forked from victronenergy/dbus-modbus-client
-
Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathshelly.py
138 lines (109 loc) · 3.94 KB
/
shelly.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
import logging
import device
import probe
from register import *
import utils
import time
from copy import copy
log = logging.getLogger(__name__)
class ShellyEnergyMeter(device.EnergyMeter):
def read_register(self, reg):
rr = self.modbus.read_input_registers(reg.base, reg.count,
unit=self.unit)
if rr.isError():
log.info('Error reading register %#04x: %s', reg.base, rr)
raise Exception(rr)
reg.decode(rr.registers)
return reg.value
def read_data_regs(self, regs, d):
now = time.time()
if all((now - r.time < r.max_age) and (now >= r.time) for r in regs):
return
start = regs[0].base
count = regs[-1].base + regs[-1].count - start
rr = self.modbus.read_input_registers(start, count, unit=self.unit)
latency = time.time() - now
if rr.isError():
log.error('Error reading registers %#04x-%#04x: %s',
start, start + count - 1, rr)
raise Exception(rr)
for reg in regs:
base = reg.base - start
end = base + reg.count
if now - reg.time > reg.max_age:
if reg.decode(rr.registers[base:end]) or not reg.time:
if reg.name:
d[reg.name] = copy(reg) if reg.isvalid() else None
reg.time = now
if latency < 0:
return 0
return latency
def get_ident(self):
return 'shelly_{}'.format(self.info['/Serial'])
class ShellyEnergyMeterPro3EM(device.CustomName, ShellyEnergyMeter):
productid = 0xB00D
productname = 'Shelly Pro 3EM'
nr_phases = 3
age_limit_fast = 0.5
fast_regs = (
'/Ac/L1/Power',
'/Ac/L2/Power',
'/Ac/L3/Power',
'/Ac/Power',
'/Ac/L1/Voltage',
'/Ac/L2/Voltage',
'/Ac/L3/Voltage',
'/Ac/L1/Current',
'/Ac/L2/Current',
'/Ac/L3/Current',
)
def device_init(self):
self.info_regs = [
Reg_text(0, 6, '/Serial', little=True)
]
self.read_info();
self.data_regs = [
Reg_f32l(1013, '/Ac/Power', 1, '%.1f W'),
[
Reg_f32l(1020, '/Ac/L1/Voltage', 1, '%.1f V'),
Reg_f32l(1022, '/Ac/L1/Current', 1, '%.1f A'),
Reg_f32l(1024, '/Ac/L1/Power', 1, '%.1f W')
],
[
Reg_f32l(1040, '/Ac/L2/Voltage', 1, '%.1f V'),
Reg_f32l(1042, '/Ac/L2/Current', 1, '%.1f A'),
Reg_f32l(1044, '/Ac/L2/Power', 1, '%.1f W')
],
[
Reg_f32l(1060, '/Ac/L3/Voltage', 1, '%.1f V'),
Reg_f32l(1062, '/Ac/L3/Current', 1, '%.1f A'),
Reg_f32l(1064, '/Ac/L3/Power', 1, '%.1f W')
],
[
Reg_f32l(1162, '/Ac/Energy/Forward', 1000, '%.1f kWh'),
Reg_f32l(1164, '/Ac/Energy/Reverse', 1000, '%.1f kWh')
]
]
class ModelRegisterShelly(probe.ModelRegister):
def probe(self, spec, modbus, timeout=None):
with modbus, utils.timeout(modbus, timeout or self.timeout):
if not modbus.connect():
raise Exception('connection error')
rr = modbus.read_input_registers(self.reg.base, self.reg.count,
unit=spec.unit)
if rr.isError():
log.debug('%s: %s', modbus, rr)
return None
self.reg.decode(rr.registers)
if self.reg.value in self.models:
m = self.models[self.reg.value]
return m['handler'](spec, modbus, m['model'])
models = {
'SPEM-003CEBEU': {
'model': 'SPEM-003CE',
'handler': ShellyEnergyMeterPro3EM
}
}
probe.add_handler(ModelRegisterShelly(Reg_text(6, 10, 'model', little=True), models,
methods=['tcp'],