Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathcase33bw.m
299 lines (275 loc) · 13.2 KB
/
case33bw.m
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
function mpc = case33bw
%CASE33BW Power flow data for 33 bus distribution system from Baran & Wu
% Please see CASEFORMAT for details on the case file format.
%
% Data from ...
% M. E. Baran and F. F. Wu, "Network reconfiguration in distribution
% systems for loss reduction and load balancing," in IEEE Transactions
% on Power Delivery, vol. 4, no. 2, pp. 1401-1407, Apr 1989.
% doi: 10.1109/61.25627
% URL: http://doi.org/10.1109/61.25627
%% MATPOWER Case Format : Version 2
mpc.version = '2';
%%----- Power Flow Data -----%%
%% system MVA base
mpc.baseMVA = 100;
%% bus data
% bus_i type Pd Qd Gs Bs area Vm Va baseKV zone Vmax Vmin
mpc.bus = [ %% (Pd and Qd are specified in kW & kVAr here, converted to MW & MVAr below)
1 3 0 0 0 0 1 1 0 12.66 1 1 1;
2 1 100 60 0 0 1 1 0 12.66 1 1.1 0.9;
3 1 90 40 0 0 1 1 0 12.66 1 1.1 0.9;
4 1 120 80 0 0 1 1 0 12.66 1 1.1 0.9;
5 1 60 30 0 0 1 1 0 12.66 1 1.1 0.9;
6 1 60 20 0 0 1 1 0 12.66 1 1.1 0.9;
7 1 200 100 0 0 1 1 0 12.66 1 1.1 0.9;
8 1 200 100 0 0 1 1 0 12.66 1 1.1 0.9;
9 1 60 20 0 0 1 1 0 12.66 1 1.1 0.9;
10 1 60 20 0 0 1 1 0 12.66 1 1.1 0.9;
11 1 45 30 0 0 1 1 0 12.66 1 1.1 0.9;
12 1 60 35 0 0 1 1 0 12.66 1 1.1 0.9;
13 1 60 35 0 0 1 1 0 12.66 1 1.1 0.9;
14 1 120 80 0 0 1 1 0 12.66 1 1.1 0.9;
15 1 60 10 0 0 1 1 0 12.66 1 1.1 0.9;
16 1 60 20 0 0 1 1 0 12.66 1 1.1 0.9;
17 1 60 20 0 0 1 1 0 12.66 1 1.1 0.9;
18 1 90 40 0 0 1 1 0 12.66 1 1.1 0.9;
19 1 90 40 0 0 1 1 0 12.66 1 1.1 0.9;
20 1 90 40 0 0 1 1 0 12.66 1 1.1 0.9;
21 1 90 40 0 0 1 1 0 12.66 1 1.1 0.9;
22 1 90 40 0 0 1 1 0 12.66 1 1.1 0.9;
23 1 90 50 0 0 1 1 0 12.66 1 1.1 0.9;
24 1 420 200 0 0 1 1 0 12.66 1 1.1 0.9;
25 1 420 200 0 0 1 1 0 12.66 1 1.1 0.9;
26 1 60 25 0 0 1 1 0 12.66 1 1.1 0.9;
27 1 60 25 0 0 1 1 0 12.66 1 1.1 0.9;
28 1 60 20 0 0 1 1 0 12.66 1 1.1 0.9;
29 1 120 70 0 0 1 1 0 12.66 1 1.1 0.9;
30 1 200 600 0 0 1 1 0 12.66 1 1.1 0.9;
31 1 150 70 0 0 1 1 0 12.66 1 1.1 0.9;
32 1 210 100 0 0 1 1 0 12.66 1 1.1 0.9;
33 1 60 40 0 0 1 1 0 12.66 1 1.1 0.9;
];
%% generator data
% bus Pg Qg Qmax Qmin Vg mBase status Pmax Pmin Pc1 Pc2 Qc1min Qc1max Qc2min Qc2max ramp_agc ramp_10 ramp_30 ramp_q apf
mpc.gen = [
1 0 0 10 -10 1.0 100 1 10 0 0 0 0 0 0 0 0 0 0 0 0;
];
%% branch data
% fbus tbus r x b rateA rateB rateC ratio angle status angmin angmax
mpc.branch = [ %% (r and x specified in ohms here, converted to p.u. below)
