Code changes from #753, energy impact only.
Browse files Browse the repository at this point in the history
  • Loading branch information
shorowit committed May 14, 2021
1 parent f6f88ca commit a2c4fb5
Show file tree
Hide file tree
Showing 3 changed files with 58 additions and 35 deletions.
1 change: 1 addition & 0 deletions Changelog.md
Original file line number Diff line number Diff line change
Expand Up @@ -8,6 +8,7 @@ __New Features__
- Adds an `--ep-input-format` argument to run_simulation.rb to choose epJSON as the EnergyPlus input file format instead of IDF.
- Allows `HeatingSeason` & `CoolingSeason` to be specified for defining heating and cooling equipment availability.
- Removes error-check for number of bedrooms based on conditioned floor area, per RESNET guidance.
- Revises shared mechanical ventilation preconditioning control logic to operate less often.

__Bugfixes__
- Improves ground reflectance when there is shading of windows/skylights.
Expand Down
16 changes: 8 additions & 8 deletions HPXMLtoOpenStudio/measure.xml
Original file line number Diff line number Diff line change
Expand Up @@ -4,8 +4,8 @@
<error>Unable to extract OpenStudio::Measure::OSMeasure object from /mnt/c/git/openstudio-hpxml/HPXMLtoOpenStudio/measure.rb. The script should contain a class that derives from OpenStudio::Measure::OSMeasure and should close with a line stating the class name followed by .new.registerWithApplication.</error>
<name>hpxm_lto_openstudio</name>
<uid>b1543b30-9465-45ff-ba04-1d1f85e763bc</uid>
<version_id>c929f134-7b14-43a4-a9ee-11bb8d27da1f</version_id>
<version_modified>20210513T171148Z</version_modified>
<version_id>9d668d73-be14-4a65-b206-764f86eca574</version_id>
<version_modified>20210514T182320Z</version_modified>
<xml_checksum>D8922A73</xml_checksum>
<class_name>HPXMLtoOpenStudio</class_name>
<display_name>HPXML to OpenStudio Translator</display_name>
Expand Down Expand Up @@ -407,12 +407,6 @@
<usage_type>test</usage_type>
<checksum>4C662AE0</checksum>
</file>
<file>
<filename>airflow.rb</filename>
<filetype>rb</filetype>
<usage_type>resource</usage_type>
<checksum>99EB6060</checksum>
</file>
<file>
<filename>geometry.rb</filename>
<filetype>rb</filetype>
Expand Down Expand Up @@ -586,5 +580,11 @@
<usage_type>resource</usage_type>
<checksum>4BBE084E</checksum>
</file>
<file>
<filename>airflow.rb</filename>
<filetype>rb</filetype>
<usage_type>resource</usage_type>
<checksum>E5C505B7</checksum>
</file>
</files>
</measure>
76 changes: 49 additions & 27 deletions HPXMLtoOpenStudio/resources/airflow.rb
Original file line number Diff line number Diff line change
Expand Up @@ -2,7 +2,7 @@

class Airflow
def self.apply(model, runner, weather, spaces, hpxml, cfa, nbeds,
ncfl_ag, duct_systems, nv_clg_ssn_sensor, hvac_map, eri_version,
ncfl_ag, duct_systems, clg_ssn_sensor, hvac_map, eri_version,
frac_windows_operable, apply_ashrae140_assumptions)

# Global variables
Expand Down Expand Up @@ -106,10 +106,10 @@ def self.apply(model, runner, weather, spaces, hpxml, cfa, nbeds,
vented_crawl = foundation
end

apply_natural_ventilation_and_whole_house_fan(model, weather, hpxml.site, vent_fans_whf, open_window_area, nv_clg_ssn_sensor)
apply_natural_ventilation_and_whole_house_fan(model, weather, hpxml.site, vent_fans_whf, open_window_area, clg_ssn_sensor)
apply_infiltration_and_ventilation_fans(model, weather, hpxml.site, vent_fans_mech, vent_fans_kitchen, vent_fans_bath, vented_dryers,
hpxml.building_construction.has_flue_or_chimney, hpxml.air_infiltration_measurements,
vented_attic, vented_crawl, hvac_map)
vented_attic, vented_crawl, hvac_map, clg_ssn_sensor)
end

