## BGEtech
### DS100
<DeviceFeatures features="" />
<Tabs>
<TabItem value="grid" label="Netz" default>
<DeviceConfig code={`meters:
- name: my_grid
type: template
template: bge_tech_ds100
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="pv" label="PV">
<DeviceConfig code={`meters:
- name: my_pv
type: template
template: bge_tech_ds100
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="charge" label="Wallbox">
<DeviceConfig code={`meters:
- name: my_charger
type: template
template: bge_tech_ds100
usage: charge
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="aux" label="AUX">
<DeviceConfig code={`meters:
- name: my_aux
type: template
template: bge_tech_ds100
usage: aux
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
</Tabs>
<!-- AUTO-GENERATED FROM TEMPLATE - PLEASE EDIT HERE https://github.com/evcc-io/evcc/tree/master/templates/definition/meter -->
### WS100
<DeviceFeatures features="" />
<Tabs>
<TabItem value="grid" label="Netz" default>
<DeviceConfig code={`meters:
- name: my_grid
type: template
template: bge_tech_ws100
usage: grid
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="pv" label="PV">
<DeviceConfig code={`meters:
- name: my_pv
type: template
template: bge_tech_ws100
usage: pv
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="charge" label="Wallbox">
<DeviceConfig code={`meters:
- name: my_charger
type: template
template: bge_tech_ws100
usage: charge
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="aux" label="AUX">
<DeviceConfig code={`meters:
- name: my_aux
type: template
template: bge_tech_ws100
usage: aux
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 1200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
</Tabs>
Expand Down Expand Up @@ -3686,6 +3946,77 @@ Die aktive Ladesteuerung nutzt den ersten Zeitslot für den "Battery first" modu
## Huawei
### EMMA
<DeviceFeatures features="" />
<Tabs>
<TabItem value="grid" label="Netz" default>
<DeviceConfig code={`meters:
- name: my_grid
type: template
template: huawei-emma
usage: grid
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="pv" label="PV">
<DeviceConfig code={`meters:
- name: my_pv
type: template
template: huawei-emma
usage: pv
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} />
</TabItem>
<TabItem value="battery" label="Batterie">
<DeviceConfig code={`meters:
- name: my_battery
type: template
template: huawei-emma
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port`} advanced={`meters:
- name: my_battery
type: template
template: huawei-emma
usage: battery
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
capacity: 50 # Akkukapazität in kWh (optional)`} />
</TabItem>
</Tabs>
<!-- AUTO-GENERATED FROM TEMPLATE - PLEASE EDIT HERE https://github.com/evcc-io/evcc/tree/master/templates/definition/meter -->
### SmartLogger
<DeviceFeatures features="battery-control" />
Expand Down Expand Up @@ -6750,7 +7081,7 @@ In der Weboberfläche des SMA Data Manager muss im Bereich "Externe Kommunikatio
<DeviceFeatures features="battery-control" />
Die Verbindung über einen LSE-3 Logger Stick mittels ModBus TCP ist möglich, jedoch kann Battery Control darüber nicht genutzt werden. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus TCP über Port 8899 ist die einfachste Anbindung. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
<Tabs>
<TabItem value="grid" label="Netz" default>
Expand Down Expand Up @@ -6875,7 +7206,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels ModBus TCP ist möglich, j
<DeviceFeatures features="battery-control" />
Die Verbindung über einen LSE-3 Logger Stick mittels ModBus TCP ist möglich, jedoch kann Battery Control darüber nicht genutzt werden. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus TCP über Port 8899 ist die einfachste Anbindung. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
<Tabs>
<TabItem value="grid" label="Netz" default>
Expand Down Expand Up @@ -7123,7 +7454,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels ModBus TCP ist möglich, j
<DeviceFeatures features="battery-control" />
Die Verbindung über einen LSE-3 Logger Stick mittels ModBus TCP ist möglich, jedoch kann Battery Control darüber nicht genutzt werden. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus TCP über Port 8899 ist die einfachste Anbindung. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
<Tabs>
<TabItem value="grid" label="Netz" default>
Expand Down Expand Up @@ -7248,7 +7579,7 @@ Die Verbindung über einen LSE-3 Logger Stick mittels ModBus TCP ist möglich, j
<DeviceFeatures features="battery-control" />
Die Verbindung über einen LSE-3 Logger Stick mittels ModBus TCP ist möglich, jedoch kann Battery Control darüber nicht genutzt werden. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
Die Verbindung über einen LSE-3 Logger Stick mittels LAN Anschluss und ModBus TCP über Port 8899 ist die einfachste Anbindung. Der LSW-3 WLAN Stick wird nicht unterstützt. Bei seriellem Anschluss via RS485 am COM Port ist eine wechselrichterseitige Terminierung notwendig.
<Tabs>
<TabItem value="grid" label="Netz" default>
Expand Down