1 2 0.0922 0.0470 0 0 0 0 0 0 1 -360 360;
2 3 0.4930 0.2511 0 0 0 0 0 0 1 -360 360;
3 4 0.3660 0.1864 0 0 0 0 0 0 1 -360 360;
4 5 0.3811 0.1941 0 0 0 0 0 0 1 -360 360;
5 6 0.8190 0.7070 0 0 0 0 0 0 1 -360 360;
6 7 0.1872 0.6188 0 0 0 0 0 0 1 -360 360;
7 8 0.7114 0.2351 0 0 0 0 0 0 1 -360 360;
8 9 1.0300 0.7400 0 0 0 0 0 0 1 -360 360;
9 10 1.0440 0.7400 0 0 0 0 0 0 1 -360 360;
10 11 0.1966 0.0650 0 0 0 0 0 0 1 -360 360;
11 12 0.3744 0.1238 0 0 0 0 0 0 1 -360 360;
12 13 1.4680 1.1550 0 0 0 0 0 0 1 -360 360;
13 14 0.5416 0.7129 0 0 0 0 0 0 1 -360 360;
14 15 0.5910 0.5260 0 0 0 0 0 0 1 -360 360;
15 16 0.7463 0.5450 0 0 0 0 0 0 1 -360 360;
16 17 1.2890 1.7210 0 0 0 0 0 0 1 -360 360;
17 18 0.7320 0.5740 0 0 0 0 0 0 1 -360 360;
2 19 0.1640 0.1565 0 0 0 0 0 0 1 -360 360;
19 20 1.5042 1.3554 0 0 0 0 0 0 1 -360 360;
20 21 0.4095 0.4784 0 0 0 0 0 0 1 -360 360;
21 22 0.7089 0.9373 0 0 0 0 0 0 1 -360 360;
3 23 0.4512 0.3083 0 0 0 0 0 0 1 -360 360;
23 24 0.8980 0.7091 0 0 0 0 0 0 1 -360 360;
24 25 0.8960 0.7011 0 0 0 0 0 0 1 -360 360;
6 26 0.2030 0.1034 0 0 0 0 0 0 1 -360 360;
26 27 0.2842 0.1447 0 0 0 0 0 0 1 -360 360;
27 28 1.0590 0.9337 0 0 0 0 0 0 1 -360 360;
28 29 0.8042 0.7006 0 0 0 0 0 0 1 -360 360;
29 30 0.5075 0.2585 0 0 0 0 0 0 1 -360 360;
30 31 0.9744 0.9630 0 0 0 0 0 0 1 -360 360;
31 32 0.3105 0.3619 0 0 0 0 0 0 1 -360 360;
32 33 0.3410 0.5302 0 0 0 0 0 0 1 -360 360;
];
%%----- OPF Data -----%%
%% generator cost data
% 1 startup shutdown n x1 y1 ... xn yn
% 2 startup shutdown n c(n-1) ... c0
mpc.gencost = [
2 0 0 3 0 20 0;
];
%% convert branch impedances from Ohms to p.u.
[PQ, PV, REF, NONE, BUS_I, BUS_TYPE, PD, QD, GS, BS, BUS_AREA, VM, ...
VA, BASE_KV, ZONE, VMAX, VMIN, LAM_P, LAM_Q, MU_VMAX, MU_VMIN] = idx_bus;
[F_BUS, T_BUS, BR_R, BR_X, BR_B, RATE_A, RATE_B, RATE_C, ...
TAP, SHIFT, BR_STATUS, PF, QF, PT, QT, MU_SF, MU_ST, ...
ANGMIN, ANGMAX, MU_ANGMIN, MU_ANGMAX] = idx_brch;
Vbase = mpc.bus(1, BASE_KV) * 1e3; %% in Volts
Sbase = mpc.baseMVA * 1e6; %% in VA
mpc.branch(:, [BR_R BR_X]) = mpc.branch(:, [BR_R BR_X]) / (Vbase^2 / Sbase);
%% convert loads from kW to MW
mpc.bus(:, [PD, QD]) = mpc.bus(:, [PD, QD]) / 1e3;
function [PQ, PV, REF, NONE, BUS_I, BUS_TYPE, PD, QD, GS, BS, BUS_AREA, VM, ...
VA, BASE_KV, ZONE, VMAX, VMIN, LAM_P, LAM_Q, MU_VMAX, MU_VMIN] = idx_bus
%IDX_BUS Defines constants for named column indices to bus matrix.
% Example:
%
% [PQ, PV, REF, NONE, BUS_I, BUS_TYPE, PD, QD, GS, BS, BUS_AREA, VM, ...
