Skip to content

leowinterde/BMS

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

28 Commits
 
 
 
 
 
 
 
 
 
 

Repository files navigation

China Battery BMS

Fork from https://github.com/mytest4u/BMS

Warning Use at your own risk, especially the firmware!

Facts:

BMS: DR01 or DR-JC03
Capacity: from 60Ah, up to 300Ah
Where to buy: all over Aliexpress, like "PAPOOL LiFePO4"

battery image

Connect to Victron Controller

First of when only DIP 6 is facing upwards, it's recognized as a "Pylontech battery" and the charge controller will not see any battery details like cell voltage, temps - so avoid using this mode.

Cerbo GX

Buy a cable from Victron or build it yourself: Cerbo GX: VE.Can to CAN-bus BMS cables manual. DIP 5 & DIP 6 up, conenct the special CAT cabel and enjoy the battery details.

Venus OS

Victron Venus OS provides the Battery Can Bus drivers but not the Hardware port. So just get a Waveshare RS485 CAN Pi HAT and connect GND, CAN-L (Low) to Pin 5 and CAN-H (High) to Pin 4.

There are certainly other options for non-Raspberry Pis Venus OS setups. So we do not need BMS support in dbus-serialbattery / issue support BMS DR-JC03.

Battery Stack Setup

  1. Connect the master pack with DIP 5 and 6 facing upwards, as indicated in the Victron connection instructions.
  2. The pack will be recognized as an "LFP battery" and you can view the voltage of the highest and lowest cell under the "Details" section.
  3. You can also see the number of packs online and if there's a pack preventing charging/discharging.

DR Software - Reading data/Firmware Upgrade Tool

  • Set address to 0
  • Password: 666666

How to update the firmware

  1. Connect the PC and battery using a cable, ensuring that DIP 1 is turned ON for PC connection.
  2. Make sure to install the necessary RS485 drivers for the connection to be established.
  3. Open the "DR-Application.exe" application and keep the window open.
  4. Open the "index.html" file located in the "dist" folder using a web browser.
  5. On the "Help" tab, change the language to English and enter the password 666666 if prompted.
  6. In the "Settings" tab, select the "Update" option, choose the bin file, and initiate the flashing process (you will know it's working if the green LED on the battery is flashing).

or take a look at Battery Upgrade Process.pdf


Firmware Files (gladly PR new ones)

DR01_16S100JC03_V2 0 0_T1_V - The V in the file stands for Victron

sha256 96a0056fe39f611eaca99b5e9c753bf73fabed1b06a1ef61a0f659c9b8b9498d

Product info 2.2
Hardware model T1_G
Product model JC03
Project code 16S100
Software version 2.01
Boot version 1.1

48V100AH - also detects the 120AH battery version

sha256 377a63935bc880420edbaf2faf335d6700fa1701b2f09f6ecd427720856bd2f9

Product info 2.2
Hardware model T1_V
Product model DR01
Project code 16S100JC03
Software version 2.0.0
Boot version 1.1

Untested

Info Please commit if tested.

  • BOOT_UP_KF01JC00014V2.4.bin sha256 649e54ece972b0706a18d90687674c584f596b8bad1b803fd2c6db2e2d4823b0

  • DR-HUANY04_16S100A_V1.0.3_T1_V.bin sha256 2ab40293fe1cc930837c42cb04495545e93a98633c7a6b8c0b7f2b2cdf014e05

  • DR01_16S100JC03_V2.0.0_T1_G.bin sha256 0e0ba2e8e551c005d1cd58bd3407c254c03bf80fc6b5fd6d6c3cc39c622d339a

  • DR01_16S100JC03_V2.0.0_T2_V_R.bin sha256 1045c8b26c0770612da1726135c0606075eeb9d43ef77526d3e939386367df5d

  • DR_SAIENSI01_16S100A_V1.0.3_T1_G.bin sha256 9bf6b00d5d507c91dd6141682beae771fb1754d74db53631df96c3aeb25205e2