139 changes: 66 additions & 73 deletions db/core/ecmcMotorRecord.template
Original file line number Diff line number Diff line change
@@ -1,5 +1,4 @@
record(motor,"$(PREFIX)$(MOTOR_NAME)")
{
record(motor, "$(PREFIX)$(MOTOR_NAME)") {
field(DESC, "$(DESC)")
field(DTYP, "asynMotor")
field(DIR, "$(DIR=0)")
Expand All @@ -24,7 +23,7 @@ record(motor,"$(PREFIX)$(MOTOR_NAME)")
field(RTRY, "$(RTRY=1)")
field(RMOD, "$(RMOD=3)")
field(DLY, "$(DLY=0)")
field(OFF, "$(OFF=0)")
field(OFF, "$(OFF=0)")
field(FOFF, "$(FOFF=0)")
field(NTM, "$(NTM=1)")
field(TWV, "$(TWV=1)")
Expand All @@ -35,17 +34,20 @@ record(motor,"$(PREFIX)$(MOTOR_NAME)")
field(SREV, "$(SREV=1)")
field(UREV, "$(UREV=1.0)")
field(VMAX, "$(VMAX=0)")

$(ECMC_BLOCK_ARCHIVER)info(aa_policy, "$(ECMC_ARCHIVER_POLICY)")
$(ECMC_BLOCK_ARCHIVER)info(archiver, "$(ECMC_ARCHIVER_CLUSTER)")
}

# The message text
record(stringin,"$(PREFIX)$(MOTOR_NAME)-MsgTxt") {
record(stringin, "$(PREFIX)$(MOTOR_NAME)-MsgTxt") {
field(DTYP, "asynOctetRead")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))MOTOR_MESSAGE_TEXT")
field(SCAN, "I/O Intr")
}

# Debug message in IOC log
record(stringout,"$(PREFIX)$(MOTOR_NAME)-DbgStrToLOG") {
record(stringout, "$(PREFIX)$(MOTOR_NAME)-DbgStrToLOG") {
field(DESC, "Log String in IOC log")
field(VAL, "")
field(DTYP, "asynOctetWrite")
Expand All @@ -64,38 +66,34 @@ record(longout, "$(PREFIX)$(MOTOR_NAME)-DIR_") {
field(OUT, "@asyn($(MOTOR_PORT),$(AXIS_NO))MOTOR_REC_DIRECTION")
}

record(ai, "$(PREFIX)$(MOTOR_NAME)-Vel-RB")
{
record(ai, "$(PREFIX)$(MOTOR_NAME)-Vel-RB") {
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))Vel-RB")
field(SCAN, "I/O Intr")
}

record(ai, "$(PREFIX)$(MOTOR_NAME)-Acc-RB")
{
record(ai, "$(PREFIX)$(MOTOR_NAME)-Acc-RB") {
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))Acc-RB")
field(SCAN, "I/O Intr")
}

record(ai, "$(PREFIX)$(MOTOR_NAME)-EncAct")
{
record(ai, "$(PREFIX)$(MOTOR_NAME)-EncAct") {
field(DTYP, "asynFloat64")
field(PREC, "0")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))EncAct")
field(SCAN, "I/O Intr")
}

record(longin, "$(PREFIX)$(MOTOR_NAME)-MR-ErrId")
{
record(longin, "$(PREFIX)$(MOTOR_NAME)-MR-ErrId") {
field(DTYP, "asynInt32")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))ErrId")
field(SCAN, "I/O Intr")
}

record(longout,"$(PREFIX)$(MOTOR_NAME)-ErrRst") {
record(longout, "$(PREFIX)$(MOTOR_NAME)-ErrRst") {
field(DESC, "Error Reset")
field(VAL, 0)
field(DTYP, "asynInt32")
Expand All @@ -104,7 +102,7 @@ record(longout,"$(PREFIX)$(MOTOR_NAME)-ErrRst") {
}

# Motor offset for this axis
record(ao,"$(PREFIX)$(MOTOR_NAME)-OFF_") {
record(ao, "$(PREFIX)$(MOTOR_NAME)-OFF_") {
field(DESC, "$(MOTOR_NAME) offset")
field(DOL, "$(PREFIX)$(MOTOR_NAME).OFF CP MS")
field(OMSL, "closed_loop")
Expand All @@ -115,7 +113,7 @@ record(ao,"$(PREFIX)$(MOTOR_NAME)-OFF_") {


