Added Service to force charging OFF (for 5 minutes)
Force stop charging when PV power is too low
Unfortunately, it is possible that the go-eCharger does not finish charging in ECO mode using the PV power (in a timely manner). To ensure that charging stops when there is no longer enough PV power, you can add the following automation:
You need to adjust the entity ids: switch.goe_012345_fup
, sensor.goe_012345_nrg_11
and sensor.goe_012345_pvopt_averagepgrid
(replace the 012345
with your serial number) and your preferred threshold when this automation should be executed (the above: -200
for the pvopt_averagepgrid
means, that as soon as the average power you export to the grid is less than 200 watt the automation will be triggered).
alias: go-e FORCE STOP of PV surplus charging
description: >-
Simple automation to ensure that the go-eCharger will stop charging when average PV will drop below given threshold
trigger:
- platform: time_pattern
seconds: /5
condition:
- condition: state
entity_id: switch.goe_012345_fup
state: "on"
- condition: numeric_state
entity_id: sensor.goe_012345_nrg_11
above: 200
- condition: numeric_state
entity_id: sensor.goe_012345_pvopt_averagepgrid
above: -200
action:
- service: goecharger_api2.stop_charging
mode: single