# Envelope - Rule 5-42 | ||
**Schema Version:** 0.0.37 | ||
**Mandatory Rule:** False | ||
**Rule ID:** 5-42 | ||
|
||
**Rule Description:** Each linear thermal bridge and point thermal bridge as identified in Section 5.5.5 shall be modeled using either of the following techniques: | ||
|
||
a. A separate model of the assembly within the energy simulation model. | ||
b. Adjustment of the clear-field U-factor in accordance with Section A10.2. | ||
|
||
**Rule Assertion:** B-RMR = expected value | ||
**Appendix G Section:** Table G3.1 Section 5(a)-1 Proposed | ||
**Appendix G Section Reference:** 5(a) | ||
**Data Lookup:** None | ||
**Evaluation Context:** Evaluate each Project | ||
|
||
**Applicability Checks:** | ||
|
||
1. A project has an exterior wall | ||
|
||
**Function Call:** | ||
|
||
**Manual Check:** Ensure that linear and point thermal bridges, as identified in Section 5.5.5 are modeled using either of the following techniques: | ||
a. A separate model of the assembly within the energy simulation model. | ||
b. Adjustment of the clear-field U-factor in accordance with Section A10.2. | ||
|
||
**Rule Logic:** | ||
**Applicability:** | ||
- look at each zone in the RMD: `for zone in P_RMD....zones:` | ||
- look at each surface in the zone: `for surface in zone.surfaces:` | ||
- if the surface is an exterior surface, then this rule is applicable for the entire project: `if((surface.adjacent_to == "EXTERIOR") or (surface.adjacent_to == "GROUND")): UNDETERMINED` | ||
- if the rule logic gets here without an UNDETERMINED outcome, then the project is not applicable: `NOT_APPLICABLE` | ||
|
||
|
||