# Motor resolution for this axis
record(ao,"$(PREFIX)$(MOTOR_NAME)-MRES_") {
record(ao, "$(PREFIX)$(MOTOR_NAME)-MRES_") {
field(DESC, "$(MOTOR_NAME) resolution")
field(DOL, "$(PREFIX)$(MOTOR_NAME).MRES CP MS")
field(OMSL, "closed_loop")
Expand All @@ -124,115 +122,115 @@ record(ao,"$(PREFIX)$(MOTOR_NAME)-MRES_") {
field(OUT, "@asyn($(MOTOR_PORT),$(AXIS_NO))MOTOR_REC_RESOLUTION")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgSREV-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgSREV-RB") {
field(DESC, "Micro Steps / Revolution")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgSREV-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgUREV-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgUREV-RB") {
field(DESC, "EGU / Revolution")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgUREV-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgPMIN-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgPMIN-RB") {
field(DESC, "Absolute Minimum")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgPMIN-RB")
field(SCAN, "I/O Intr")
}
record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgPMAX-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgPMAX-RB") {
field(DESC, "Absolute Maximum")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgPMAX-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgSPDB-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgSPDB-RB") {
field(DESC, "Set point dead band window")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgSPDB-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgRDBD-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgRDBD-RB") {
field(DESC, "In target position window")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgRDBD-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgRDBD-Tim-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgRDBD-Tim-RB") {
field(DESC, "In target position time")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgRDBD-Tim-RB")
field(SCAN, "I/O Intr")
}

record(longin,"$(PREFIX)$(MOTOR_NAME)-CfgRDBD-En-RB") {
record(longin, "$(PREFIX)$(MOTOR_NAME)-CfgRDBD-En-RB") {
field(DESC, "In target position enabled")
field(DTYP, "asynInt32")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgRDBD-En-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgPOSLAG-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgPOSLAG-RB") {
field(DESC, "In target position window")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgPOSLAG-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgPOSLAG-Tim-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgPOSLAG-Tim-RB") {
field(DESC, "In target position time")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgPOSLAG-Tim-RB")
field(SCAN, "I/O Intr")
}

record(longin,"$(PREFIX)$(MOTOR_NAME)-CfgPOSLAG-En-RB") {
record(longin, "$(PREFIX)$(MOTOR_NAME)-CfgPOSLAG-En-RB") {
field(DESC, "In target position enabled")
field(DTYP, "asynInt32")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgPOSLAG-En-RB")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgDHLM-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgDHLM-RB") {
field(DESC, "EC High Soft Limit RB")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgDHLM")
field(SCAN, "I/O Intr")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-CfgDLLM-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgDLLM-RB") {
field(DESC, "EC Low Soft Limit RB")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgDLLM")
field(SCAN, "I/O Intr")
}

record(longin,"$(PREFIX)$(MOTOR_NAME)-CfgDHLM-En-RB") {
record(longin, "$(PREFIX)$(MOTOR_NAME)-CfgDHLM-En-RB") {
field(DESC, "EC High Soft Limit enabled RB")
field(DTYP, "asynInt32")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgDHLM-En")
field(SCAN, "I/O Intr")
}

record(longin,"$(PREFIX)$(MOTOR_NAME)-CfgDLLM-En-RB") {
record(longin, "$(PREFIX)$(MOTOR_NAME)-CfgDLLM-En-RB") {
field(DESC, "EC Low Soft Limit enabled RB")
field(DTYP, "asynInt32")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgDLLM-En")
Expand All @@ -241,41 +239,37 @@ record(longin,"$(PREFIX)$(MOTOR_NAME)-CfgDLLM-En-RB") {

