Notifications
You must be signed in to change notification settings - Fork 392
EM4233 dump reference
Fabian Peters edited this page May 9, 2019
·
1 revision
You can find an example dump in Dumps/EM4233_example.dmp
and a template for 010 Editor in Software/EM4233_010Editor_Template.bt
Where not specified (regarding lock statuses):
-
0b
means unlocked -
1b
means locked
Memory address (in hex) | Lenght (in bytes) | Content |
---|---|---|
0x00 |
0xFF |
Tag dump data |
0xD0 |
0x08 |
UID (0xE0 0x16 0x24 ... ) |
0xD8 |
0x01 |
AFI |
0xD9 |
0x01 |
DSFID |
0xDC |
0x04 |
Info bits (see Table 2) |
0xE0 |
0x34 |
Lock status byte (see Table 3) |
0x0114 |
0x04 |
level 0 security password |
0x0118 |
0x0C |
level 1 security key |
MSB | LSB | ||||||||
---|---|---|---|---|---|---|---|---|---|
Byte 0 | RFU | RFU | RFU | RFU | RFU | RFU | RFU | DSFID lock status | AFI lock status |
Byte 1 | RFU | RFU | RFU | RFU | RFU | RFU | RFU | RFU | RFU |
Byte 2 | RFU | RFU | RFU | RFU | RFU | RFU | RFU | RFU | RFU |
Byte 3 | RFU | RFU | RFU | RFU | RFU | RFU | RFU | RFU | RFU |
Examples
01 00 00 00
AFI locked - DSFID unlocked
03 00 00 00
AFI locked - DSFID locked
MSB | LSB | |||||||
---|---|---|---|---|---|---|---|---|
RFU | RFU | RFU | RFU | RFU | Write protection | Read protection | Factory lock | User lock |
Examples
0x01
User locked
0x0C
Write protected - Read protected
- MSB: Most Significant Bit
- LSB: Least Significant Bit
-
RFU: Reserved for Future Usage - Shall be
0b
- Write/Read protected: According to EM datasheet