Skip to content

Commit

Permalink
Templates update evcc-io/evcc@32dc838
Browse files Browse the repository at this point in the history
  • Loading branch information
andig committed Dec 30, 2023
1 parent fcb2350 commit c39926c
Show file tree
Hide file tree
Showing 8 changed files with 408 additions and 0 deletions.
51 changes: 51 additions & 0 deletions templates/de/charger/delta_0.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
product:
brand: Delta
description: AC Max Basic
capabilities: ["mA", "rfid"]
requirements: ["sponsorship"]
render:
- default: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
connector: 1 # optional
51 changes: 51 additions & 0 deletions templates/de/charger/delta_1.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
product:
brand: Delta
description: AC MAX Smart
capabilities: ["mA", "rfid"]
requirements: ["sponsorship"]
render:
- default: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
connector: 1 # optional
51 changes: 51 additions & 0 deletions templates/de/charger/delta_2.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
product:
brand: Delta
description: SLIM Charger
capabilities: ["mA", "rfid"]
requirements: ["sponsorship"]
render:
- default: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
connector: 1 # optional
51 changes: 51 additions & 0 deletions templates/de/charger/delta_3.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
product:
brand: Delta
description: Ultra Fast Charger
capabilities: ["mA", "rfid"]
requirements: ["sponsorship"]
render:
- default: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
connector: 1 # optional
51 changes: 51 additions & 0 deletions templates/en/charger/delta_0.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
product:
brand: Delta
description: AC Max Basic
capabilities: ["mA", "rfid"]
requirements: ["sponsorship"]
render:
- default: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
connector: 1 # optional
51 changes: 51 additions & 0 deletions templates/en/charger/delta_1.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
product:
brand: Delta
description: AC MAX Smart
capabilities: ["mA", "rfid"]
requirements: ["sponsorship"]
render:
- default: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
connector: 1 # optional
51 changes: 51 additions & 0 deletions templates/en/charger/delta_2.yaml
Original file line number Diff line number Diff line change
@@ -0,0 +1,51 @@
product:
brand: Delta
description: SLIM Charger
capabilities: ["mA", "rfid"]
requirements: ["sponsorship"]
render:
- default: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
advanced: |
type: template
template: delta
# RS485 via adapter (Modbus RTU)
modbus: rs485serial
id: 1
device: /dev/ttyUSB0 # USB-RS485 Adapter Adresse
baudrate: 115200 # Prüfe die Geräteeinstellungen, typische Werte sind 9600, 19200, 38400, 57600, 115200
comset: "8N1" # Kommunikationsparameter für den Adapter
# RS485 via TCP/IP (Modbus RTU)
modbus: rs485tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
# Modbus TCP
modbus: tcpip
id: 1
host: 192.0.2.2 # Hostname
port: 502 # Port
connector: 1 # optional
Loading

0 comments on commit c39926c

Please sign in to comment.