def self.get_default_fraction_of_windows_operable()
Expand Down Expand Up @@ -1486,6 +1486,8 @@ def self.calculate_fan_loads(model, infil_program, vent_mech_erv_hrv_tot, hrv_er
# Calculate mass flow rate based on outdoor air density
# Address load with flow-weighted combined effectiveness
infil_program.addLine("Set Fan_MFR = #{q_var} * OASupRho")
infil_program.addLine('Set ZoneInEnth = OASupInEnth')
infil_program.addLine('Set ZoneInTemp = OASupInTemp')
if not vent_mech_erv_hrv_tot.empty?
# ERV/HRV EMS load model
# E+ ERV model is using standard density for MFR calculation, caused discrepancy with other system types.
Expand All @@ -1502,14 +1504,12 @@ def self.calculate_fan_loads(model, infil_program, vent_mech_erv_hrv_tot, hrv_er
infil_program.addLine('Set ERVTotalHeatTrans = Fan_MFR * (ERVSupOutEnth - OASupInEnth)')
infil_program.addLine('Set ERVLatHeatTrans = ERVTotalHeatTrans - ERVSensHeatTrans')
# ERV/HRV Load calculation
infil_program.addLine('Set FanTotalToLv = Fan_MFR * (ERVSupOutEnth - ZoneAirEnth)')
infil_program.addLine('Set FanSensToLv = Fan_MFR * ZoneCp * (ERVSupOutTemp - ZoneTemp)')
infil_program.addLine('Set FanLatToLv = FanTotalToLv - FanSensToLv')
else
infil_program.addLine('Set FanTotalToLv = Fan_MFR * (OASupInEnth - ZoneAirEnth)')
infil_program.addLine('Set FanSensToLv = Fan_MFR * ZoneCp * (OASupInTemp - ZoneTemp)')
infil_program.addLine('Set FanLatToLv = FanTotalToLv - FanSensToLv')
infil_program.addLine('Set ZoneInEnth = ERVSupOutEnth')
infil_program.addLine('Set ZoneInTemp = ERVSupOutTemp')
end
infil_program.addLine('Set FanTotalToLv = Fan_MFR * (ZoneInEnth - ZoneAirEnth)')
infil_program.addLine('Set FanSensToLv = Fan_MFR * ZoneCp * (ZoneInTemp - ZoneTemp)')
infil_program.addLine('Set FanLatToLv = FanTotalToLv - FanSensToLv')

# Actuator,
# If preconditioned, handle actuators later in calculate_precond_loads
Expand All @@ -1519,11 +1519,23 @@ def self.calculate_fan_loads(model, infil_program, vent_mech_erv_hrv_tot, hrv_er
end
end

