Skip to content

Alias4D/Gas-Velocity-Flowrate-Calculator

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

15 Commits
 
 
 
 
 
 

Repository files navigation

Clean Gas Pipeline Safe Operation Velocity & Flowrate Calculator

Project Overview

This application calculates the safe operational velocity and flow rate for a clean gas pipeline, considering factors like compressibility factor (Z), gas temperature, pressure, gravity, and pipe diameter. It provides valuable insights for ensuring safe and efficient gas pipeline operation.

Features

  • Calculates both maximum velocity and safe operational velocity
  • Calculates volumetric flow rate in normal cubic meters per hour (Nm³/h)
  • User-friendly interface with clear input fields and labeled results

Refrence

  • Book : Gas pipeline hydraulics, E.Shashi Menon, 2005 by Taylor & Francis')
  • Standard : American Petroleum Institute Recommended Practice 14E (API RP 14E)

Developed by

Eng. Alias @ [email protected]