const {identify, battery, ota} = require('zigbee-herdsman-converters/lib/modernExtend'); | ||
const exposes = require('zigbee-herdsman-converters/lib/exposes'); | ||
const reporting = require('zigbee-herdsman-converters/lib/reporting'); | ||
const constants = require('zigbee-herdsman-converters/lib/constants'); | ||
const utils = require('zigbee-herdsman-converters/lib/utils'); | ||
const tz = require('zigbee-herdsman-converters/converters/toZigbee'); | ||
const {precisionRound, postfixWithEndpointName} = require('zigbee-herdsman-converters/lib/utils'); | ||
const e = exposes.presets; | ||
const ea = exposes.access; | ||
|
||
// We can only read and write after the device will post something. This particual device is sending messages one per minute. | ||
// Also metadata from main object does not seems to be working at the time of implementing this device, so all values are defined here again. | ||
const siemensTimeout = {timeout: 60000}; | ||
|
||
const siemensOperationModes = { | ||
0: '2-position, 1 K', | ||
1: '2-position, 0.3 K', | ||
2: 'TPI slow', | ||
3: 'TPI medium', | ||
4: 'TPI fast', | ||
}; | ||
|
||
|
||
const siemensFromZigbee = { | ||
cluster: 'hvacThermostat', | ||
type: ['attributeReport', 'readResponse'], | ||
convert: (model, msg, publish, options, meta) => { | ||
var result = {}; | ||
if (msg.data.hasOwnProperty('localTemperatureCalibration')) { | ||
result[postfixWithEndpointName('local_temperature_calibration', msg, model, meta)] = | ||
precisionRound(msg.data['localTemperatureCalibration'], 2) / 10; | ||
} | ||
if (msg.data.hasOwnProperty('localTemp')) { | ||
const value = precisionRound(msg.data['localTemp'], 2) / 100; | ||
if (value >= -273.15) { | ||
result[postfixWithEndpointName('local_temperature', msg, model, meta)] = value; | ||
} | ||
} | ||
if (msg.data.hasOwnProperty('occupiedHeatingSetpoint')) { | ||
const value = precisionRound(msg.data['occupiedHeatingSetpoint'], 2) / 100; | ||
// Stelpro will return -325.65 when set to off, value is not realistic anyway | ||
if (value >= -273.15) { | ||
result[postfixWithEndpointName('occupied_heating_setpoint', msg, model, meta)] = value; | ||
} | ||
} | ||
if (msg.data.hasOwnProperty('unoccupiedHeatingSetpoint')) { | ||
result[postfixWithEndpointName('unoccupied_heating_setpoint', msg, model, meta)] = | ||
precisionRound(msg.data['unoccupiedHeatingSetpoint'], 2) / 100; | ||
} | ||
if (msg.data.hasOwnProperty('systemMode')) { | ||
result[postfixWithEndpointName('system_mode', msg, model, meta)] = constants.thermostatSystemModes[msg.data['systemMode']]; | ||
} | ||
if (msg.data.hasOwnProperty('ctrlSeqeOfOper')) { | ||
result[postfixWithEndpointName('control_sequence_of_operation', msg, model, meta)] = | ||
siemensOperationModes[msg.data['ctrlSeqeOfOper']]; | ||
} | ||
|
||
return result; | ||
}, | ||
}; | ||
|
||
const tz_local_temperature = { | ||
key: ['local_temperature'], | ||
convertGet: async (entity, key, meta) => { | ||
await entity.read('hvacThermostat', ['localTemp'], siemensTimeout); | ||
}, | ||
}; | ||
|
||
const tz_control_sequence_of_operation = { | ||
key: ['control_sequence_of_operation'], | ||
convertSet: async (entity, key, value, meta) => { | ||
utils.assertEndpoint(entity); | ||
let val = utils.getKey(siemensOperationModes, value, undefined, Number); | ||
if (val === undefined) { | ||
val = utils.getKey(siemensOperationModes, value, value, Number); | ||
} | ||
await entity.write('hvacThermostat', {ctrlSeqeOfOper: val}, siemensTimeout); | ||
|
||
entity.saveClusterAttributeKeyValue('hvacThermostat', attributes); | ||
return {readAfterWriteTime: 250, state: {control_sequence_of_operation: value}}; | ||
}, | ||
convertGet: async (entity, key, meta) => { | ||
await entity.read('hvacThermostat', ['ctrlSeqeOfOper'], siemensTimeout); | ||
} | ||
}; | ||
|
||
const tz_system_mode = { | ||
key: ['system_mode'], | ||
convertSet: async (entity, key, value, meta) => { | ||
let systemMode = utils.getKey(constants.thermostatSystemModes, value, undefined, Number); | ||
if (systemMode === undefined) { | ||