def self.calculate_precond_loads(model, infil_program, vent_mech_preheat, vent_mech_precool, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, hvac_map)
def self.calculate_precond_loads(model, infil_program, vent_mech_preheat, vent_mech_precool, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, hvac_map, clg_ssn_sensor)
# Preconditioning
# Assume introducing no sensible loads to zone if preconditioned
if not vent_mech_preheat.empty?
htg_stp_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Thermostat Heating Setpoint Temperature')
htg_stp_sensor.setName("#{Constants.ObjectNameAirflow} htg stp s")
htg_stp_sensor.setKeyName(@living_zone.name.to_s)
infil_program.addLine("Set HtgStp = #{htg_stp_sensor.name}") # heating thermostat setpoint
end
if not vent_mech_precool.empty?
clg_stp_sensor = OpenStudio::Model::EnergyManagementSystemSensor.new(model, 'Zone Thermostat Cooling Setpoint Temperature')
clg_stp_sensor.setName("#{Constants.ObjectNameAirflow} clg stp s")
clg_stp_sensor.setKeyName(@living_zone.name.to_s)
infil_program.addLine("Set ClgStp = #{clg_stp_sensor.name}") # cooling thermostat setpoint
end
vent_mech_preheat.each_with_index do |f_preheat, i|
infil_program.addLine('If OASupInTemp < ZoneTemp')
infil_program.addLine("If (OASupInTemp < HtgStp) && (#{clg_ssn_sensor.name} < 1)")
htg_energy_actuator = create_other_equipment_object_and_actuator(model: model, name: "shared mech vent preheating energy #{i}", space: @living_space, frac_lat: 0.0, frac_lost: 1.0, hpxml_fuel_type: f_preheat.preheating_fuel, end_use: Constants.ObjectNameMechanicalVentilationPreconditioning)
hvac_map["#{f_preheat.id}_preheat"] = [htg_energy_actuator.actuatedComponent.get]
infil_program.addLine(" Set Qpreheat = #{UnitConversions.convert(f_preheat.average_oa_unit_flow_rate, 'cfm', 'm^3/s').round(4)}")
Expand All @@ -1534,16 +1546,21 @@ def self.calculate_precond_loads(model, infil_program, vent_mech_preheat, vent_m
end
calculate_fan_loads(model, infil_program, vent_mech_erv_hrv_tot, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, 'Qpreheat', true)

infil_program.addLine(" Set PreHeatingEnergy = (-FanSensToLv) * #{f_preheat.preheating_fraction_load_served}")
infil_program.addLine(" Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} + PreHeatingEnergy")
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} - FanLatToLv")
infil_program.addLine(" Set #{htg_energy_actuator.name} = PreHeatingEnergy / #{f_preheat.preheating_efficiency_cop}")
infil_program.addLine(' If ZoneInTemp < HtgStp')
infil_program.addLine(' Set FanSensToSpt = Fan_MFR * ZoneCp * (ZoneInTemp - HtgStp)')
infil_program.addLine(" Set PreHeatingWatt = (-FanSensToSpt) * #{f_preheat.preheating_fraction_load_served}")
infil_program.addLine(" Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} + PreHeatingWatt")
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} - FanLatToLv") # Fixme:Does this assumption still apply?
infil_program.addLine(' Else')
infil_program.addLine(' Set PreHeatingWatt = 0.0')
infil_program.addLine(' EndIf')
infil_program.addLine('Else')
infil_program.addLine(" Set #{htg_energy_actuator.name} = 0.0")
infil_program.addLine(' Set PreHeatingWatt = 0.0')
infil_program.addLine('EndIf')
infil_program.addLine("Set #{htg_energy_actuator.name} = PreHeatingWatt / #{f_preheat.preheating_efficiency_cop}")
end
vent_mech_precool.each_with_index do |f_precool, i|
infil_program.addLine('If OASupInTemp > ZoneTemp')
infil_program.addLine("If (OASupInTemp > ClgStp) && (#{clg_ssn_sensor.name} > 0)")
clg_energy_actuator = create_other_equipment_object_and_actuator(model: model, name: "shared mech vent precooling energy #{i}", space: @living_space, frac_lat: 0.0, frac_lost: 1.0, hpxml_fuel_type: f_precool.precooling_fuel, end_use: Constants.ObjectNameMechanicalVentilationPreconditioning)
hvac_map["#{f_precool.id}_precool"] = [clg_energy_actuator.actuatedComponent.get]
infil_program.addLine(" Set Qprecool = #{UnitConversions.convert(f_precool.average_oa_unit_flow_rate, 'cfm', 'm^3/s').round(4)}")
Expand All @@ -1554,18 +1571,23 @@ def self.calculate_precond_loads(model, infil_program, vent_mech_preheat, vent_m
end
calculate_fan_loads(model, infil_program, vent_mech_erv_hrv_tot, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, 'Qprecool', true)