% VA, BASE_KV, ZONE, VMAX, VMIN, LAM_P, LAM_Q, MU_VMAX, MU_VMIN] = idx_bus;
%
% Some examples of usage, after defining the constants using the line above,
% are:
%
% Pd = bus(4, PD); % get the real power demand at bus 4
% bus(:, VMIN) = 0.95; % set the min voltage magnitude to 0.95 at all buses
%
% The index, name and meaning of each column of the bus matrix is given
% below:
%
% columns 1-13 must be included in input matrix (in case file)
% 1 BUS_I bus number (positive integer)
% 2 BUS_TYPE bus type (1 = PQ, 2 = PV, 3 = ref, 4 = isolated)
% 3 PD Pd, real power demand (MW)
% 4 QD Qd, reactive power demand (MVAr)
% 5 GS Gs, shunt conductance (MW demanded at V = 1.0 p.u.)
% 6 BS Bs, shunt susceptance (MVAr injected at V = 1.0 p.u.)
% 7 BUS_AREA area number, (positive integer)
% 8 VM Vm, voltage magnitude (p.u.)
% 9 VA Va, voltage angle (degrees)
% 10 BASE_KV baseKV, base voltage (kV)
% 11 ZONE zone, loss zone (positive integer)
% 12 VMAX maxVm, maximum voltage magnitude (p.u.)
% 13 VMIN minVm, minimum voltage magnitude (p.u.)
%
% columns 14-17 are added to matrix after OPF solution
% they are typically not present in the input matrix
% (assume OPF objective function has units, u)
% 14 LAM_P Lagrange multiplier on real power mismatch (u/MW)
% 15 LAM_Q Lagrange multiplier on reactive power mismatch (u/MVAr)
% 16 MU_VMAX Kuhn-Tucker multiplier on upper voltage limit (u/p.u.)
% 17 MU_VMIN Kuhn-Tucker multiplier on lower voltage limit (u/p.u.)
%
% additional constants, used to assign/compare values in the BUS_TYPE column
% 1 PQ PQ bus
% 2 PV PV bus
% 3 REF reference bus
% 4 NONE isolated bus
%
% See also DEFINE_CONSTANTS.
% MATPOWER
% Copyright (c) 1996-2016, Power Systems Engineering Research Center (PSERC)
% by Ray Zimmerman, PSERC Cornell
%
% This file is part of MATPOWER.
% Covered by the 3-clause BSD License (see LICENSE file for details).
% See http://www.pserc.cornell.edu/matpower/ for more info.
%% define bus types
PQ = 1;
PV = 2;
REF = 3;
NONE = 4;
%% define the indices
BUS_I = 1; %% bus number (1 to 29997)
BUS_TYPE = 2; %% bus type (1 - PQ bus, 2 - PV bus, 3 - reference bus, 4 - isolated bus)
PD = 3; %% Pd, real power demand (MW)
QD = 4; %% Qd, reactive power demand (MVAr)
GS = 5; %% Gs, shunt conductance (MW at V = 1.0 p.u.)
BS = 6; %% Bs, shunt susceptance (MVAr at V = 1.0 p.u.)
BUS_AREA = 7; %% area number, 1-100
VM = 8; %% Vm, voltage magnitude (p.u.)
VA = 9; %% Va, voltage angle (degrees)
BASE_KV = 10; %% baseKV, base voltage (kV)
ZONE = 11; %% zone, loss zone (1-999)
VMAX = 12; %% maxVm, maximum voltage magnitude (p.u.) (not in PTI format)
VMIN = 13; %% minVm, minimum voltage magnitude (p.u.) (not in PTI format)
%% included in opf solution, not necessarily in input
%% assume objective function has units, u
LAM_P = 14; %% Lagrange multiplier on real power mismatch (u/MW)
LAM_Q = 15; %% Lagrange multiplier on reactive power mismatch (u/MVAr)
MU_VMAX = 16; %% Kuhn-Tucker multiplier on upper voltage limit (u/p.u.)
MU_VMIN = 17; %% Kuhn-Tucker multiplier on lower voltage limit (u/p.u.)
function [F_BUS, T_BUS, BR_R, BR_X, BR_B, RATE_A, RATE_B, ...
RATE_C, TAP, SHIFT, BR_STATUS, PF, QF, PT, QT, MU_SF, MU_ST, ...
ANGMIN, ANGMAX, MU_ANGMIN, MU_ANGMAX] = idx_brch
%IDX_BRCH Defines constants for named column indices to branch matrix.
% Example:
%
% [F_BUS, T_BUS, BR_R, BR_X, BR_B, RATE_A, RATE_B, RATE_C, ...
% TAP, SHIFT, BR_STATUS, PF, QF, PT, QT, MU_SF, MU_ST, ...