systemMode = utils.getKey(legacy.thermostatSystemModes, value, value, Number); | ||
} | ||
await entity.write('hvacThermostat', {systemMode}, siemensTimeout); | ||
return {readAfterWriteTime: 250, state: {system_mode: value}}; | ||
}, | ||
convertGet: async (entity, key, meta) => { | ||
await entity.read('hvacThermostat', ['systemMode'], siemensTimeout); | ||
} | ||
}; | ||
|
||
const tz_local_temperature_calibration = { | ||
key: ['local_temperature_calibration'], | ||
convertSet: async (entity, key, value, meta) => { | ||
utils.assertNumber(value); | ||
await entity.write('hvacThermostat', {localTemperatureCalibration: Math.round(value * 10)}, siemensTimeout); | ||
return {state: {local_temperature_calibration: value}}; | ||
}, | ||
convertGet: async (entity, key, meta) => { | ||
await entity.read('hvacThermostat', ['localTemperatureCalibration'], siemensTimeout); | ||
} | ||
}; | ||
|
||
const tz_occupied_heating_setpoint = { | ||
key: ['occupied_heating_setpoint'], | ||
options: [exposes.options.thermostat_unit()], | ||
convertSet: async (entity, key, value, meta) => { | ||
utils.assertNumber(value, key); | ||
let result; | ||
if (meta.options.thermostat_unit === 'fahrenheit') { | ||
result = Math.round(utils.normalizeCelsiusVersionOfFahrenheit(value) * 100); | ||
} else { | ||
result = Number((Math.round(Number((value * 2).toFixed(1))) / 2).toFixed(1)) * 100; | ||
} | ||
const occupiedHeatingSetpoint = result; | ||
await entity.write('hvacThermostat', {occupiedHeatingSetpoint}, siemensTimeout); | ||
return {state: {occupied_heating_setpoint: value}}; | ||
}, | ||
convertGet: async (entity, key, meta) => { | ||
await entity.read('hvacThermostat', ['occupiedHeatingSetpoint'], siemensTimeout); | ||
} | ||
}; | ||
|
||
const tz_unoccupied_heating_setpoint = { | ||
key: ['unoccupied_heating_setpoint'], | ||
options: [exposes.options.thermostat_unit()], | ||
convertSet: async (entity, key, value, meta) => { | ||
utils.assertNumber(value, key); | ||
let result; | ||
if (meta.options.thermostat_unit === 'fahrenheit') { | ||
result = Math.round(utils.normalizeCelsiusVersionOfFahrenheit(value) * 100); | ||
} else { | ||
result = Number((Math.round(Number((value * 2).toFixed(1))) / 2).toFixed(1)) * 100; | ||
} | ||
const unoccupiedHeatingSetpoint = result; | ||
await entity.write('hvacThermostat', {unoccupiedHeatingSetpoint}); | ||
return {state: {unoccupied_heating_setpoint: value}, siemensTimeout}; | ||
}, | ||
convertGet: async (entity, key, meta) => { | ||
await entity.read('hvacThermostat', ['unoccupiedHeatingSetpoint'], siemensTimeout); | ||
} | ||
}; | ||
|
||
const definition = { | ||
zigbeeModel: ['RDZ100'], | ||
model: 'RDZ100', | ||
vendor: 'Siemens', | ||
description: 'Siemens RDZ100 Wireless Thermostat', | ||
fromZigbee: [ | ||
siemensFromZigbee, | ||
], | ||
toZigbee: [ | ||
tz_local_temperature, | ||
tz_control_sequence_of_operation, | ||
tz_system_mode, | ||
tz_local_temperature_calibration, | ||
tz_occupied_heating_setpoint, | ||
tz_unoccupied_heating_setpoint, | ||
], | ||
extend: [battery(), ota()], | ||
exposes: (device, options) => { | ||
const expose = [ | ||
e.climate() | ||
.withLocalTemperature() | ||
.withLocalTemperatureCalibration(-2.5, 2.5, 0.5) | ||
.withSetpoint('occupied_heating_setpoint', 5, 30, 0.5) | ||
.withSetpoint('unoccupied_heating_setpoint', 5, 30, 0.5) | ||
.withSystemMode(['off', 'heat'])]; | ||
|
||
expose.push(e.enum('control_sequence_of_operation', ea.STATE_SET, Object.values(siemensOperationModes)).withDescription('Operation mode')); | ||
|
||
return expose; | ||
}, | ||
meta: {}, | ||
configure: async (device, coordinatorEndpoint) => { | ||
const endpoint = device.getEndpoint(1); | ||
await reporting.bind(endpoint, coordinatorEndpoint, ['genPowerCfg', 'hvacThermostat']); | ||
await reporting.thermostatTemperature(endpoint); | ||
await reporting.thermostatOccupiedHeatingSetpoint(endpoint); | ||
await reporting.thermostatUnoccupiedHeatingSetpoint(endpoint); | ||
}, | ||
}; | ||
|
||
module.exports = definition; |