}
\end{center}
\caption{Design-C ($Nturns_{LV}=12$) winding and core parameters.}
\label{design_C}
\end{table}
\begin{table}[]
\begin{center}
\begin{tabular}{lc}
Primary (LV) & Nturns=15\\
\hline
Coil Height & 172 mm \\
Total Height & 192 mm \\
Coil Thickness & 3.15 mm\\
Winding Width & 62.5 mm \\
R$_{in}$ & 149.5 mm \\
R$_{out}$ & 222 mm \\
Mean Length & 1135 mm \\
AC Resistance & 0.0593 $\Omega$ \\
\hline
Secondary (HV) \\
Coil Area & 6 mm$^2$\\
Winding Height & 152 mm \\
Total Height & 192 mm \\
Ncoil horizontal & 75 \\
Ncoil vertical & 20 \\
Winding Width & 597 mm \\
R$_{in}$ & 163 mm \\
R$_{out}$ & 781 mm \\
Mean Length & 2905 mm \\
\hline
Core \\
Thickness & 203 mm \\
Cross Section & 0.0409 m$^2$\\
Horizontal Gap & 850 mm \\
Vertical Gap & 192 mm \\
Height & 598 mm \\
Width & 1256 mm \\
Volume & 0.119 m$^3$ \\
Mass & 877 kg \\
\hline
Approx. Core Loss & 307 W (1 kHz) \\
\hline
\end{tabular}
\end{center}
\caption{Design-D ($Nturns_{LV}=15$) winding and core parameters.}
\label{design_D}
\end{table}
\begin{figure}[]
\centering
\includegraphics[width=0.5\textwidth]{N8_B}
\includegraphics[width=0.49\textwidth]{N8_Bvectors}
a) Meshed model \hspace{1in} b) Flux density vectors in the core.
\includegraphics[width=0.5\textwidth]{N8_core_By}
\includegraphics[width=0.45\textwidth]{N8_core_By3}
c) Flux density distribution in the core cross-section.
\caption{FEA models and flux density distribution in the core (Design-B, $Nturns_{LV}=8$).}
\label{Np8_FEA}
\end{figure}
\clearpage
\section{Core Losses}
Core material is chosen as nano-crystalline (Vitroperm 500), the operating flux density is determined as 1.1 T. In the material manual \cite{Vacuumschmelze2003}, the core losses between 20 kHz and 100 kHz are presented. The loss data between 1 kHz and 10 kHz have been extrapolated using this data and data-sheets of similar materials.
The core loss density variation at 1 T with varying frequency is presented in Table~\ref{core_loss_vs_freq}. In Table~\ref{core_loss_vs_freq_B} core loss variation with frequency and flux density is presented. It can be seen from the table that the core losses increase with the square of the magnitude of the flux density.
\begin{table}[]
\begin{center}
\begin{tabular}{rr}
Frequency & Loss \\
\hline
1 kHz & 0.25 W/kg\\
5 kHz & 4.8 W/kg\\
10 kHz & 17.5 W/kg\\
15 kHz & 37.1 W/kg\\
20 kHz & 63.3 W/kg\\
\hline
\end{tabular}
\end{center}
\caption{Variation of core loss of Vitroperm 500 with frequency at 1 T.}
\label{core_loss_vs_freq}
\end{table}
\begin{table}[]
\begin{center}
\begin{tabular}{rrr}
Frequency(Hz) & Flux Density (T) & Loss density (W/kg) \\
\hline
1000 & 0 & 0 \\
1000 & 0.2 & 0.01 \\
1000 & 0.4 & 0.04 \\
1000 & 0.6 & 0.09 \\
1000 & 0.8 & 0.16 \\
1000 & 1 & 0.25 \\
1000 & 1.2 & 0.35 \\
\hline
2000 & 0 & 0 \\
2000 & 0.2 & 0.04 \\
2000 & 0.4 & 0.14 \\
2000 & 0.6 & 0.32 \\
2000 & 0.8 & 0.56 \\
2000 & 1 & 0.88 \\
2000 & 1.2 & 1.27 \\
\hline
5000 & 0 & 0 \\
5000 & 0.2 & 0.2 \\
5000 & 0.4 & 0.77 \\
5000 & 0.6 & 1.73 \\
5000 & 0.8 & 3.09 \\
5000 & 1 & 4.83 \\
5000 & 1.2 & 6.95 \\
\hline
10000 & 0 & 0 \\
10000 & 0.2 & 0.7 \\
10000 & 0.4 & 2.8 \\
10000 & 0.6 & 6.3 \\
10000 & 0.8 & 11.19 \\
10000 & 1 & 17.48 \\
10000 & 1.2 & 25.17 \\
\hline
\end{tabular}
\end{center}
\caption{Variation of core loss of Vitroperm 500 with frequency and flux density.}
\label{core_loss_vs_freq_B}
\end{table}
\section{Conclusion}
In this report, a review of core materials and loss calculation methods for medium frequency transformers are presented. Analytical and FEA models are also presented (and available in the project folder).
Following conclusions can be drawn from the report:
\textbf{Core Material}: Although electrical steel laminations are commonly used in line frequency transformers, they are not suitable in medium frequency transformers with their increased losses. Ferrites have very low losses, but they also have a very low operating flux density, which makes them unsuitable for high power applications. Nano-crystalline material is considered to be most suitable material with its high flux density and very low losses at high frequencies. Vacuumschmelze's Vitroperm500F is a popular material, that can be used. Amorphous materials can be used to reduce the core mass, as their operating flux densities are 25\% higher than nano-crystalline materials, but they have higher losses.
\textbf{Core Type}: Various transformer core topologies are compared in \cite{Agheb2012}. It is considered that core type transformer is the simplest and easiest to manufacture, and hence the most suitable option as the initial prototype.
\textbf{Winding Type}: In the primary field windings, the most suitable winding type is foil-type conductors, as low thickness is required for minimum eddy current loss, but a large conductor area is required to conduct high input current. It is possible to use two parallel primary windings to double the conducting area. Standard HV cables are proposed to be used in the secondary winding in order to simplify the manufacturing and insulation.Multi-stranded insulated conductors can be used to minimize the eddy current losses as a replacement to Litz wires.
Analytical (Matlab) models are developed to estimate the parameters of the transformer. These parameters are used as an input to finite element models. It is also possible to link these models with more detailed analytical models.
Four transformer designs with primary number of turns varying from 5 to 15 are compared, and it is found that the design with a primary turns ratio of 8 is the most optimum design considering conductor length and core mass. This transformer uses 11 m conductor in the LV winding, and 1889 m HV cable in the secondary winding. The core mass is estimated as 1500 kg.
The core loss is estimated by extrapolating the core loss data presented in the manufacturer's data, which is fed into the FEA models. Core loss for Design-B is estimated as 525 W at 1 kHz (pure sinusoidal excitation). FEA models showed that the magnetic flux distribution in the core is homogeneous, thus the core loss can also be calculated using analytical models. However, in order to get more accurate results, loss characteristics of the transformer core material should be mapped experimentally with varying magnetic flux and operating frequency.
\clearpage
%----------------------------------------------------------------------------------------
% BIBLIOGRAPHY
%----------------------------------------------------------------------------------------
\bibliographystyle{unsrt}
\clearpage
\bibliography{./NAREC}
%----------------------------------------------------------------------------------------
\end{document}