FHIR Bridge application uses HAPI FHIR validation API to perform the validation of FHIR resources.
Using the default configuration, the terminology validation is disabled and there is no control over the vocabulary used in the submitted resources.
However the application supports 3 different modes that might be activated using the following configuration property: fhir-bridge.fhir.validation.terminology.mode
. The value of the property should be one of the enum values defines in the TerminologyValidationMode
enumartion.
No terminology checks executed on the submitted FHIR resources.
fhir-bridge:
fhir:
validation:
terminology:
mode: none
This mode enables the InMemoryTerminologyServerValidationSupport
and CommonCodeSystemsTerminologyService
provided by HAPI FHIR in order to perform the validation.
INFO: This mode allows to validate most of the terminologies defined as part of the FHIR specification. Other CodeSystems and ValueSets are ignored.
fhir-bridge:
fhir:
validation:
terminology:
mode: internal
This mode validates the content of the submitted resources using a remote FHIR-based terminology server.
This last version of the FHIR-Bridge is now using the RemoteTerminologyServiceValidationSupport
when the remote terminology validation is enabled.
WARNING: When this mode is enabled, the FHIR-Brdige validates all the terminology content using the remote server. Consequently, please make sure that the instance of the remote terminology server contains the mandatory CodeSystems and ValueSets.
fhir-bridge:
fhir:
validation:
terminology:
mode: remote
server-base-url: https://fhir-terminology-server.ehrbase.org/fhir
WARNING: Do not forget to configure the remote terminology server URL using the property:
fhir-bridge.fhir.validation.terminology.server-base-url
This mode combines the features of the TerminologyValidationMode.INTERNAL
and the TerminologyValidationMode.REMOTE
, as described above.
fhir-bridge:
fhir:
validation:
terminology:
mode: mixed
server-base-url: https://fhir-terminology-server.ehrbase.org/fhir
WARNING: Do not forget to configure the remote terminology server URL using the property:
fhir-bridge.fhir.validation.terminology.server-base-url
If the remote terminology server requires to establish a Two-Way SSL (Mutual Authentication) connection, the FHIR Bridge can setup the SSL context using few additional configuration properties:
fhir-bridge:
fhir:
validation:
terminology:
mode: mixed
server-base-url: https://two-way-ssl.terminology-server.ehrbase.org/fhir
http-client:
ssl:
enabled: true
key-password: # Password used to access the key in the key store
key-store: # Path to the key store that holds the SSL certificate
key-store-password: # Password used to access the key store
key-store-type: # Type of the key store
trust-store: # Trust store that holds SSL certificates
trust-store-password: # Password used to access the trust store
trust-store-type: # Type of the trust store