% ANGMIN, ANGMAX, MU_ANGMIN, MU_ANGMAX] = idx_brch;
%
% Some examples of usage, after defining the constants using the line above,
% are:
%
% branch(4, BR_STATUS) = 0; % take branch 4 out of service
% Ploss = branch(:, PF) + branch(:, PT); % compute real power loss vector
%
% The index, name and meaning of each column of the branch matrix is given
% below:
%
% columns 1-11 must be included in input matrix (in case file)
% 1 F_BUS f, from bus number
% 2 T_BUS t, to bus number
% 3 BR_R r, resistance (p.u.)
% 4 BR_X x, reactance (p.u.)
% 5 BR_B b, total line charging susceptance (p.u.)
% 6 RATE_A rateA, MVA rating A (long term rating)
% 7 RATE_B rateB, MVA rating B (short term rating)
% 8 RATE_C rateC, MVA rating C (emergency rating)
% 9 TAP ratio, transformer off nominal turns ratio
% 10 SHIFT angle, transformer phase shift angle (degrees)
% 11 BR_STATUS initial branch status, 1 - in service, 0 - out of service
% 12 ANGMIN minimum angle difference, angle(Vf) - angle(Vt) (degrees)
% 13 ANGMAX maximum angle difference, angle(Vf) - angle(Vt) (degrees)
% (The voltage angle difference is taken to be unbounded below
% if ANGMIN < -360 and unbounded above if ANGMAX > 360.
% If both parameters are zero, it is unconstrained.)
%
% columns 14-17 are added to matrix after power flow or OPF solution
% they are typically not present in the input matrix
% 14 PF real power injected at "from" bus end (MW)
% 15 QF reactive power injected at "from" bus end (MVAr)
% 16 PT real power injected at "to" bus end (MW)
% 17 QT reactive power injected at "to" bus end (MVAr)
%
% columns 18-21 are added to matrix after OPF solution
% they are typically not present in the input matrix
% (assume OPF objective function has units, u)
% 18 MU_SF Kuhn-Tucker multiplier on MVA limit at "from" bus (u/MVA)
% 19 MU_ST Kuhn-Tucker multiplier on MVA limit at "to" bus (u/MVA)
% 20 MU_ANGMIN Kuhn-Tucker multiplier lower angle difference limit (u/degree)
% 21 MU_ANGMAX Kuhn-Tucker multiplier upper angle difference limit (u/degree)
%
% See also DEFINE_CONSTANTS.
% MATPOWER
% Copyright (c) 1996-2016, Power Systems Engineering Research Center (PSERC)
% by Ray Zimmerman, PSERC Cornell
%
% This file is part of MATPOWER.
% Covered by the 3-clause BSD License (see LICENSE file for details).
% See http://www.pserc.cornell.edu/matpower/ for more info.
%% define the indices
F_BUS = 1; %% f, from bus number
T_BUS = 2; %% t, to bus number
BR_R = 3; %% r, resistance (p.u.)
BR_X = 4; %% x, reactance (p.u.)
BR_B = 5; %% b, total line charging susceptance (p.u.)
RATE_A = 6; %% rateA, MVA rating A (long term rating)
RATE_B = 7; %% rateB, MVA rating B (short term rating)
RATE_C = 8; %% rateC, MVA rating C (emergency rating)
TAP = 9; %% ratio, transformer off nominal turns ratio
SHIFT = 10; %% angle, transformer phase shift angle (degrees)
BR_STATUS = 11; %% initial branch status, 1 - in service, 0 - out of service
ANGMIN = 12; %% minimum angle difference, angle(Vf) - angle(Vt) (degrees)
ANGMAX = 13; %% maximum angle difference, angle(Vf) - angle(Vt) (degrees)
%% included in power flow solution, not necessarily in input
PF = 14; %% real power injected at "from" bus end (MW) (not in PTI format)
QF = 15; %% reactive power injected at "from" bus end (MVAr) (not in PTI format)
PT = 16; %% real power injected at "to" bus end (MW) (not in PTI format)
QT = 17; %% reactive power injected at "to" bus end (MVAr) (not in PTI format)
%% included in opf solution, not necessarily in input
%% assume objective function has units, u
MU_SF = 18; %% Kuhn-Tucker multiplier on MVA limit at "from" bus (u/MVA)
MU_ST = 19; %% Kuhn-Tucker multiplier on MVA limit at "to" bus (u/MVA)
MU_ANGMIN = 20; %% Kuhn-Tucker multiplier lower angle difference limit (u/degree)
MU_ANGMAX = 21; %% Kuhn-Tucker multiplier upper angle difference limit (u/degree)