Notifications
You must be signed in to change notification settings - Fork 0
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
3 changed files
with
211 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,185 @@ | ||
-- | ||
-- Juniper Enterprise Specific MIB: Alarm MIB | ||
-- | ||
-- Copyright (c) 2001-2003, Juniper Networks, Inc. | ||
-- All rights reserved. | ||
-- | ||
-- The contents of this document are subject to change without notice. | ||
-- | ||
|
||
JUNIPER-ALARM-MIB DEFINITIONS ::= BEGIN | ||
|
||
IMPORTS | ||
MODULE-IDENTITY, OBJECT-TYPE, Gauge32 | ||
FROM SNMPv2-SMI | ||
TimeStamp | ||
FROM SNMPv2-TC | ||
jnxMibs | ||
FROM JUNIPER-SMI; | ||
|
||
jnxAlarms MODULE-IDENTITY | ||
LAST-UPDATED "200307182153Z" -- Fri Jul 18 21:53:46 2003 UTC | ||
ORGANIZATION "Juniper Networks, Inc." | ||
CONTACT-INFO | ||
" Juniper Technical Assistance Center | ||
Juniper Networks, Inc. | ||
1133 Innovation Way | ||
Sunnyvale, CA 94089 | ||
E-mail: [email protected]" | ||
|
||
DESCRIPTION | ||
"This is Juniper Networks' implementation of enterprise | ||
specific MIB for alarms from the router chassis box." | ||
::= { jnxMibs 4 } | ||
|
||
|
||
|
||
|
||
-- ::= { jnxAlarms 1 } This OID is obsolete. | ||
|
||
|
||
-- | ||
-- Craft Alarms | ||
-- | ||
|
||
jnxCraftAlarms OBJECT IDENTIFIER ::= { jnxAlarms 2 } | ||
|
||
|
||
jnxAlarmRelayMode OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
other(1), -- other or unknown | ||
passOn(2), -- alarms being passed on | ||
cutOff(3) -- alarms being cut off | ||
} | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The alarm relay mode of the craft interface | ||
panel for both yellow and red alarms. | ||
|
||
Both yellow and red alarms could be cut off | ||
by a front panel Alarm Cutoff / Lamp Test | ||
(ACO/LT) button. | ||
|
||
In the pass-on mode, the alarm relay will be | ||
activated to pass on the yellow or red alarms. | ||
In the cut-off mode, both yellow and red alarms | ||
will be cut off from the alarm relays which are | ||
normally connected to audible sirens or visual | ||
flashing devices." | ||
|
||
|
||
::= { jnxCraftAlarms 1 } | ||
|
||
|
||
jnxYellowAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 2 } | ||
|
||
jnxYellowAlarmState OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
other(1), -- alarm state is unknown | ||
off(2), -- alarm is off | ||
on(3) -- alarm is on | ||
} | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The yellow alarm state on the craft interface | ||
panel. | ||
|
||
The yellow alarm is on when there is some | ||
system warning such as maintenance alert or | ||
significant temperature increase. | ||
|
||
This yellow alarm state could be turned off | ||
by the ACO/LT (Alarm Cut Off / Lamp Test) button | ||
on the front panel module." | ||
|
||
|
||
::= { jnxYellowAlarms 1 } | ||
|
||
jnxYellowAlarmCount OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The number of currently active and non-silent | ||
yellow alarms. | ||
|
||
This object is independent of the ACO/LT (Alarm | ||
Cut Off / Lamp Test) button." | ||
|
||
|
||
::= { jnxYellowAlarms 2 } | ||
|
||
|
||
jnxYellowAlarmLastChange OBJECT-TYPE | ||
SYNTAX TimeStamp | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The value of sysUpTime when the yellow alarm | ||
last changed - either from off to on or vice | ||
versa. Zero if unknown or never changed since | ||
the agent was up." | ||
|
||
|
||
::= { jnxYellowAlarms 3 } | ||
|
||
|
||
jnxRedAlarms OBJECT IDENTIFIER ::= { jnxCraftAlarms 3 } | ||
|
||
jnxRedAlarmState OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
other(1), -- alarm state is unknown | ||
off(2), -- alarm is off | ||
on(3) -- alarm is on | ||
} | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The red alarm indication on the craft interface | ||
panel. | ||
|
||
The red alarm is on when there is some system | ||
failure or power supply failure or the system | ||
is experiencing a hardware malfunction or some | ||
threshold is being exceeded. | ||
|
||
This red alarm state could be turned off by the | ||
ACO/LT (Alarm Cut Off / Lamp Test) button on the | ||
front panel module." | ||
|
||
|
||
::= { jnxRedAlarms 1 } | ||
|
||
|
||
jnxRedAlarmCount OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The number of currently active and non-silent | ||
red alarms. | ||
|
||
This object is independent of the ACO/LT (Alarm | ||
Cut Off / Lamp Test) button." | ||
|
||
|
||
::= { jnxRedAlarms 2 } | ||
|
||
|
||
jnxRedAlarmLastChange OBJECT-TYPE | ||
SYNTAX TimeStamp | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The value of sysUpTime when the red alarm | ||
last changed - either from off to on or vice | ||
versa. Zero if unknown or never changed since | ||
the agent was up." | ||
|
||
|
||
::= { jnxRedAlarms 3 } | ||
|
||
|
||
END |