# Config records, the values will be pushed into the motor record fields

record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgVELO-RB")
{
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgVELO-RB") {
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgVELO")
field(SCAN, "I/O Intr")
}

record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgVMAX-RB")
{
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgVMAX-RB") {
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgVMAX")
field(SCAN, "I/O Intr")
}


record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgJVEL-RB")
{
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgJVEL-RB") {
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgJVEL")
field(SCAN, "I/O Intr")
}

record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgACCS-RB")
{
record(ai, "$(PREFIX)$(MOTOR_NAME)-CfgACCS-RB") {
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))CfgACCS")
field(SCAN, "I/O Intr")
}

record(mbbi,"$(PREFIX)$(MOTOR_NAME)-HomProc-RB") {
field(DESC,"Homing procedure")
record(mbbi, "$(PREFIX)$(MOTOR_NAME)-HomProc-RB") {
field(DESC, "Homing procedure")
field(DTYP, "asynInt32")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))HomProc-RB")
field(SCAN, "I/O Intr")
Expand Down Expand Up @@ -314,44 +308,43 @@ record(mbbi,"$(PREFIX)$(MOTOR_NAME)-HomProc-RB") {
field(FFST, "ManSetPos")
}

record(ai,"$(PREFIX)$(MOTOR_NAME)-HomPos-RB") {
record(ai, "$(PREFIX)$(MOTOR_NAME)-HomPos-RB") {
field(DESC, "Home Position")
field(DTYP, "asynFloat64")
field(PREC, "$(PREC)")
field(INP, "@asyn($(MOTOR_PORT),$(AXIS_NO))HomPos-RB")
field(SCAN, "I/O Intr")
}

record (asyn, "$(PREFIX)$(MOTOR_NAME)-$(MOTOR_PORT)-asyn")
{
record (asyn, "$(PREFIX)$(MOTOR_NAME)-$(MOTOR_PORT)-asyn") {
}

record(calcout,"$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgH2L"){
record(calcout, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgH2L"){
#field(PINI, "1")
field(DESC, "Trigg MR Sync")
field(SCAN, "Passive")
field(INPA, "$(PREFIX)$(MOTOR_NAME)-SumIlockBwd CP")
field(INPB, "$(PREFIX)$(MOTOR_NAME)-SumIlockFwd CP")
field(INPC, "1")
field(CALC, "A && B")
field(OCAL, "C")
field(DOPT, "Use OCAL")
field(OOPT, "Transition To Zero")
field(OUT, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgSeq PP")
}

record(calcout,"$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgL2H"){
field(DESC, "Trigg MR Sync")
field(SCAN, "Passive")
field(INPA, "$(PREFIX)$(MOTOR_NAME)-SumIlockBwd CP")
field(INPB, "$(PREFIX)$(MOTOR_NAME)-SumIlockFwd CP")
field(INPC, "1")
field(CALC, "A && B")
field(OCAL, "C")
field(DOPT, "Use OCAL")
field(OOPT, "Transition To Zero")
field(OUT, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgSeq PP")
}

record(calcout, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgL2H"){
#field(PINI, "1")
field(DESC, "Trigg MR Sync")
field(SCAN, "Passive")
field(INPA, "$(PREFIX)$(MOTOR_NAME)-SumIlockBwd CP")
field(INPB, "$(PREFIX)$(MOTOR_NAME)-SumIlockFwd CP")
field(INPC, "1")
field(CALC, "A && B")
field(OCAL, "C")
field(DOPT, "Use OCAL")
field(OOPT, "Transition To Non-zero")
field(OUT, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgSeq PP")
field(DESC, "Trigg MR Sync")
field(SCAN, "Passive")
field(INPA, "$(PREFIX)$(MOTOR_NAME)-SumIlockBwd CP")
field(INPB, "$(PREFIX)$(MOTOR_NAME)-SumIlockFwd CP")
field(INPC, "1")
field(CALC, "A && B")
field(OCAL, "C")
field(DOPT, "Use OCAL")
field(OOPT, "Transition To Non-zero")
field(OUT, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgSeq PP")
}

record(seq, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgSeq") {
Expand All @@ -375,9 +368,9 @@ record(seq, "$(PREFIX)$(MOTOR_NAME)-MR-SyncTrgSeq") {
}

record(seq, "${PREFIX}${MOTOR_NAME}-StpCmd_") {
field(DESC, "Stop Axis")
field(DOL1, "${PREFIX}${MOTOR_NAME}-StpCmd CP")
field(DO2, "1")
field(LNK1, "")
field(LNK2, "${PREFIX}${MOTOR_NAME}.STOP PP")
field(DESC, "Stop Axis")
field(DOL1, "${PREFIX}${MOTOR_NAME}-StpCmd CP")
field(DO2, "1")
field(LNK1, "")
field(LNK2, "${PREFIX}${MOTOR_NAME}.STOP PP")
}
Loading
Loading