v2024.6.1
v2024.6.2-alpha1
What's changed
- Ensure keep_alive refreshes the devices states. Closes #201
Full Changelog: 2024.6.1...keep_alive_fix
v2024.6.0
Breaking Change
The integral computation now takes into account the external temperature compensation to allow negative integral values to avoid being stuck at 100%. The integral part is also cleared when external temperature is used and set point is changed. You may need to adjust the ki
gain to adjust the reactivity after set point steps.
What's Changed
- Allow controlling multiple heater/cooler entities with one single thermostat. Closes #217 #213 #192
- Take external temperature compensation into account for integral clamping. Closes #150 #151 #208 #222
- Add control output range setting parameters
output_min
andoutput_max
. Closes #79 #192 #222 - Add control output precision parameter
output_precision
to adjust number of decimals depending on target device. Closes #222 - Add control output clamping
out_clamp_low
andout_clamp_high
to limit output power. - Add more detailed examples in ReadMe
- Add "Buy Me a Coffee" badge to ReadMe
Full Changelog: 2024.2.1...2024.6.0
Frost Protect test alpha
Full Changelog: 2024.4.0-beta1...frost_protect_test
v2024.4.0-beta1
What's Changed
- Allow controlling multiple heater/cooler entities with one single thermostat. Closes #217 #213 #192
- Add control output range setting parameters
output_min
andoutput_max
. Closes #79 #192 - Add control output clamping
out_clamp_low
andout_clamp_high
to limit output power. - Add more detailed examples in ReadMe
- Add "Buy Me a Coffee" badge to ReadMe
Full Changelog: 2024.2.1...2024.4.0-beta1
v2024.3.0-beta1
What's Changed
- Add control output range setting parameters
output_min
andoutput_max
- Add control output clamping
out_clamp_low
andout_clamp_high
Full Changelog: 2024.2.1...2024.3.0-beta1
2024.2.1
v2024.2.0
What's Changed
- Do not throw an error if heater/cooler entity is not yet available on startup by @Chupaka in #172
- Autotune doc fix by @ybizeul in #199
- Add TURN_ON and TURN_OFF features. Closes #206
Breaking change
This release requires Home Assistant starting from 2024.2.0
New Contributors
Full Changelog: 2023.10.0...2024.2.0
v2023.10.0
v2023.9.0
What's new:
- Add
force_off_state
parameter to select if thermostat should force heater OFF when disabled. #136 #158 - Change
ac_mode
parameter behavior:- Setting
ac_mode: true
in the YAML configuration will enable both HEAT and COOL HVAC modes, allowing toggling it directly in the thermostat's card or by using coreclimate.set_hvac_mode
service. #86 - If the system uses two separated entities to control heating and cooling, use the new
cooler
parameter in YAML configuration to declare the cooler entity ID.
- Setting
- Allow using input_number entities for heater or cooler. #160 #123 #25
Full Changelog: 2023.6.0...2023.9.0