  1. The flanger stands totally still in the "I" preset, no matter the rate control. That one should have the noise LFO shape, and I remember we fixed a difference between the phaser and flanger at one point that made it not work in the flanger. In Shortcircuit the noise shape does work in the flanger though, so the issue must be in the conduit implementation not the sst-effects port.
  2. Across all of I II III on both effects, rate >20 sounds not great. Let's cap it?
  3. If it feels reasonable for you to go an extra mile here, I think best UX for these would be to have a preset macro instead of rate. It would control rate within the min-20hz range, but also change some other params along to keep the effect in the sweetspot across the rate range. Happy to set up a Surge patch with all six of these in it and a macro to each one as a reference. How about it?
@Andreya-Autumn Andreya-Autumn changed the title Mod FX Mod FX cleanup Oct 7, 2023
@Andreya-Autumn
Copy link
Contributor Author

...actually, on 1 above. I just noticed that when you first switch to flanger, it does seem to move for a second. Then stops somewhere, after which the rate control just makes a subtle timbral difference. I sanity checked against audio in to Surge and the preset is pretty subtle but in Surge you can definitely hear the noise when you dime the rate. Can't in Conduit.

@baconpaul
Copy link
Collaborator

On 3, that's relatively easy to do sure. I just need to know the base value for each macro-ed value and the upper range.

So somethin glike

"Patch 1: param 3 goes 12..15, param 6 goes 0.02 to -0.4 as macro goes 0 1"

I'l get the other two before we d that though.

baconpaul added a commit to baconpaul/conduit that referenced this issue Oct 7, 2023
1. ModFX CLeanup: Rate capped at 20hz
2. ModFX Cleanup: Random in place for Flanger 1 works. Addresses surge-synthesizer#44
3. Advanced Filter Gain Leveling. Closes surge-synthesizer#45
4. Start on a mod matrix messages
5. Restore the parallel filter routings.
baconpaul added a commit that referenced this issue Oct 7, 2023
1. ModFX CLeanup: Rate capped at 20hz
2. ModFX Cleanup: Random in place for Flanger 1 works. Addresses #44
3. Advanced Filter Gain Leveling. Closes #45
4. Start on a mod matrix messages
5. Restore the parallel filter routings.
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment
Labels
None yet
Projects
None yet
Development

No branches or pull requests

2 participants