The up-to-date version of this documentation is now on the Tvheadend website at https://docs.tvheadend.org/documentation/development/json-api
Lists statistics of input sources and connections. ADMIN privilege is required for all these functions.
Lists currently-connected client devices.
{
"totalCount" : 1,
"entries" : [
{
"id" : 1,
"started" : 1508668447,
"server_port" : 9982,
"server" : "x.x.x.x",
"type" : "HTSP",
"peer" : "x.x.x.y",
"user" : "xxxxxx",
"peer_port" : 57496
}
]
}
Lists currently-active subscriptions.
{
"entries" : [
{
"errors" : 0,
"title" : "epggrab",
"in" : 85222,
"total_in" : 25162474,
"total_out" : 25162474,
"id" : 75,
"out" : 85222,
"service" : "Silicon Labs Si2168 : DVB-T #0/Sandy/690MHz/Raw PID Subscription",
"state" : "Running",
"start" : 1508763840
}
],
"totalCount" : 1
}
Lists statistics of input devices.
For DVB-T and DVB-S tuners at least, the signal and SNR values are only non-zero while TVH is actively using the device. Some items may be missing if the device is idle.
{
"entries" : [
{
"ec_block" : 0,
"uuid" : "20f11bcaaf93afb5fc13cce31278494e",
"signal_scale" : 2,
"weight" : 100,
"cc" : 1,
"ber" : 0,
"tc_block" : 0,
"input" : "Montage Technology M88DS3103 #0 : DVB-S #0",
"tc_bit" : 0,
"unc" : 0,
"te" : 0,
"bps" : 2257504,
"subs" : 1,
"ec_bit" : 0,
"pids" : [
0,
1,
16,
17,
18,
269,
5700,
5701,
5703,
5704
],
"stream" : "10773H in DVB-S Network",
"snr" : 14149,
"signal" : -75649,
"snr_scale" : 2
}
],
"totalCount" : 1
}
The meaning of the statistics is below. Not all input sources provide all of the values.
ber | Bit Error Rate |
bps | Bandwidth (bits/second) |
cc | Continuity Errors |
ec_bit | Bit Error Count |
ec_block | Block Error Count |
pids | List of pids present in the stream |
signal | Signal Strength (see below) |
signal_scale | See below |
snr | Signal/Noise Ratio (see below) |
snr_scale | See below |
stream | Stream (multiplex) name |
subs | Subscribers |
tc_bit | Total Bit Error Count |
tc_block | Total Block Error Count |
te | Transport Errors |
unc | Uncorrected Blocks |
weight | Weight |
For signal_scale and snr_scale, a value of 1 indicates that the corresponding signal or SNR reading is relative; 65535 = 100%. A value of 2 indicates the reading is absolute; 1000 = 1dB. A value of 0 indicates that the reading is not available or not valid.
The "pids" data is only present in TVH versions 4.3.1420 and later.
Resets the input counters to zero.
-
uuid
The uuid of the input device from status/inputs. More than one uuid can be specified - syntax?
Disconnects one or more clients.
-
id