infil_program.addLine(" Set PreCoolingEnergy = FanSensToLv * #{f_precool.precooling_fraction_load_served}")
infil_program.addLine(" Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} - PreCoolingEnergy")
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} - FanLatToLv")
infil_program.addLine(" Set #{clg_energy_actuator.name} = PreCoolingEnergy / #{f_precool.precooling_efficiency_cop}")
infil_program.addLine(' If ZoneInTemp > ClgStp')
infil_program.addLine(' Set FanSensToSpt = Fan_MFR * ZoneCp * (ZoneInTemp - ClgStp)')
infil_program.addLine(" Set PreCoolingWatt = FanSensToSpt * #{f_precool.precooling_fraction_load_served}")
infil_program.addLine(" Set #{fan_sens_load_actuator.name} = #{fan_sens_load_actuator.name} - PreCoolingWatt")
infil_program.addLine(" Set #{fan_lat_load_actuator.name} = #{fan_lat_load_actuator.name} - FanLatToLv") # Fixme:Does this assumption still apply?
infil_program.addLine(' Else')
infil_program.addLine(' Set PreCoolingWatt = 0.0')
infil_program.addLine(' EndIf')
infil_program.addLine('Else')
infil_program.addLine(" Set #{clg_energy_actuator.name} = 0.0")
infil_program.addLine(' Set PreCoolingWatt = 0.0')
infil_program.addLine('EndIf')
infil_program.addLine("Set #{clg_energy_actuator.name} = PreCoolingWatt / #{f_precool.precooling_efficiency_cop}")
end
end

def self.apply_infiltration_and_mechanical_ventilation(model, site, vent_fans_mech, living_ach50, living_const_ach, weather, vent_fans_kitchen, vent_fans_bath, vented_dryers,
range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map, has_flue_chimney, hvac_map)
range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map, has_flue_chimney, hvac_map, clg_ssn_sensor)
# Categorize fans into different types
vent_mech_preheat = vent_fans_mech.select { |vent_mech| (not vent_mech.preheating_efficiency_cop.nil?) }
vent_mech_precool = vent_fans_mech.select { |vent_mech| (not vent_mech.precooling_efficiency_cop.nil?) }
Expand Down Expand Up @@ -1640,7 +1662,7 @@ def self.apply_infiltration_and_mechanical_ventilation(model, site, vent_fans_me
calculate_fan_loads(model, infil_program, vent_mech_erv_hrv_tot, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, 'Qload')

# Address preconditioning
calculate_precond_loads(model, infil_program, vent_mech_preheat, vent_mech_precool, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, hvac_map)
calculate_precond_loads(model, infil_program, vent_mech_preheat, vent_mech_precool, hrv_erv_effectiveness_map, fan_sens_load_actuator, fan_lat_load_actuator, hvac_map, clg_ssn_sensor)

program_calling_manager = OpenStudio::Model::EnergyManagementSystemProgramCallingManager.new(model)
program_calling_manager.setName("#{infil_program.name} calling manager")
Expand All @@ -1649,7 +1671,7 @@ def self.apply_infiltration_and_mechanical_ventilation(model, site, vent_fans_me
end

def self.apply_infiltration_and_ventilation_fans(model, weather, site, vent_fans_mech, vent_fans_kitchen, vent_fans_bath, vented_dryers,
has_flue_chimney, air_infils, vented_attic, vented_crawl, hvac_map)
has_flue_chimney, air_infils, vented_attic, vented_crawl, hvac_map, clg_ssn_sensor)
# Get living space infiltration
living_ach50 = nil
living_const_ach = nil
Expand Down Expand Up @@ -1687,7 +1709,7 @@ def self.apply_infiltration_and_ventilation_fans(model, weather, site, vent_fans

# Get mechanical ventilation
apply_infiltration_and_mechanical_ventilation(model, site, vent_fans_mech, living_ach50, living_const_ach, weather, vent_fans_kitchen, vent_fans_bath, vented_dryers,
range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map, has_flue_chimney, hvac_map)
range_sch_sensors_map, bath_sch_sensors_map, dryer_exhaust_sch_sensors_map, has_flue_chimney, hvac_map, clg_ssn_sensor)
end

def self.apply_infiltration_to_living(site, living_ach50, living_const_ach, infil_program, weather, has_flue_chimney)
Expand Down

0 comments on commit a2c4fb5