[TTK 1.2 + Paraview 5.11.1] Infinite density in CSP computed for the tooth dataset #991
Comments
I confirm I can reproduce the issue on this dataset. |
I may have introduced a bug through #920 , I'll test whenever I have the chance. Thanks for reporting this |
Thanks a lot for this feedback @Lgt2x |
Hi, I suspect the bug might be centered around the four function calls of I did a quick check, as I see that the computation of triangle indices have been updated in the newer code (https://github.com/topology-tool-kit/ttk/pull/920/files - lines 270-288). FYI @Lgt2x - TTK 1.1.0 used the |
I took a quick look, you're right, |
Describe the bug
The density range is [0, infinity] in the CSP computed for the tooth dataset with TTK 1.2. It works perfectly fine with TTK 0.9.8. Here is the dataset file.
To Reproduce
The mentioned data file has two fields. Load it in Paraview with TTK 1.2. Apply the continuous scatterplot filter. Select the two fields and generate the CSP. Observe the density range in the information tab.
Expected behavior
The density range should be finite.
System (please complete the following information):
The text was updated successfully, but these errors were encountered: