Fix #5343 - Design Range Temperature for OS:CoolingTower:SingleSpeed …
Browse files Browse the repository at this point in the history
…is not being converted into EnergyPlus
  • Loading branch information
jmarrec committed Jan 14, 2025
1 parent fd036ed commit d438c3b
Showing 1 changed file with 1 addition and 1 deletion.
Original file line number Diff line number Diff line change
Expand Up @@ -252,7 +252,7 @@ namespace energyplus {

if (modelObject.isDesignRangeTemperatureAutosized()) {
idfObject.setString(openstudio::CoolingTower_SingleSpeedFields::DesignRangeTemperature, "Autosize");
} else if ((d = modelObject.designApproachTemperature())) {
} else if ((d = modelObject.designRangeTemperature())) {
idfObject.setDouble(openstudio::CoolingTower_SingleSpeedFields::DesignRangeTemperature, d.get());
}