Entity state class warnings #20
Comments
And also this Logger: homeassistant.components.sensor Entity sensor.p1ib_reactive_power_minus_l1 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using native unit of measurement 'kVAr' which is not a valid unit for the device class ('reactive_power') it is using; expected one of ['var']; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 Entity sensor.p1ib_reactive_power_plus_l2 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using native unit of measurement 'kVAr' which is not a valid unit for the device class ('reactive_power') it is using; expected one of ['var']; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 Entity sensor.p1ib_reactive_power_minus_l2 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using native unit of measurement 'kVAr' which is not a valid unit for the device class ('reactive_power') it is using; expected one of ['var']; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 Entity sensor.p1ib_reactive_power_plus_l3 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using native unit of measurement 'kVAr' which is not a valid unit for the device class ('reactive_power') it is using; expected one of ['var']; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 Entity sensor.p1ib_reactive_power_minus_l3 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using native unit of measurement 'kVAr' which is not a valid unit for the device class ('reactive_power') it is using; expected one of ['var']; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 |
For kVar, It must been added recently (I havent updated my home assistant to latest). Thanks for notifying this. Unit 'var' (or reactive power) have not been available previously. BR, |
I will wait to fix this issue with reactive power, as the unit available/recently added is only "var" (and should be spelled "VAr"), and not kVAr, which is the values that is transmitted from our power meters . kVArh (for reachtive energy) is not either added yet, which is very strange. However I have fixed the first three issues regarding telegram sensor and reactive energy sensor state classes. BR, |
Delivered in development firmware 9c2ad9a (20230922). BR, |
Hi guys Besides the errors above I have also found these: 2024-01-16 22:07:17.062 WARNING (MainThread) [homeassistant.components.sensor] Entity sensor.p1ib_reactive_energy_import_q1_q2 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using native unit of measurement 'kVArh' which is not a valid unit for the device class ('energy') it is using; expected one of ['MWh', 'GJ', 'kWh', 'Wh', 'MJ']; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 2024-01-16 22:07:17.065 WARNING (MainThread) [homeassistant.components.sensor] Entity sensor.p1ib_reactive_energy_export_q3_q4 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using native unit of measurement 'kVArh' which is not a valid unit for the device class ('energy') it is using; expected one of ['MWh', 'GJ', 'kWh', 'Wh', 'MJ']; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22 |
Hi, Please read post :
|
I actually started to do a fork and fixed the issue in HA, but then I didnt have time for a pull request and everything around that. But will have to take care of it at some point as it seems no one else is doing it. |
...and I just realized I actually put the unit kVArh in the wrong place... oh well, some day... :) |
Sorry, I was looking for this: ['MWh', 'GJ', 'kWh', 'Wh', 'MJ'] in the above messages. Thx for a quick reply! |
Logger: homeassistant.components.sensor
Source: components/sensor/init.py:500
Integration: Sensor (documentation, issues)
First occurred: 18:57:56 (3 occurrences)
Last logged: 19:12:03
Entity sensor.p1ib_telegram_received (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using state class 'measurement' which is impossible considering device class ('timestamp') it is using; expected None; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22
Entity sensor.p1ib_reactive_energy_export_q3_q4 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using state class 'measurement' which is impossible considering device class ('energy') it is using; expected None or one of 'total_increasing', 'total'; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22
Entity sensor.p1ib_reactive_energy_import_q1_q2 (<class 'homeassistant.components.mqtt.sensor.MqttSensor'>) is using state class 'measurement' which is impossible considering device class ('energy') it is using; expected None or one of 'total_increasing', 'total'; Please update your configuration if your entity is manually configured, otherwise create a bug report at https://github.com/home-assistant/core/issues?q=is%3Aopen+is%3Aissue+label%3A%22integration%3A+mqtt%22